Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
COMPLETED
153 participants
OBSERVATIONAL
2018-07-23
2018-11-21
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
FreeStyle Libre Flash Glucose Monitoring System Accuracy Study
NCT03141892
FreeStyle Libre Flash Accuracy Study
NCT03257501
FreeStyle Libre Continuous Glucose Monitoring System Accuracy Study
NCT04464772
FreeStyle Libre Flash Glucose Monitoring System Accuracy
NCT03159546
FreeStyle Libre Flash Glucose Monitoring System Post Approval Study
NCT03448380
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
COHORT
PROSPECTIVE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
Diabetes Mellitus Type 1 and Type 2
Subjects will wear the Abbott Sensor Based Glucose Monitoring Systems and expected to perform at least 8 capillary BG test per day. Site Staff will determine when subject will undergo either a hypoglycemia induction or a hyperglycemia induction. Study staff will perform IV blood draw to obtain blood plasma for YSI sampling every 15 min when glucose as measured by YSI is above 70mg/dL and below 240 mg/dL.
Freestyle Libre Flash Glucose Monitoring System
Subjects will wear the Abbott Sensor based FreeStyle Libre Flash Glucose Monitoring System and will receive no treatment except for safety purposes
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
Freestyle Libre Flash Glucose Monitoring System
Subjects will wear the Abbott Sensor based FreeStyle Libre Flash Glucose Monitoring System and will receive no treatment except for safety purposes
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
* Subject must have type 1 or type 2 diabetes.
* Subject must require insulin therapy through an insulin pump and/or multiple daily insulin injections (at least 3 injections daily).
* Willing to perform a minimum of 8 finger sticks per day while wearing the sensor in the study.
* Subject must be able to read and understand English.
* Willing to have their blood sugar manipulated during in-clinic sessions.
* In the investigator's opinion, the subject must be able to follow the instructions provided to him/her by the study site and perform all study tasks as specified by the protocol.
* At the time of enrollment, subject must be available to participate in all study visits.
* Subject must be willing and able to provide written signed and dated informed consent.
* Additional criteria for hypoglycemia induction.
* Known insulin sensitivity factor.
Exclusion Criteria
* Subject has known allergy to medical grade adhesive or isopropyl alcohol used to disinfect skin.
* Subject is pregnant, attempting to conceive or not willing and able to practice birth control during the study duration (applicable to female subjects only).
* Subject has extensive skin changes/diseases at the proposed application sites that could interfere with device placement or the accuracy of interstitial glucose measurements. Such conditions include, but are not limited to extensive psoriasis, recent burns or severe sunburn, extensive eczema, extensive scarring, dermatitis herpetiformis, skin lesions, redness, infection or edema.
* Subject has had an episode of severe hypoglycemia requiring intervention from a health care professional (i.e. EMT assistance, emergency room visit, or hospital admission) within the last three (3) months.
* Subject is currently participating in another clinical trial.
* Subject has donated blood within 112 days (3.7 months) prior to the beginning of the study activities.
* Subject has both hemoglobin (Hb) and hematocrit levels that are 10% or more below the normal ranges (For reference low end of the normal range for Hb for males is 14 g/dL and for females is 12 g/dL; low end of the normal hematocrit is 40% for men and 36% for women).
* Subject has concomitant medical condition which, in the opinion of the investigator, could present a risk to the safety or welfare of the subject or study staff. Such conditions include but are not limited to:
* History of HIV, Hepatitis B or C
* Subject has X-ray, MRI, CT or diathermy appointment scheduled during the period of study participation, and the appointment cannot be rescheduled for a time before study participation starts or after study participation ends.
* Subject is unsuitable for participation due to any other cause as determined by the Investigator.
18 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Abbott Diabetes Care
INDUSTRY
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
Shridhara Karinka, PhD
Role: STUDY_DIRECTOR
Abbott Diabetes Care
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
AMCR
Escondido, California, United States
Sansum Diabetes Research Institute
Santa Barbara, California, United States
Diablo Clinical Research
Walnut Creek, California, United States
Rocky Mountain Diabetes and Osteoporosis Center
Idaho Falls, Idaho, United States
Rainier Clinical Research Center
Renton, Washington, United States
Countries
Review the countries where the study has at least one active or historical site.
References
Explore related publications, articles, or registry entries linked to this study.
Alva S, Bailey T, Brazg R, Budiman ES, Castorino K, Christiansen MP, Forlenza G, Kipnes M, Liljenquist DR, Liu H. Accuracy of a 14-Day Factory-Calibrated Continuous Glucose Monitoring System With Advanced Algorithm in Pediatric and Adult Population With Diabetes. J Diabetes Sci Technol. 2022 Jan;16(1):70-77. doi: 10.1177/1932296820958754. Epub 2020 Sep 19.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
ADC-US-VAL-18174
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.