Correction by ECCO2-R of Hypercapnia in Patients With DVP in Moderate to Severe ARDS Under Protective Ventilation.

NCT ID: NCT03303807

Last Updated: 2019-07-05

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

COMPLETED

Clinical Phase

NA

Total Enrollment

8 participants

Study Classification

INTERVENTIONAL

Study Start Date

2018-01-10

Study Completion Date

2019-03-21

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

Pulmonary vascular dysfunction (DVP) is associated with a pejorative prognosis during ARDS. There is no specific therapeutic intervention to thwart it. Extracorporeal CO2 purification (ECCO2-R) is a technique that has been very rapidly diffused and adopted in intensive care since commercialization of the devices but, the formal clinical evaluation is insufficient. It could significantly improve the prognosis of patients with both DVP and refractory hypercapnia.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

This is a prospective, non-comparative, open-label, multicenter regional study, without random drawing or blindfolding.

The primary objective of the study is the correction by ECCO2-R of hypercapnia in patients with DVP in moderate to severe ARDS under protective ventilation.

The primary endpoint is the percentage of patients with hypercapnia correction (defined as a 20% decrease in PaCO2 at H2 of ECCO2-R initiation).

The secondary objectives are:

* Demonstrate that ECCO2-R allows in hypercapnic ARDS and DVP patients to correct hypercapnia with H6 and H24, improve DVP and hemodynamics, reduce alveolar dead space, improvement of respiratory mechanics
* Assess the tolerance of the evaluated technique.

The Secondary endpoints are:

\- Relative change of capnia to H6 and H24 in relation to H0; proportion of patients with a decrease of at least 20% of PaCO2 to H6 and H24; changes in echocardiographic indices; hemodynamic parameters; alveolar deadspace and respiratory mechanics to H2, H6 and H24, compared to H0; Complications, Mortality at reanimation discharge (or on D28 if this date occurs before discharge of reanimation).

The intervention is based on the use of ECCO2-R (PrismaLung®, Prismaflex ® Baxter) in eligible patients. ECCO2-R will be initiated as soon as possible after inclusion, for a duration of at least 24 H (possibly prolonged up to 72 H at the decision of reanimator), by jugular or femoral vein-venous.

The size of the catheters, the machine settings, in particular the blood flow and sweep will be standardized according to the state of the art and the recommendations of the manufacturer

The ECO2R venous technique uses devices consisting of a monitor, an exchanger and a pump.

1. The PrismaLung® Kit (Baxter): Single-use EC-marked extracorporeal circuit intended for use for at least 24 hours (maximum 72 hours).

The PrismaLung® kit is intended for use with the Prismaflex® monitor with software version 8.10 or later and its support in conjunction with Prismaflex® single use treatment sets.
2. The Prismaflex HP-X Set (Baxter): blood line set for extracorporeal blood circulation, EC marked or the HF 1400® set (Baxter) (for extra-corporeal CO2 purification combined with purification).
3. The Prismaflex® monitor (Baxter), EC marked, is used routinely in intensive care (continuous extra-renal purification, therapeutic plasma exchange, haemoperfusion, hemopurification).

So that each center has a dedicated monitor for research, this device will be provided by the Baxter laboratory. The monitor will be equipped with a holder for the Prismalung kit marked CE.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Acute Respiratory Distress Syndrome Hypercapnia

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Allocation Method

NA

Intervention Model

SINGLE_GROUP

Primary Study Purpose

PREVENTION

Blinding Strategy

NONE

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

Extracorporeal CO2 removal

Extracorporeal CO2 removal (ECCO2-R) (PrismaLung®, Prismaflex ® Baxter)

Group Type OTHER

Extracorporeal CO2 removal (ECCO2-R) (PrismaLung®, Prismaflex ® Baxter)

Intervention Type DEVICE

A low-flow CO2 removal device (Prismalung®, Baxter) will be used with a conventional renal replacement therapy (RRT) platform (Prismaflex®, Baxter). In patients already treated with continuous RRT because of renal failure or metabolic acidosis, the HF 1400® (Baxter) set will be used to combine RRT and decarboxylation. Gas flow through the gas exchanger will be set up to 10 L/min, with an oxygen concentration from 0.21 to 1 and a blood flow of 200-400 mL/min. Patients will be ventilated with a target tidal volume of 6 ml/kg (predicted body weight) and a target plateau pressure below 30 cmH2O.

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

Extracorporeal CO2 removal (ECCO2-R) (PrismaLung®, Prismaflex ® Baxter)

A low-flow CO2 removal device (Prismalung®, Baxter) will be used with a conventional renal replacement therapy (RRT) platform (Prismaflex®, Baxter). In patients already treated with continuous RRT because of renal failure or metabolic acidosis, the HF 1400® (Baxter) set will be used to combine RRT and decarboxylation. Gas flow through the gas exchanger will be set up to 10 L/min, with an oxygen concentration from 0.21 to 1 and a blood flow of 200-400 mL/min. Patients will be ventilated with a target tidal volume of 6 ml/kg (predicted body weight) and a target plateau pressure below 30 cmH2O.

Intervention Type DEVICE

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

* Moderate to severe ARDS according to the Berlin definition;
* Pulmonary vascular dysfunction at echocardiography (pulmonary arterial hypertension, right ventricular dilatation or dyskinesia of the interventricular septum);
* Refractory hypercapnia, defined by a PaCO2 ≥48 mmHg in spite of the reduction of the instrumental dead space and the increase of the respiratory rate.
* Free and informed written consent for persons in a position to consent; consent of the support person/parent/relative in case of incapacity to consent; inclusion in emergency situations (Article L1122-1-2 of the CSP)

Exclusion Criteria

* Age \<18 years;
* Known pregnancy or breastfeeding;
* Contra-indication to curative anticoagulation, thrombocytopenia \<50 G / L, heparin-induced thrombocytopenia, known hypersensitivity to heparin or to compounds;
* Femoral or jugular venous access impossible;
* Refractory hypoxemia with indication at ECMO;
* No affiliation to social security or beneficiary
Minimum Eligible Age

18 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

No

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

Assistance Publique - Hôpitaux de Paris

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Responsibility Role SPONSOR

Principal Investigators

Learn about the lead researchers overseeing the trial and their institutional affiliations.

Armand Mekontso Dessap, MD, PhD

Role: STUDY_CHAIR

Assistance Publique - Hôpitaux de Paris

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

Henri Mondor Hospital

Créteil, , France

Site Status

Countries

Review the countries where the study has at least one active or historical site.

France

References

Explore related publications, articles, or registry entries linked to this study.

Mekontso Dessap A, Bagate F, Repesse X, Blayau C, Fartoukh M, Canoui-Poitrine F, de Prost N, Vieillard-Baron A. Low-flow ECCO2R conjoined with renal replacement therapy platform to manage pulmonary vascular dysfunction with refractory hypercapnia in ARDS. Heliyon. 2023 Dec 19;10(1):e23878. doi: 10.1016/j.heliyon.2023.e23878. eCollection 2024 Jan 15.

Reference Type DERIVED
PMID: 38226285 (View on PubMed)

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

2016-A01689-42

Identifier Type: OTHER

Identifier Source: secondary_id

P160701

Identifier Type: -

Identifier Source: org_study_id

More Related Trials