Non-invasive Ventilation for Extubation Success in Infants Less Than 1,250 Grams
NCT ID: NCT02051491
Last Updated: 2014-05-16
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
UNKNOWN
NA
50 participants
INTERVENTIONAL
2013-06-30
2014-12-31
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
A Trial of Infant Flow Biphasic Nasal Continuous Airway Pressure (NCPAP) Versus Infant Flow NCPAP for the Facilitation of Extubation in Infants </= 1250 Grams
NCT00308789
Pilot Study Comparing Different Modes of Non-invasive Ventilation for the Oral Feeding of Preterm Infants
NCT02055339
Effect of Synchronized vs. Continuous HFNC Using NAVA on WOB in Infants With BPD
NCT04274192
Humidified High Flow Nasal Cannula Versus Nasal Intermittent Positive Ventilation in Neonates
NCT02499744
Study to Improve Treatments and Follow-up of Children Who Need Respiratory Support
NCT02154542
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
There has been a conscious effort amongst neonatologists to reduce the duration of EMV to minimize these undesirable side effects. Non-invasive ventilatory support has been increasingly used to that effect in recent years. Various forms of NIV including NCPAP, BP-NCPAP and nasal intermittent positive pressure ventilation (NIPPV) have become part of the ventilatory management of neonates in NICUs across the globe.
Originally described in the early 1970s,9 the use NCPAP has seen renewed interest since the 1990s when the significance of VILI became apparent. In retrospective studies, NCPAP has been shown to reduce the rates of bronchopulmonary dysplasia (BPD). A recent multi-center prospective randomized controlled trial of infants between 25 and 28 week gestation showed that infants treated with early NCPAP required fewer days of ventilation and had a reduced oxygen dependency after 28 days (although not at 36 weeks corrected GA). A subsequent analysis of these patients showed improved lung mechanics and gas exchange. However NCPAP use is not without its risks. Air leak syndromes, diminished cardiac output, gaseous distention and nasal injury/excoriations are well described complications of its use. Despite these drawbacks, NCPAP remains an efficacious modality to help reduce endotracheal intubation and limit VILI.
Although successful in reducing the reliance on EMV, it is also well known that up to 43-80% of neonates with moderate to severe respiratory disease treated with NCPAP fail and require intubation. BiPhasic NCPAP and NIPPV have been used with increasing frequency in NICUs in recent years to help prevent re-intubation, but with limited evidence guiding their use.
BiPhasic-NCPAP, described in the late 1980s as a form of augmented ventilation, provides two levels of non-invasive pressure support, typically cycled between 20-30 times per minute and the upper level of support usually lasting one second. As in NCPAP, the patient breathes around the two levels of pressures provided. However, there is currently no evidence to suggest that the use of BP-NCPAP offers any advantage over NCPAP. In a recent randomized controlled prospective study from the investigators centre comparing BP-NCPAP (N=69) and NCPAP (N=67), the former was not shown to be superior to the latter in facilitating sustained extubation in infants \< 1,250 grams (67% vs. 58%, P = 0.27). Nevertheless, it is presumed that BP-NCPAP offers the same benefits as NCPAP, and remains in use as a rescue mode of NIV across many NICUs after NCPAP failure.
NIPPV is yet another NIV mode, offering a combination of NCPAP superimposed with ventilator provided peak inspiratory pressure (PIP) via a non-invasive interface, designed to mimic and augment the spontaneous breathing of neonates as in EMV. The PIP provided can be both synchronized or non-synchronized with patient breaths. However there is potential for significant inaccuracies in the synchronization process. Furthermore, the Infant Star ventilator with the Graseby capsule, one of the prototype ventilators capable of providing synchronized NIPPV, is no longer available. Despite this limitation, NIPPV remains in use in both non-synchronized and synchronized forms.8 At this time, to the best of the investigators knowledge, no studies have compared BP-NCPAP and NIPPV directly. In fact, in the recently completed NIPPV trial by Kirpalani et al BP-NCPAP and NIPPV were included in the same arm, which failed to show a reduction in the incidence of BPD compared to the NCPAP arm.
Based on studies conducted so far there is no firm consensus on what is the best non-invasive mode to be used and the modality of choice remains an individual decision depending on the preference and experience of the specific unit. Noninvasive high frequency ventilation is an alternative and relatively new mode of NIV and has been explored in 4 clinical studies so far (appendix A). In a study of 21 preterm and term infants, patients were switched from NCPAP to NIHFV to promote carbon dioxide (CO2) elimination and continued for a mean of 35 (2-144) hours. The authors reported that the partial pressure of carbon dioxide (PaCO2) decreased with the use of this modality from 8.3 to 7.2 kilo pascal (KPa). The major limitations of this study include the heterogeneity of patient population, the etiologies of primary lung disease, small sample size and lack of any control group. In a more recent study by Colaizy et al, NIHFV was used in 14 subjects for a period of 2 hours and a trend towards a decrease in PaCO2 levels was noted with the use of this modality. Limitations of this study include the short duration of NIHFV, small sample size and lack of a control group. The only randomized trial evaluating this modality included 40 term infants with clinically diagnosed transient tachypnea of newborn (TTN) and concluded that the use of NIHFV leads to quicker recovery of TTN compared with the use of CPAP. However the assessment of recovery was subjective, and in a study that was unblinded could be ridden with bias. As well, many of those patients may not have required any form of NIV in the first place. Lastly a study by Czernik et al evaluated a group of 20 neonates at high risk of post-extubation failure who were prophylactically placed on NIHFV. Fourteen of the infants were successfully weaned off to NCPAP, but there was no control group to compare these results with. None of the four trials reported any adverse effects related to the use of NIHFV, although they were not powered to evaluate such outcomes.
At two of the investigators centres (Mount Sinai Hospital and the Hospital for Sick Children) NIHFV has been used as a rescue mode in recent months when NCPAP and/or BP-NCPAP has failed. In a review conducted \[unpublished at this time\] more than half the instances of its use (out of the 21 total cases) were due to increased spells (apneas, bradycardias and/or desaturations). In the six hours preceding and the six hours after initiation of NIHFV, the number of spells reduced from an average of 5.2 (±3.5) to 1.5 (±1.3). The majority of patients tried on NIHFV remained extubated, with less than a third eventually requiring re-intubation. As of yet, no reports of harm were directly linked with the use of NIHFV.
Despite limited evidence, NIHFV holds promise as an alternate mode of NIV. It may be superior to NCPAP/BP-NCPAP with respect to PaCO2 clearance from the lungs and also has the advantage of not requiring breath-synchronization, an issue that has hindered the widespread use of NIPPV. However, definitive assessment of the efficacy of NIHFV requires a prospective, randomized controlled trial. The goal of this study is to compare the rates of intubation when using BP-NCPAP vs. NIHFV as rescue mode of NIV post NCPAP failure in infants \< 1,250 grams.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
RANDOMIZED
PARALLEL
TREATMENT
NONE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
BP-NCPAP
Nasal BP-NCPAP will be delivered using the Infant Flow® SiPAP™ and either nasal prongs or mask interface. A blood gas (arterial if an arterial line exists, or a capillary sample) will be drawn at the time of NCPAP failure (time 0) unless one was done within 1 hour preceding the randomization. The blood gas will then be repeated at 1 hour and recorded along with transcutaneous carbon dioxide (TcCO2) monitor data (if available). Initial settings of BP-NCPAP will be a lower level PEEP of 5 cm water (H2O) and a higher level PEEP of 8 cm H2O at a cycle rate of 20 per minute with 1 second at the higher PEEP per cycle. The settings can then be adjusted and titrated up to a maximum of 7 and 10 cm H2O for the lower and higher PEEPs respectively at a maximum rate of 30 cycles per second based on fraction of inspired oxygen (FiO2) requirements.
BP-NCPAP
Initial settings of BP-NCPAP will be a lower level PEEP of 5 cm H2O and a higher level PEEP of 8 cm H2O at a cycle rate of 20 per minute with 1 second at the higher PEEP per cycle. The settings can then be adjusted and titrated up to a maximum of 7 and 10 cm H2O for the lower and higher PEEPs respectively at a maximum rate of 30 cycles per second based on FiO2 requirements.
NIHFV
NIHFV will be provided using the Drager VN500, using either nasal prong or mask interfaces.A blood gas (arterial if an arterial line exists, or a capillary sample) will be drawn at the time of NCPAP failure (time 0) unless one was done within 1 hour preceding the randomization. The blood gas will then be repeated at 1 hour and recorded along with TcCO2 monitor data (if available). Initial settings for NIHFV arm will be MAP of 8 cm H2O, frequency of 10 Hz, and amplitude of 20 cm H2O. The maximum allowable MAP will be 10 cm of H2O. The range of frequency allowed will be 6 - 14 Hz. Both frequency and amplitude will be adjusted to try and achieve palpable/visible chest movement and to achieve target CO2 levels for the particular patient.
NIHFV
The initial settings will be a MAP of 8 cm H2O, frequency of 10 Hz, and amplitude of 20 cm H2O. The maximum allowable MAP will be 10 cm of H2O. The range of frequency allowed will be 6 - 14 Hz. Both frequency and amplitude will be adjusted to try and achieve palpable/visible chest movement and to achieve target CO2 levels for the particular patient.
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
BP-NCPAP
Initial settings of BP-NCPAP will be a lower level PEEP of 5 cm H2O and a higher level PEEP of 8 cm H2O at a cycle rate of 20 per minute with 1 second at the higher PEEP per cycle. The settings can then be adjusted and titrated up to a maximum of 7 and 10 cm H2O for the lower and higher PEEPs respectively at a maximum rate of 30 cycles per second based on FiO2 requirements.
NIHFV
The initial settings will be a MAP of 8 cm H2O, frequency of 10 Hz, and amplitude of 20 cm H2O. The maximum allowable MAP will be 10 cm of H2O. The range of frequency allowed will be 6 - 14 Hz. Both frequency and amplitude will be adjusted to try and achieve palpable/visible chest movement and to achieve target CO2 levels for the particular patient.
Other Intervention Names
Discover alternative or legacy names that may be used to describe the listed interventions across different sources.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
* Less than 1,250 g when on NCPAP at time of enrollment
Exclusion Criteria
* Severe congenital anomalies including cyanotic congenital heart disease
* Severe nasal excoriation/injury preventing use of NIV interface
* Greater than 2,000 grams at time of randomization
72 Hours
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Mount Sinai Hospital, Canada
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Vibhuti Shah
Staff Neonatologist, Mount Sinai Hospital
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
Vibhuti Shah, MD
Role: PRINCIPAL_INVESTIGATOR
MOUNT SINAI HOSPITAL
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Mount Sinai Hospital
Toronto, Ontario, Canada
Countries
Review the countries where the study has at least one active or historical site.
Central Contacts
Reach out to these primary contacts for questions about participation or study logistics.
Facility Contacts
Find local site contact details for specific facilities participating in the trial.
References
Explore related publications, articles, or registry entries linked to this study.
Mukerji A, Sarmiento K, Lee B, Hassall K, Shah V. Non-invasive high-frequency ventilation versus bi-phasic continuous positive airway pressure (BP-CPAP) following CPAP failure in infants <1250 g: a pilot randomized controlled trial. J Perinatol. 2017 Jan;37(1):49-53. doi: 10.1038/jp.2016.172. Epub 2016 Sep 29.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
12-0276A
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.