Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
UNKNOWN
NA
100 participants
INTERVENTIONAL
2022-08-17
2024-04-30
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
• If the use of CGM with alarms is safe and effective for managing low and/or high blood sugars when compared with performing finger sticks several times per day
Participants will wear one or two FreeStyle Libre CGM sensors for 12-14 days three times over a 12-week (3 month) period. This means that they will have the one to two sensors inserted under their skin. They will be asked to come to the study site four times and complete two phone calls with research staff over the 12-week period.
Researchers will compare the LibreView CGM group to the Standard of Care group to see if the use of continuous glucose monitoring (CGM) reduces risk of low blood sugar in patients with type 2 diabetes (T2D) after hospital discharge when compared with the current standard method.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Effect of the FreeStyle Libre 2 Flash Glucose Monitoring System on Hyperglycemia in People With T2 Diabetes
NCT04604093
Freestyle Libre Flash Glucose Monitoring System
NCT03607448
FreeStyle Libre Monitoring in T2DM
NCT05597293
Type 2 Diabetes Glucose Biomarker Study With a Continuous Glucose Monitoring System
NCT04529239
CGM Use in Adults With Type 2 Diabetes on Basal Insulin
NCT05944432
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
In this study, we will compare the CGM method to the current usual (standard-of-care) method, which involves taking blood samples by fingerstick before meals and at bedtime. The CGM system recognizes low and high blood sugars throughout the day and night. The CGM system used in this study also has an alarm feature that alerts the user if blood sugar levels are too high or too low. In this study we will test if the use of CGM with alarms is safe and effective for managing low and/or high blood sugars when compared with performing finger sticks several times per day, which some diabetes patients find painful and burdensome.
In this study, 50% of participants will use the CGM method and 50% will use the fingerstick method to measure and control their glucose. The researchers will compare the two groups to answer the question if the use of continuous glucose monitoring (CGM) reduces risk of low blood sugar in patients with type 2 diabetes (T2D) after hospital discharge when compared with the current standard method.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
RANDOMIZED
PARALLEL
PREVENTION
NONE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
FreeStyle Libre 2
Subjects randomized to Group 1: FreeStyle Libre 2 will wear two FreeStyle Libre CGM sensors for 12-14 days three times over a 12-week (3 month) period. They will have two sensors inserted under their skin:
FreeStyle Libre 2 sensor with display on, meaning they will be able to see their blood sugar values on the mobile application or a reader.
FreeStyle Libre Pro sensor is used without mobile application or reader. This sensor is place as a backup in case the information is missing from the Libre 2 sensor.
FreeStyle Libre 2 CGM
FreeStyle Libre 2 CGM is FDA-approved and will be used according to FDA-approved labeling
FreeStyle Libre Pro blinded CGM
FreeStyle Libre Pro blinded CGM is FDA-approved and will be used according to FDA-approved labeling
Point of Care (POC) Self-Monitoring of Blood Glucose (SMBG) testing
Subjects randomized to Group 2: Point of Care (POC) Self-Monitoring of Blood Glucose (SMBG) testing will wear one FreeStyle Libre Pro CGM sensor without using the mobile application or reader (blinded). These subjects will have the one sensor inserted under their skin but you will not see sugar values on the CGM. Subjects will wear the CGM for 12-14 days three times over a 12-week (3 month) period but will not use the CGM to monitor and control their blood sugar. Instead, they will monitor their sugar values by the standard method of fingerstick before each meal and at bedtime.
FreeStyle Libre Pro blinded CGM
FreeStyle Libre Pro blinded CGM is FDA-approved and will be used according to FDA-approved labeling
FreeStyle Precision Neo blood glucose meter
FreeStyle Precision Neo blood glucose meter is FDA-approved and will be used according to FDA-approved labeling
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
FreeStyle Libre 2 CGM
FreeStyle Libre 2 CGM is FDA-approved and will be used according to FDA-approved labeling
FreeStyle Libre Pro blinded CGM
FreeStyle Libre Pro blinded CGM is FDA-approved and will be used according to FDA-approved labeling
FreeStyle Precision Neo blood glucose meter
FreeStyle Precision Neo blood glucose meter is FDA-approved and will be used according to FDA-approved labeling
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
* 2\. Known history of T2D treated with oral antidiabetic agents (sulfonylureas, meglitinides, alpha-glucosidase inhibitors, thiazolidinedione, DPP-4 inhibitors, SGLT2- inhibitors), GLP1-RAs (exenatide, liraglutide, dulaglutide, semaglutide) or insulin therapy (human regular or rapid-acting analogs or ultra-rapid analogs \[ lispro, aspart, glulisine, fast acting insulin aspart, insulin lispro\]), intermediate acting (NPH and premixed formulations) or long-acting basal (glargine, detemir, degludec) formulations.
* 3\. Discharged on insulin therapy consisting of basal therapy 1) with or without bolus insulin and also 2) with or without other diabetes drugs.
Exclusion Criteria
* 2\. Subjects using CGM technology prior to admission
* 3\. Subjects with type 1 diabetes
* 4\. Subjects not willing to receive insulin injections or test POC 4 times daily
* 5\. Subjects discharged from the hospital on diabetes therapy that does not include basal insulin.
* 6\. Subjects not willing to wear a CGM device
* 7\. Pregnant women
* 8\. Subjects with clinically relevant hepatic disease (diagnosed liver cirrhosis and portal hypertension) and end-stage kidney disease (eGFR\< 30 ml/min), dialysis, critically ill or terminal illness.
* 9\. Subjects with history of cognitive impairment, dementia, or mental condition rendering the subject unable to understand the nature and consequences of the study.
* 10\. Subjects expected to be readmitted to the hospital within 3 months post-discharge.
18 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Abbott Diabetes Care
INDUSTRY
Emory University
OTHER
Palo Alto Medical Foundation
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
David Klonoff, MD
Role: PRINCIPAL_INVESTIGATOR
Sutter Health, Diabetes Research Institute
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Palo Alto Medical Foundation Research Institute
Palo Alto, California, United States
Division of Endocrinology, Department of Medicine, Emory University School of Medicine
Atlanta, Georgia, United States
Countries
Review the countries where the study has at least one active or historical site.
Central Contacts
Reach out to these primary contacts for questions about participation or study logistics.
Facility Contacts
Find local site contact details for specific facilities participating in the trial.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
2022.050-2
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.