Visceral Manifold and Unitary Device Study for the Repair of Thoracoabdominal Aortic Aneurysms
NCT ID: NCT02294435
Last Updated: 2024-12-16
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
ACTIVE_NOT_RECRUITING
NA
250 participants
INTERVENTIONAL
2015-02-28
2029-12-31
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Keywords
Explore important study keywords that can help with search, categorization, and topic discovery.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
NON_RANDOMIZED
SINGLE_GROUP
TREATMENT
NONE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
Primary Study Arm
The TAAA Debranching Stent Graft System is comprised of two investigational devices including the Thoracic Bifurcation and the Visceral Manifold and the Unitary Manifold. The thoracic bifurcation and the visceral manifold as well as the unitary manifold work to facilitate endovascular stenting of the visceral vessels (renals, celiac, SMA) while maintaining flow to the visceral and infrarenal segments.
Visceral Manifold and Thoracic Bifurcation
Visceral Manifold and Thoracic Bifurcation Endovascular stent graft system
Unitary Manifold
Unitary Manifold Endovascular stent graft system
Expanded Selection Arm
The expanded selection arm is for subjects not eligible for open repair or other endovascular options due to comorbidities or anatomical limitations and do not meet inclusion in the primary study arm. The Thoracic Bifurcation and the Visceral Manifold as well as the Unitary Manifold work to facilitate endovascular stenting of the visceral vessels (renals, celiac, SMA) while maintaining flow to the visceral and infrarenal segments.
Visceral Manifold and Thoracic Bifurcation
Visceral Manifold and Thoracic Bifurcation Endovascular stent graft system
Unitary Manifold
Unitary Manifold Endovascular stent graft system
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
Visceral Manifold and Thoracic Bifurcation
Visceral Manifold and Thoracic Bifurcation Endovascular stent graft system
Unitary Manifold
Unitary Manifold Endovascular stent graft system
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
* Aneurysm with a history of growth ≥ 0.5 cm in 6 months
* Saccular aneurysm deemed at significant risk for rupture
* Symptomatic aneurysm greater than or equal to 4.5 cm
* Axillary or brachial and iliac or femoral access vessel morphology that is compatible with vascular access techniques, devices or accessories, with or without use of a surgical conduit
* Proximal landing zone for the thoracic bifurcation stent graft:
•≥ 2.5 cm of nonaneurysmal aortic segment including previously placed graft material (neck) distal to the left subclavian artery (LSA)
* Diameter in the range of 26-42 mm
* Adequate distance from the celiac artery, in order to accommodate cannulation from the antegrade access point when considering the total deployed length of the thoracic bifurcation and visceral manifold
* Proximal landing zone for the unitary manifold stent graft:
* Nonaneurysmal aortic segment including previously placed graft material (neck) with a minimum seal zone length of 3 cm
* Diameter in the range of 19-32 mm
* Iliac artery or aortic distal fixation site greater than or equal to 15 mm in length and diameter in the range of 8 - 25 mm
* Age: ≥ 18 years old
* Life expectancy: \> 1 year
Patient that meets the criteria for inclusion in the primary study arm but has one or more of the following criteria which would exclude them from the primary study arm:
* Minimum branch vessel diameter less than 5 mm
* Urgent or emergent presentation
* Patient has a contained rupture
* Patient has a ruptured aneurysm
* Patient has a type B dissection (subacute or chronic) in the portion of the aorta intended to be treated
* Poor performance status including two major system failures (cardiovascular, pulmonary, renal, hepatobiliary, and neuromuscular)
* Baseline creatinine greater than or equal to 2.0 mg/dL
* Anatomy that would not allow for maintenance of at least one hypogastric artery
* Anatomy that would not allow for primary or assisted patency of the left subclavian artery
* Prior aneurysm repair that would involve relining of the previously placed graft material requiring placement of the investigational system in the a landing zone that expands beyond any limits of the previously placed graft material
* Obstructive stenting of any or all of the visceral vessels
OR
Patient that meets criteria for inclusion in the primary study arm and:
* Would not be eligible for the primary study arm per a documented reason other than those outlined above, and
* Per the opinion of the Principal Investigator, with concurrence of the IRB, alternative therapies are unsatisfactory and the probable risk of using the investigational device is no greater than the probable risk from the disease or condition.
Exclusion Criteria
* Patient is a good candidate for and elects for open surgical repair
* Can be treated in accordance with the instructions for use with a legally marketed
* Is eligible for enrollment in a manufacturer-sponsored IDE at the investigational site
* Unwilling to comply with the follow-up schedule
* Inability or refusal to give informed consent
* Urgent or emergent presentation
* Patient is pregnant or breastfeeding
* Patient has a contained rupture
* Patient has a ruptured aneurysm
* Patient has a dissection in the portion of the aorta intended to be treated
* Obstructive stenting of any or all of the visceral vessels
* Poor performance status including two major system failures (cardiovascular, pulmonary, renal, hepatobiliary, and neuromuscular)
* Known sensitivities or allergies to the materials of construction of the devices, including nitinol (Nickel:Titanium), polyester, platinum-iridium, polytetrafluoroethylene (PTFE)
* Known hypersensitivity or contraindication to anticoagulation or contrast media that cannot be adequately medically managed
* Uncorrectable coagulopathy
* Body habitus that would inhibit x-ray visualization of the aorta or exceeds the safe capacity of the equipment
* Patient has had a major surgical or interventional procedure unrelated to the treatment of the aneurysm planned \< 30 days of the endovascular repair
* Unstable angina (defined as angina with a progressive increase in symptoms, new onset at rest or nocturnal angina)
* Systemic or local infection that may increase the risk of endovascular graft infection
* Baseline creatinine greater than 2.0 mg/dL
* History of connective tissue disorders (e.g., Marfan Syndrome, Ehler's Danlos Syndrome)
* Prior aneurysm repair that would involve relining of the previously placed graft material requiring placement of the investigational system in a landing zone that expands beyond any limits of the previously placed graft material
* Minimum branch vessel diameter less than 5 mm
* Thrombus or excessive calcification within the neck of the aneurysm
* Anatomy that would not allow maintenance of at least one patent hypogastric artery
* Anatomy that would not allow primary or assisted patency of the left subclavian artery
18 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Dakota Vascular
OTHER
Sanford Health
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Patrick Kelly
Vascular Surgeon
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
Patrick Kelly, MD
Role: PRINCIPAL_INVESTIGATOR
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Sioux Falls, South Dakota, United States
Countries
Review the countries where the study has at least one active or historical site.
References
Explore related publications, articles, or registry entries linked to this study.
Anderson J, Nykamp M, Danielson L, Remund T, Kelly PW. A novel endovascular debranching technique using physician-assembled endografts for repair of thoracoabdominal aneurysms. J Vasc Surg. 2014 Nov;60(5):1177-1184. doi: 10.1016/j.jvs.2014.05.090. Epub 2014 Jul 3.
Jorgensen BD, Malek M, VandenHull A, Remund T, Truong KC, Pohlson K, Kelly PW. A novel physician-assembled endograft for the repair of pararenal, paravisceral, Crawford type IV thoracoabdominal aortic aneurysms, and aneurysms requiring treatment after prior repair. J Vasc Surg. 2020 Dec;72(6):1897-1905.e2. doi: 10.1016/j.jvs.2020.03.045. Epub 2020 Apr 23.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
SH VMS
Identifier Type: -
Identifier Source: org_study_id