Correction by ECCO2-R of Hypercapnia in Patients With DVP in Moderate to Severe ARDS Under Protective Ventilation.
NCT ID: NCT03303807
Last Updated: 2019-07-05
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
COMPLETED
NA
8 participants
INTERVENTIONAL
2018-01-10
2019-03-21
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Strategy of UltraProtective Lung Ventilation With Extracorporeal CO2 Removal for New-Onset Moderate to seVere ARDS
NCT02282657
Post-Market Study of Low-flow ECCO2R Using PrismaLung+
NCT04617093
Ultra-protective Pulmonary Ventilation Supported by Low Flow ECCO2R for Severe ARDS
NCT02252094
Veno-venous Extracorporeal CO2 Removal in ARDS-patients to Treat Respiratory Acidosis
NCT01911533
Enhanced Lung Protective Ventilation With ECCO2R During ARDS
NCT03525691
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
The primary objective of the study is the correction by ECCO2-R of hypercapnia in patients with DVP in moderate to severe ARDS under protective ventilation.
The primary endpoint is the percentage of patients with hypercapnia correction (defined as a 20% decrease in PaCO2 at H2 of ECCO2-R initiation).
The secondary objectives are:
* Demonstrate that ECCO2-R allows in hypercapnic ARDS and DVP patients to correct hypercapnia with H6 and H24, improve DVP and hemodynamics, reduce alveolar dead space, improvement of respiratory mechanics
* Assess the tolerance of the evaluated technique.
The Secondary endpoints are:
\- Relative change of capnia to H6 and H24 in relation to H0; proportion of patients with a decrease of at least 20% of PaCO2 to H6 and H24; changes in echocardiographic indices; hemodynamic parameters; alveolar deadspace and respiratory mechanics to H2, H6 and H24, compared to H0; Complications, Mortality at reanimation discharge (or on D28 if this date occurs before discharge of reanimation).
The intervention is based on the use of ECCO2-R (PrismaLung®, Prismaflex ® Baxter) in eligible patients. ECCO2-R will be initiated as soon as possible after inclusion, for a duration of at least 24 H (possibly prolonged up to 72 H at the decision of reanimator), by jugular or femoral vein-venous.
The size of the catheters, the machine settings, in particular the blood flow and sweep will be standardized according to the state of the art and the recommendations of the manufacturer
The ECO2R venous technique uses devices consisting of a monitor, an exchanger and a pump.
1. The PrismaLung® Kit (Baxter): Single-use EC-marked extracorporeal circuit intended for use for at least 24 hours (maximum 72 hours).
The PrismaLung® kit is intended for use with the Prismaflex® monitor with software version 8.10 or later and its support in conjunction with Prismaflex® single use treatment sets.
2. The Prismaflex HP-X Set (Baxter): blood line set for extracorporeal blood circulation, EC marked or the HF 1400® set (Baxter) (for extra-corporeal CO2 purification combined with purification).
3. The Prismaflex® monitor (Baxter), EC marked, is used routinely in intensive care (continuous extra-renal purification, therapeutic plasma exchange, haemoperfusion, hemopurification).
So that each center has a dedicated monitor for research, this device will be provided by the Baxter laboratory. The monitor will be equipped with a holder for the Prismalung kit marked CE.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
NA
SINGLE_GROUP
PREVENTION
NONE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
Extracorporeal CO2 removal
Extracorporeal CO2 removal (ECCO2-R) (PrismaLung®, Prismaflex ® Baxter)
Extracorporeal CO2 removal (ECCO2-R) (PrismaLung®, Prismaflex ® Baxter)
A low-flow CO2 removal device (Prismalung®, Baxter) will be used with a conventional renal replacement therapy (RRT) platform (Prismaflex®, Baxter). In patients already treated with continuous RRT because of renal failure or metabolic acidosis, the HF 1400® (Baxter) set will be used to combine RRT and decarboxylation. Gas flow through the gas exchanger will be set up to 10 L/min, with an oxygen concentration from 0.21 to 1 and a blood flow of 200-400 mL/min. Patients will be ventilated with a target tidal volume of 6 ml/kg (predicted body weight) and a target plateau pressure below 30 cmH2O.
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
Extracorporeal CO2 removal (ECCO2-R) (PrismaLung®, Prismaflex ® Baxter)
A low-flow CO2 removal device (Prismalung®, Baxter) will be used with a conventional renal replacement therapy (RRT) platform (Prismaflex®, Baxter). In patients already treated with continuous RRT because of renal failure or metabolic acidosis, the HF 1400® (Baxter) set will be used to combine RRT and decarboxylation. Gas flow through the gas exchanger will be set up to 10 L/min, with an oxygen concentration from 0.21 to 1 and a blood flow of 200-400 mL/min. Patients will be ventilated with a target tidal volume of 6 ml/kg (predicted body weight) and a target plateau pressure below 30 cmH2O.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
* Pulmonary vascular dysfunction at echocardiography (pulmonary arterial hypertension, right ventricular dilatation or dyskinesia of the interventricular septum);
* Refractory hypercapnia, defined by a PaCO2 ≥48 mmHg in spite of the reduction of the instrumental dead space and the increase of the respiratory rate.
* Free and informed written consent for persons in a position to consent; consent of the support person/parent/relative in case of incapacity to consent; inclusion in emergency situations (Article L1122-1-2 of the CSP)
Exclusion Criteria
* Known pregnancy or breastfeeding;
* Contra-indication to curative anticoagulation, thrombocytopenia \<50 G / L, heparin-induced thrombocytopenia, known hypersensitivity to heparin or to compounds;
* Femoral or jugular venous access impossible;
* Refractory hypoxemia with indication at ECMO;
* No affiliation to social security or beneficiary
18 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Assistance Publique - Hôpitaux de Paris
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
Armand Mekontso Dessap, MD, PhD
Role: STUDY_CHAIR
Assistance Publique - Hôpitaux de Paris
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Henri Mondor Hospital
Créteil, , France
Countries
Review the countries where the study has at least one active or historical site.
References
Explore related publications, articles, or registry entries linked to this study.
Mekontso Dessap A, Bagate F, Repesse X, Blayau C, Fartoukh M, Canoui-Poitrine F, de Prost N, Vieillard-Baron A. Low-flow ECCO2R conjoined with renal replacement therapy platform to manage pulmonary vascular dysfunction with refractory hypercapnia in ARDS. Heliyon. 2023 Dec 19;10(1):e23878. doi: 10.1016/j.heliyon.2023.e23878. eCollection 2024 Jan 15.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
2016-A01689-42
Identifier Type: OTHER
Identifier Source: secondary_id
P160701
Identifier Type: -
Identifier Source: org_study_id
More Related Trials