Visceral Manifold Study for the Repair of Thoracoabdominal Aortic Aneurysms
NCT ID: NCT03113383
Last Updated: 2022-11-08
Study Results
Outcome measurements, participant flow, baseline characteristics, and adverse events have been published for this study.
View full resultsBasic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
TERMINATED
NA
4 participants
INTERVENTIONAL
2017-08-18
2021-10-06
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Repair of Thoracoabdominal Aortic Aneurysms
NCT03111459
Endovascular Repair of Thoracoabdominal Aortic Aneurysms
NCT04009512
Visceral Manifold Study for the Repair of TAAA
NCT03075748
Visceral Manifold and Unitary Device Study for the Repair of Thoracoabdominal Aortic Aneurysms
NCT02294435
Endovascular Repair of Abdominal Aortic Aneurysms
NCT00803075
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
The primary effectiveness endpoint is the proportion of the study subjects with treatment success at 1 year. The data will be presented as quality outcomes with the number of study subjects with treatment success compared to the overall patient population.
Additionally, data outcomes from this study will be entered into a common vascular database so that data can be pooled with other PS-IDEs. This would provide consistent reporting across the PS-IDEs. Additionally, the PS-IDEs will be evaluating the same device and endpoints to allow for a pool-ability of data across the sites.
The pooled data will be separated into two separate study arms: primary study arm and expanded selection arm.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
NON_RANDOMIZED
SINGLE_GROUP
TREATMENT
NONE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
Primary Arm
Use of the thoracic bifurcation and the visceral manifold to repair thoracoabdominal aortic aneurysms in patients having appropriate anatomy.
Thoracoabdominal Aortic Aneurysm Repair
Thoracoabdominal aortic aneurysm repair
Expanded Selection Arm
Use of the thoracic bifurcation and the visceral manifold to repair thoracoabdominal aortic aneurysms in patients having appropriate anatomy.
Thoracoabdominal Aortic Aneurysm Repair
Thoracoabdominal aortic aneurysm repair
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
Thoracoabdominal Aortic Aneurysm Repair
Thoracoabdominal aortic aneurysm repair
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
* An aneurysm with a maximum diameter of greater than or equal to 5.5 cm or 2 times the normal diameter just proximal to the aneurysm using orthogonal (i.e., perpendicular to the centerline) measurements
* Aneurysm with a history of growth greater than or equal to 0.5 cm in 6 months
* Saccular aneurysm deemed at significant risk for rupture
* Symptomatic aneurysm greater than 4.5 cm
* Axillary or brachial and iliac or femoral access vessel morphology that is compatible with vascular access techniques, devices or accessories, with or without use of a surgical conduit
* Proximal landing zone for the thoracic bifurcation stent graft that has:
* Greater than or equal to 2.5 cm of nonaneurysmal aortic segment including previously placed graft material (neck) distal to the left subclavian artery (LSA) diameter in the range of 26-42 mm
* Adequate distance from the celiac artery, in order to accommodate cannulation from the antegrade access point when considering the total deployed length of the thoracic bifurcation and visceral manifold
* Minimum branch vessel diameter greater than 5 mm
* Iliac artery or aortic distal fixation site, including both native tissue and previously placed graft, greater than or equal to 15 mm in length and diameter in the range of 8 - 25 mm
* Age: greater than or equal to 18 years old
* Life expectancy: greater than 1 year
* Patient that meets the criteria for inclusion in the primary study arm but has one or more of the following criteria which would exclude them from the primary study arm:
* Minimum branch vessel diameters \<less than 5mm
* Urgent or emergent presentation
* Patient has a contained rupture
* Patient has a ruptured aneurysm
* Patient has a type B dissection (subacute or chronic) in the portion of the aorta intended to be treated
* Poor performance status including two major system failures (including but not limited to cardiovascular, pulmonary, renal, hepatobiliary, and neuromuscular)
* Baseline creatinine greater than greater than or equal to 2.0 mg/dL
* Anatomy that does not allow for maintenance of at least one hypogastric artery
* Anatomy that does not allow primary or assisted patency of the left subclavian artery
* Prior aneurysm repair that would involve relining of the previously placed graft material requiring placement of the investigational system in a landing zone that expands beyond any limits of the previously placed graft material
* Obstructive stenting of any or all of the visceral vessels
Or
* A patient that meets the criteria for inclusion into the primary study arm and:
* Would not be eligible for the primary study arm per a documented reason other than those outlined above, and
* Per the opinion of the Principal Investigator, with concurrence of the IRB, alternatives therapies are unsatisfactory and the probable risk of using the investigational device is no greater than the probable risk from the disease or condition.
These will be determined by standard of care assessments of their disease/aneurysm morphology by the treating investigator.
Exclusion Criteria
* Can be treated in accordance with the instructions for use with a legally marketed endovascular device
* Is eligible for enrollment in a manufacturer-sponsored IDE at the investigational site
* Unwilling to comply with the follow-up schedule
* Inability or refusal to give informed consent
* Urgent or emergent presentation
* Patient is pregnant or breastfeeding
* Patient has a contained rupture
* Patient has a ruptured aneurysm
* Patient has a dissection in the portion of the aorta intended to be treated
* Obstructive stenting of any or all of the visceral vessels
* Poor performance status including two major system failures (including but not limited to cardiovascular, pulmonary, renal, hepatobiliary, and neuromuscular)
* Known sensitivities or allergies to the materials of construction of the devices, including nitinol (Nickel: Titanium) polyester, platinum-iridium, polytetrafluoroethylene (PTFE), platinum, gold, polyethylene, or stainless steel.
* Known hypersensitivity or contraindication to anticoagulation or contrast media that cannot be adequately medically managed
* Uncorrectable coagulopathy
* Body habitus that would inhibit x-ray visualization of the aorta or exceeds the safe capacity of the equipment
* Patient has had a major surgical or interventional procedure unrelated to the treatment of the aneurysm planned less than 30 days of the endovascular repair
* Unstable angina (defined as angina with a progressive increase in symptoms, new onset at rest or nocturnal angina)
* Systemic or local infection that may increase the risk of endovascular graft infection
* Baseline creatinine greater than or equal to 2.0 mg/dL
* History of connective tissue disorders (e.g., Marfan Syndrome in the primary arm only, not applicable for patients in the the expanded access arm, Ehler's Danlos Syndrome)
* Prior aneurysm repair that would involve relining of the previously placed graft material requiring placement of the investigational system in a landing zone that expands beyond any limits of the previously placed graft material
* Minimum branch vessel diameter less than 5 mm
* Thrombus or excessive calcification in the proximal aortic neck
* Anatomy that would not allow maintenance of at least one patent hypogastric artery
* Anatomy that would not allow primary or assisted patency of the left subclavian artery
18 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Medtronic
INDUSTRY
Vanderbilt University Medical Center
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Thomas Naslund
Professor Vascular Surgery
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
Thomas C Naslund, MD
Role: PRINCIPAL_INVESTIGATOR
Chief, Division of Vascular Surgery
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Vanderbilt University Medical Center
Nashville, Tennessee, United States
Countries
Review the countries where the study has at least one active or historical site.
Provided Documents
Download supplemental materials such as informed consent forms, study protocols, or participant manuals.
Document Type: Study Protocol and Statistical Analysis Plan
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
161627
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.