RAM Cannula Versus Short Bi-nasal Cannula in Respiratory Distress Syndrome

NCT ID: NCT03366714

Last Updated: 2020-02-19

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

COMPLETED

Clinical Phase

NA

Total Enrollment

100 participants

Study Classification

INTERVENTIONAL

Study Start Date

2017-04-01

Study Completion Date

2018-08-15

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

Noninvasive ventilation defines methods of providing ventilation support with constant or variable pressure using nasal or nasopharyngeal interfaces without endotracheal intubation or tracheostomy. Today, short binasal prongs and different types of nasal masks are the most commonly used nasal interfaces in the NICU with the aim of providing NIV.

RAM cannula (Neotech ™, Valencia, CA), a new nasal interface, is increasingly used in NID applications in newborn infants. The RAM cannula is available in the inspiration and expiration arms of the stroke while reducing the dead space in the respiratory tract due to the low nasal prong diameter. There are not enough studies comparing the effectiveness of the RAM cannula with other short binasal prongs or nasal masks.

Investigators compared the effectiveness and nasal injury rates of RAM cannula and short binasal prong as NIV interfaces in preterm infants.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

In the past years endotracheal intubation and mechanical ventilation with surfactant therapy was the standard treatment of moderate to severe respiratory distress syndrome (RDS). Especially in the last 10 years, prolonged intubation and positive pressure ventilation have been shown to increase the frequency of bronchopulmonary dysplasia, a kind of chronic pulmonary disease. Intubation and positive pressure ventilation cause volu-trauma, baro-trauma, and alveolar secondary to bio-trauma, leading to excessive distension and inflammation, disrupting alveolar formation, resulting in fibrosis and bronchopulmonary dysplasia. Intubation and mechanical ventilation also involve ventilator-associated pneumonia. For this reason, strategies for lung protective ventilation have become increasingly widespread in recent years and noninvasive ventilation (NNV) applications without endotracheal intubation have become the first choice in neonatal ventilation.

Noninvasive ventilation defines methods of providing ventilation support with constant or variable pressure using nasal or nasopharyngeal interfaces without endotracheal intubation or tracheostomy. Noninvasive ventilation can be performed in a variety of forms such as continuous positive airway pressure (NCPAP) nasal intermittent positive-pressure ventilation (NIPPV) and high-flow nasal cannulae.

Different nasal interfaces are used to provide noninvasive ventilation support. For this purpose, there is no standard apparatus used in neonatal intensive care units (NICU). Nasopharyngeal cannulae are not currently recommended for use with NIV because they cause extensive resistance during spontaneous breathing, nasopharyngeal area damage and colonization, although they have been widely used in previous years. Today, short binasal prongs and different types of nasal masks are the most commonly used nasal interfaces in the NICU with the aim of providing NIV. Nasal interfaces are recommended to be placed on the surface without causing pressure loss. For this purpose, hoods and fixing apparatus are frequently used. For this reason, babies often become restless and agitated during NIV applications. In addition, necrosis and deformities may develop in septum due to pressure of nasal septum.

RAM cannula (Neotech ™, Valencia, CA), a new nasal interface, is increasingly used in NID applications in newborn infants. RAM seems ideal to allow effective and cranium development in the prevention of pressure damage to the face due to the design of the cannula and the need for head or face access to detect it. The RAM cannula is available in the inspiration and expiration arms of the stroke while reducing the dead space in the respiratory tract due to the low nasal prong diameter. Although the use of RAM cannula as a NIV interface in newborn intensive care units is becoming increasingly widespread, the number of studies related to RAM cannula is limited. Most of the studies investigating the effectiveness of this interface were made on artificial lung models. In the study of "Mukerji" and colleagues, the short binasal prong and RAM cannula were compared as interfaces in NIPPV application in the artificial lung model and it was found that carbon dioxide excretion in short binasal prongs was better than RAM cannula with an increase in peak inspiratory pressure. Studies conducted by Iyer and colleagues in the artificial lung model show that RAM leakage rates below 30% lead to adequate pressure transfer to the cannulae, while leakage rates above 50% reduce pressure transfer to the lungs. Similar results have also been found in the work of "Gerdes" et al. A number of studies have been conducted on the clinical use of RAM as a noninvasive ventilation interface and in these studies it has been shown that the use of RAM cannula as an interface in NCPAP, NIPPV or even nasal high frequency ventilation applications to provide NIV is not well tolerated and does not cause gastric perforation or nasal septum damage. In the study of "Nzegwu" et al. It has been shown that in two-thirds of the patients who were treated with RAM cannula and NIV support, the respiratory support was successfully cut off. Nevertheless, none of these studies compared the RAM cannula activity with the other binasal prongs or nasal masks. Investigators compared the effectiveness (rates of surfactant therapy application, rates of intubation, total NIV duration) and nasal injury rates of RAM cannula and short binasal prong as NIV interfaces in preterm infants at neonatal intensive care unit.

Considering the studies made in the artificial lung models of RAM cannulas, which are becoming increasingly widespread in the NICUs, because of their simple and simple design and easy connection to the standard circuits of the ventilators without any intervention, investigators think that the effectiveness of NIV application is insufficient compared to the short binasal cannula.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Respiratory Distress Syndrome, Newborn

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Allocation Method

RANDOMIZED

Intervention Model

PARALLEL

Primary Study Purpose

SUPPORTIVE_CARE

Blinding Strategy

NONE

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

RAM cannula

nasal CPAP support with RAM cannula

Group Type EXPERIMENTAL

nasal CPAP support with RAM cannula

Intervention Type DEVICE

Patients with respiratory distress syndrome who do not need intubation in the delivery room. This groub will be provided with non-invasive respiratory support RAM cannula.

Hudson cannula (short binasal cannula)

nasal CPAP support with Hudson cannula

Group Type ACTIVE_COMPARATOR

nasal CPAP support with Hudson cannula

Intervention Type DEVICE

Patients with respiratory distress syndrome who do not need intubation in the delivery room. This groub will be provided with non-invasive respiratory support Hudson cannula.

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

nasal CPAP support with RAM cannula

Patients with respiratory distress syndrome who do not need intubation in the delivery room. This groub will be provided with non-invasive respiratory support RAM cannula.

Intervention Type DEVICE

nasal CPAP support with Hudson cannula

Patients with respiratory distress syndrome who do not need intubation in the delivery room. This groub will be provided with non-invasive respiratory support Hudson cannula.

Intervention Type DEVICE

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

* gestational age between 26-34 weeks and,
* born in our hospital and,
* Patients with clinical findings (tachypnea, groaning, chest retractions) of RDS

Exclusion Criteria

* Patients who needed intubation to stabilize in the delivery room or who had severe congenital anomalies.
Minimum Eligible Age

1 Minute

Maximum Eligible Age

15 Minutes

Eligible Sex

ALL

Accepts Healthy Volunteers

No

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

Inonu University

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

İsmail Kürşad Gökce

Departman of Pediatrics, Division of Neonatoloji

Responsibility Role PRINCIPAL_INVESTIGATOR

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

Turgut Özal Medical Center

Malatya, , Turkey (Türkiye)

Site Status

Countries

Review the countries where the study has at least one active or historical site.

Turkey (Türkiye)

References

Explore related publications, articles, or registry entries linked to this study.

Davis P, Davies M, Faber B. A randomised controlled trial of two methods of delivering nasal continuous positive airway pressure after extubation to infants weighing less than 1000 g: binasal (Hudson) versus single nasal prongs. Arch Dis Child Fetal Neonatal Ed. 2001 Sep;85(2):F82-5. doi: 10.1136/fn.85.2.f82.

Reference Type BACKGROUND
PMID: 11517198 (View on PubMed)

Gerdes JS, Sivieri EM, Abbasi S. Factors influencing delivered mean airway pressure during nasal CPAP with the RAM cannula. Pediatr Pulmonol. 2016 Jan;51(1):60-9. doi: 10.1002/ppul.23197. Epub 2015 Apr 7.

Reference Type BACKGROUND
PMID: 25851534 (View on PubMed)

Nzegwu NI, Mack T, DellaVentura R, Dunphy L, Koval N, Levit O, Bhandari V. Systematic use of the RAM nasal cannula in the Yale-New Haven Children's Hospital Neonatal Intensive Care Unit: a quality improvement project. J Matern Fetal Neonatal Med. 2015 Apr;28(6):718-21. doi: 10.3109/14767058.2014.929659. Epub 2014 Jun 30.

Reference Type RESULT
PMID: 24874561 (View on PubMed)

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

2017/40

Identifier Type: -

Identifier Source: org_study_id