Validation of Criteria for Identification of Epileptiform Discharges in EEG Recordings of Patients With Epilepsy

NCT ID: NCT03533374

Last Updated: 2020-07-22

Study Results

Results available

Outcome measurements, participant flow, baseline characteristics, and adverse events have been published for this study.

View full results

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

COMPLETED

Total Enrollment

100 participants

Study Classification

OBSERVATIONAL

Study Start Date

2012-01-01

Study Completion Date

2018-01-01

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

Electroencephalography (EEG) records electric activity of the brain using electrodes placed on the scalp. EEG is an important tool in the diagnostic work-up of patients with epilepsy. Specific types of sharp EEG discharges (epileptiform discharges) are associated with patients with epilepsy.

The International Federation of Clinical Neurophysiology (IFCN) has recently published a set of six operational criteria for identifying epileptiform discharges. At least four criteria need to be present in order to classify a discharge as epileptiform. These criteria are largely based on expert opinion and have not been validated yet. It is not clear what the sensitivity and specificity of these criteria are, and which combination of these criteria are optimal. Each criterion is based on visual assessment. However, it is not known what the inter-rater agreement of these criteria are.

EEG is traditionally inspected in sensor space, i.e. in the recording channels. Advances in signal analysis made possible reconstructing the electric currents in the regions of the brain generating them, and displaying the signals in the source space, instead of the sensor space.

The objectives of this study are: to determine the inter-rater agreement of the IFCN criteria by visual analysis in sensor space, to determine the combination of criteria with the best accuracy (sensitivity and specificity) and assess the accuracy of evaluating the discharges in source space.

The raters will analyze EEG recordings from 100 patients, from two groups: consecutive patients with epilepsy and consecutive patients with non-epileptic paroxysmal episodes. EEG was recorded during long-term video-EEG monitoring. As reference standard, the investigators used the evaluation of the patients´ habitual clinical episode. The performance of the criteria in sensor-space and the analysis in source space will be compared with the unrestricted expert scorings.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

Epilepsy affects 50 million people of all ages. It is the most common neurologic disorder across the lifespan, and has been found to be associated with an increased risk of mortality compared to the general population.

EEG is an important tool in the diagnostic work-up of patients with suspected epilepsy. The presence of epileptiform EEG discharges (EDs) confirm the diagnosis and provides important information that helps in classifying epilepsy.

EDs are visually identified by experts with training in reading EEG. Although EDs were defined in the previous edition of the IFCN glossary of terms, that definition was conceptual, and the inter-rater agreement for identifying EDs was only moderate. Recently, the IFCN suggested the following operational definition for EDs: Transients distinguishable from background activity with a characteristic morphology; EDs have to fulfill at least 4 of the following 6 criteria:

1. Di- or tri-phasic waves with sharp or spiky morphology (i.e. pointed peak).
2. Different wave-duration than the ongoing background activity: either shorter or longer.
3. Asymmetry of the waveform: a sharply rising ascending phase and a more slowly decaying descending phase, or vice versa.
4. The transient is followed by an associated slow after-wave.
5. The background activity surrounding epileptiform discharges is disrupted by the presence of the epileptiform discharges.
6. Distribution of the negative and positive potentials on the scalp suggests a source of the signal in the brain, corresponding to a radial, oblique or tangential orientation of the source. This is best assessed by inspecting voltage maps constructed using common-average reference.

However, these criteria are largely based on expert opinion. Data from clinical validation studies are lacking, thus it is not known what the sensitivity and specificity of these methods are. The threshold of four fulfilled criteria was arbitrary, and it is not sure whether it yields the optimal accuracy (sensitivity and specificity). Furthermore, since each criterion is based on visual evaluation, it is not known whether all experts would reach the same conclusion.

The IFCN criteria were developed for identifying EDs using the traditional way of inspecting EEG, in the channels of the recording electrodes (sensor space). However, advances in signal analysis made possible to reproduce the electric currents in the brain regions, using a spatial filtering method (source space).

The objective of this study are:

1. To determine the inter-rater agreement for the IFCN criteria
2. To determine the number of criteria and their combination that yields the highest diagnostic accuracy
3. To determine the accuracy of identifying EDs in source space. Raters with experience in clinical EEG will inspect 100 anonymized EEG samples, from consecutive patients with epilepsy and consecutive patients with non-epileptic paroxysmal episodes. All 100 patients have a reference standard for their condition, derived from analysis of their video-EEG recordings of their habitual clinical episode. Patients with both focal and generalized epilepsy, as well as non-epileptic paroxysmal episodes (psychogenic non-epileptic seizures, sleep-disorders, movement disorders, convulsive syncope) are included.

Each EEG sample contains a sharp transient that is either epileptiform or not. EEGs were recoded using the IFCN electrode array of 25 electrodes (including the ones in the inferior temporal chain).

The samples were randomized twice, resulting in two series containing the same set of 100 samples, though with different codes and in different order of presentation. The raters will inspect the two series separately. In the first session the raters will inspect samples in sensor space, using traditional EEG montages (longitudinal and transversal bipolar; common average) and voltage maps. For each sample, they will score the presence or absence of each IFCN criterion. In the second session, the raters will inspect the EEG samples in source space and voltage maps, and will conclude on the presence / absence of EDs.

The performance of these methods will be compared with unrestricted scorings based on the experts´ evaluation.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Epilepsy Non-Epileptic Seizure

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Observational Model Type

CASE_CONTROL

Study Time Perspective

RETROSPECTIVE

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

Patients with epileptic seizures

Electroencephalogram (EEG) and visual evaluation

\- Electroencephalogram (EEG) was recorded using Nicolet-One system, and the standard 25-electrode array. Recordings with sharp transients are inspected by experts (physicians).

Electroencephalogram (EEG) and visual evaluation

Intervention Type DIAGNOSTIC_TEST

Electroencephalogram (EEG) was recorded using Nicolet-One system, and the standard 25-electrode array. Recordings with sharp transients are inspected by experts (physicians).

Patients with non-epileptic seizures

Electroencephalogram (EEG) and visual evaluation

\- Electroencephalogram (EEG) was recorded using Nicolet-One system, and the standard 25-electrode array. Recordings with sharp transients are inspected by experts (physicians).

Electroencephalogram (EEG) and visual evaluation

Intervention Type DIAGNOSTIC_TEST

Electroencephalogram (EEG) was recorded using Nicolet-One system, and the standard 25-electrode array. Recordings with sharp transients are inspected by experts (physicians).

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

Electroencephalogram (EEG) and visual evaluation

Electroencephalogram (EEG) was recorded using Nicolet-One system, and the standard 25-electrode array. Recordings with sharp transients are inspected by experts (physicians).

Intervention Type DIAGNOSTIC_TEST

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

1. Patients who underwent long-term video-EEG monitoring
2. Patients who had at least one habitual episode (seizure) recorded on video and EEG.
3. Patients with sharp transients.
4. For patients with epilepsy: the interictal (epileptiform) sharp transients are concordant with the ictal recording

Exclusion Criteria

Patients with both epileptic seizures and non-epileptic seizures (paroxysmal episodes).
Eligible Sex

ALL

Accepts Healthy Volunteers

No

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

Aarhus University Hospital

OTHER

Sponsor Role collaborator

Central Denmark Region

OTHER

Sponsor Role collaborator

Filadelfia Epilepsy Hospital

OTHER

Sponsor Role collaborator

University Health Network, Toronto

OTHER

Sponsor Role collaborator

University Hospital Erlangen

OTHER

Sponsor Role collaborator

Oslo University Hospital

OTHER

Sponsor Role collaborator

Sándor Beniczky

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Sándor Beniczky

professor

Responsibility Role SPONSOR_INVESTIGATOR

Provided Documents

Download supplemental materials such as informed consent forms, study protocols, or participant manuals.

Document Type: Study Protocol

View Document

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

CIED

Identifier Type: -

Identifier Source: org_study_id

More Related Trials

Additional clinical trials that may be relevant based on similarity analysis.

Acoustic Stimulation for Seizure Suppression
NCT03198494 ENROLLING_BY_INVITATION NA
Brain Activity in Epilepsy
NCT05307146 RECRUITING NA