The EXPLORE Study - The Use of Binocular OCT Imaging for the Assessment of Ocular Disease
NCT ID: NCT03553017
Last Updated: 2020-10-19
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
COMPLETED
70 participants
OBSERVATIONAL
2018-05-22
2020-03-01
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Binocular OCT extends the application of OCT devices beyond that of simple, cross- sectional imaging to a diverse array of diagnostic tests. The binocular design also removes the need for additional personnel to perform testing (i.e., the device can be self-operated in an automated manner), and allows for novel testing to be performed that is not possible with monocular imaging. In particular, binocular OCT devices have the potential to perform automated, quantitative pupillary measurements - an entirely novel application for this imaging modality, plus also adds a number of unique capabilities. In particular, binocular OCT removes the need for additional personnel to acquire the images by enabling patients to align the optical axes of the instrument with the optical axes of their own eyes. The system also employs recently developed "swept-source" lasers as its light source, allowing it to see deeper into the eye than conventional OCT systems. Finally, binocular OCT systems allow image capture from both eyes at the same time. This "simultaneous" ocular imaging extends the range of diagnostic testing possible, allowing for features such as pupillometry and ocular motility.
The greatly increased range of imaging for these lasers enables the entire depth of eye tissue to be captured in just a few sequences of images - so- called "whole eye" OCT or "OCT ophthalmoscopy".
In this study, the investigators aim to explore the unique imaging features of the binocular OCT to describe novel features across a range of diseases. The repeatability of quantifying various parameters in the images acquired using the system will be assessed.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Imaging Lens Deposits in Exfoliation Syndrome
NCT02042703
OCT Technology Development to Assess Ocular Integrity and Characterize Ocular Integrity and Intraocular Scatterers
NCT03531853
OCT Angiography in Wet AMD
NCT02253030
Quantification & Classification of Inflammatory Cells in Uveitis Using OCT
NCT07065747
Home OCT Guided Management Study of Subjects Diagnosed With Neovascular-AMD
NCT05650047
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
Most OCT systems are dedicated to retinal imaging or anterior segment imaging. Some commercial retinal scanners are capable of switching between anterior and posterior imaging modes with additional optical attachments, however anterior segment imaging performance is typically suboptimal in these instruments. A key feature of the Binocular OCT is that it can perform 'whole-eye' OCT imaging spanning from the eyelids to the posterior pole in a single instrument without the requirement of additional attachments, and in an automated way.
This study will determine whether the instrument can be used for patients with different eye diseases. The investigators anticipate recruiting approximately 100 participants with anterior eye conditions such as keratoconus, acute anterior uveitis, and pigment dispersion syndrome, in addition to approximately 100 participants with posterior segment eye conditions such as diabetic retinopathy, age-related macular degeneration, and glaucoma.
As this device can image many structures of the eye and with a greater depth range than most commercial OCT devices, it may be possible to visualise features not previously imaged with other devices such as vitreous imaging, or imaging of cells in the ocular inflammatory conditions. In this study, the prototype binocular OCT system will be used to describe novel features across a range of ocular diseases. Qualitative analyses of raw binocular OCT images will be performed (including assessments of retinal pathological features, corneal and anterior chamber morphology, lens status, iris dynamics, and ocular inflammatory cells). These parameters will be correlated with findings from other non-invasive ocular imaging previously obtained during routine clinical care. Although raw OCT images can be useful for diagnosis, quantitative data from the images are useful to monitor eye disease. Commercial OCT devices have built-in software packages to analyse OCT images to provide the clinician with parameters for detecting and monitoring eye disease. Quantitative analysis of binocular OCT images will be performed using MATLAB (The MathWorks, Inc., Natick, Massachusetts, United States).
In addition, the ability to combine structural and functional assessments in the same instrument may permit better examinations of ophthalmic disease compared to separate clinical tests. This study will also permit future studies to be correctly powered.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
CASE_ONLY
CROSS_SECTIONAL
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
Participants with eye disease
A maximum of 200 participants with various eye diseases will be recruited from appropriate eye clinics at Moorfields Eye Hospital. Eye conditions will include both anterior segment disease such as corneal disease and ocular inflammatory disease, retinal vascular and macular diseases, and optic nerve disease such as glaucoma.
Binocular OCT
Participants in the study will undergo OCT imaging using a prototype binocular OCT imaging system (Envision Diagnostics, Inc., CA) twice to assess repeatability.).
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
Binocular OCT
Participants in the study will undergo OCT imaging using a prototype binocular OCT imaging system (Envision Diagnostics, Inc., CA) twice to assess repeatability.).
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
* Male or female, aged 18 years or older
* Ability to understand nature/purpose of the study and to provide informed consent
* Ability to undergo binocular OCT imaging
* Ability to follow instructions and complete the study
* Ability to speak English
Exclusion Criteria
* Hearing impairment sufficient to interfere with hearing instructions
* Any condition which, in the investigator's opinion, would conflict or otherwise prevent the subject from complying with the required procedures, schedule, or other study conduct
18 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
National Institute for Health Research, United Kingdom
OTHER_GOV
University College, London
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Moorfields Eye Hospital NHS FT
London, , United Kingdom
Countries
Review the countries where the study has at least one active or historical site.
References
Explore related publications, articles, or registry entries linked to this study.
Chopra R, Mulholland PJ, Dubis AM, Anderson RS, Keane PA. Human Factor and Usability Testing of a Binocular Optical Coherence Tomography System. Transl Vis Sci Technol. 2017 Aug 15;6(4):16. doi: 10.1167/tvst.6.4.16. eCollection 2017 Jul.
Walsh AC. Binocular optical coherence tomography. Ophthalmic Surg Lasers Imaging. 2011 Jul;42 Suppl:S95-S105. doi: 10.3928/15428877-20110627-09.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
17/0839
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.