Endovascular Repair of Thoracoabdominal Aortic Aneurysms

NCT ID: NCT04009512

Last Updated: 2021-12-14

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

ACTIVE_NOT_RECRUITING

Clinical Phase

NA

Total Enrollment

15 participants

Study Classification

INTERVENTIONAL

Study Start Date

2020-10-06

Study Completion Date

2026-08-26

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

The primary objective of this study is to assess the use of the thoracic bifurcation and the visceral manifold devices in the repair thoracoabdominal aortic aneurysms in patients with appropriate anatomy. The primary intent of the study is to assess safety and preliminary effectiveness of the device. Additionally, the study will assess technical success and treatment success at each follow-up interval.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

The primary objective is to assess the use of the thoracic bifurcation and the visceral manifold stent graft system to repair thoracoabdominal aortic aneurysms in patients with appropriate anatomy. The primary intent of the study is to assess safety (i.e. freedom from major adverse events (MAE) at 30 days) and preliminary effectiveness (i.e., treatment success and technical success) of the device (i.e., the proportion of treatment group subjects that achieve and maintain treatment success at one year). Additionally, the study will assess technical success and treatment success at each follow-up interval.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Thoracoabdominal Aortic Aneurysm

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Allocation Method

NON_RANDOMIZED

Intervention Model

PARALLEL

Primary Study Purpose

TREATMENT

Blinding Strategy

NONE

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

Primary Study Arm

The Valiant Thoracoabdominal Stent Graft System is comprised of two investigational devices including the Thoracic Bifurcate and the Visceral Manifold. These devices work to facilitate endovascular stenting of the visceral vessels (renals, celiac, SMA) while maintaining flow to the visceral and infrarenal segments.

Group Type EXPERIMENTAL

Valiant Thoracoabdominal Stent Graft System

Intervention Type DEVICE

This system of devices works to facilitate endovascular stenting of the visceral vessels (renals, celiac, SMA) while maintaining flow to the visceral and infrarenal segments in patients with thoracoabdominal aneurysms.

Expanded Use Arm

The Valiant Thoracoabdominal Stent Graft System is comprised of two investigational devices including the Thoracic Bifurcate and the Visceral Manifold. These devices work to facilitate endovascular stenting of the visceral vessels (renals, celiac, SMA) while maintaining flow to the visceral and infrarenal segments. The expanded use arm provides broaden inclusion criteria to include select patients excluded from the primary study arm.

Group Type EXPERIMENTAL

Valiant Thoracoabdominal Stent Graft System

Intervention Type DEVICE

This system of devices works to facilitate endovascular stenting of the visceral vessels (renals, celiac, SMA) while maintaining flow to the visceral and infrarenal segments in patients with thoracoabdominal aneurysms.

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

Valiant Thoracoabdominal Stent Graft System

This system of devices works to facilitate endovascular stenting of the visceral vessels (renals, celiac, SMA) while maintaining flow to the visceral and infrarenal segments in patients with thoracoabdominal aneurysms.

Intervention Type DEVICE

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

A patient may be entered into the study if the patient has at least one of the following:

* An aneurysm with a maximum diameter of \> 5.5 cm or 2 times the normal diameter just proximal to the aneurysm using orthogonal (i.e., perpendicular to the centerline) measurements
* Aneurysm with a history of growth \> 0.5 cm in 6 months
* Saccular aneurysm deemed at significant risk for rupture
* Symptomatic aneurysm greater than or equal to 4.5 cm


* Axillary or brachial and iliac or femoral access vessel morphology that is compatible with vascular access techniques, devices or accessories, with or without use of a surgical conduit
* Proximal landing zone for the thoracic bifurcation stent graft that has:

* ≥ 2.5 cm of nonaneurysmal aortic segment including previously placed graft material (neck) distal to the left subclavian artery (LSA) and a diameter in the range of 26-42 mm
* Adequate distance from the celiac artery, in order to accommodate cannulation from the antegrade access point when considering the total deployed length of the thoracic bifurcation and visceral manifold
* Iliac artery or aortic distal fixation site, including both native tissue and previously placed graft, greater than or equal to 15 mm in length and diameter in the range of 8 - 25 mm
* Age: ≥ 18 years old
* Life expectancy: \> 1 year


Patient that meet the criteria for inclusion in the primary study arm but has one or more of the following criteria which would exclude them from the primary study arm:


* Minimum branch vessel diameter \<5mm
* Urgent or emergent presentation
* Patient has a contained rupture
* Patient has a ruptured aneurysm
* Patient has a type B dissection (subacute or chronic) in the portion of the aorta intended to be treated
* Poor performance status including two major system failures (including but not limited to cardiovascular, pulmonary, renal, hepatobiliary, and neuromuscular)
* Baseline creatinine greater than or equal to 2.0 mg/dL
* Anatomy that does not allow maintenance of at least one hypogastric artery
* Anatomy that does not allow primary or assisted patency of the left subclavian artery
* Prior aneurysm repair that would involve relining of the previously placed graft material requiring placement of the investigational system in a landing zone that expands beyond any limits of the previously placed graft material
* Obstructive stenting of any or all of the visceral vessels
* Patient that meets the criteria for inclusion in the primary study arm and:

* Would not be eligible for the primary study arm per a documented reason other than those outlined above, and
* Per the opinion of the Principal Investigator, with concurrence of the IRB, alternative therapies are unsatisfactory and the probable risk of using the investigational device is no greater than the probable risk from the disease or condition.

Exclusion Criteria

* Patient is a good candidate for and elects for open surgical repair
* Can be treated in accordance with the instructions for use with a legally marketed endovascular prosthesis
* Is eligible for enrollment in a manufacturer-sponsored IDE at the investigational site
* Unwilling to comply with the follow-up schedule
* Inability or refusal to give informed consent by patient or legal representative
* Urgent or emergent presentation
* Patient is pregnant or breastfeeding
* Patient has a contained rupture
* Patient has a ruptured aneurysm
* Patient has a dissection in the portion of the aorta intended to be treated
* Obstructive stenting of any or all of the visceral vessels
* Poor performance status including two major system failures (including but not limited to cardiovascular, pulmonary, renal, hepatobiliary, and neuromuscular)


* Known sensitivities or allergies to the materials of construction of the devices, including nitinol (Nickel: Titanium), polyester, platinum-iridium, polytetrafluoroethylene (PTFE), platinum, gold, polyethylene, or stainless steel.
* Known hypersensitivity or contraindication to anticoagulation or contrast media that cannot be adequately medically managed
* Uncorrectable coagulopathy
* Body habitus that would inhibit x-ray visualization of the aorta or exceeds the safe capacity of the equipment
* Patient has had a major surgical or interventional procedure unrelated to the treatment of the aneurysm planned \< 30 days of the endovascular repair
* Unstable angina (defined as angina with a progressive increase in symptoms, new onset at rest or nocturnal angina)
* Systemic or local infection that may increase the risk of endovascular graft infection
* Baseline creatinine greater than or equal to 2.0 mg/dL
* History of connective tissue disorders (e.g., Marfan Syndrome, Ehler's Danlos Syndrome)
* Prior aneurysm repair that would involve relining of the previously placed graft material requiring placement of the investigational system in a landing zone that expands beyond any limits of the previously placed graft material


* Minimum branch vessel diameter less than 5 mm
* Thrombus or excessive calcification within the proximal aortic neck
* Anatomy that would not allow maintenance of at least one patent hypogastric artery
* Anatomy that would not allow primary or assisted patency of the left subclavian artery
Minimum Eligible Age

18 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

No

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

Medtronic

INDUSTRY

Sponsor Role collaborator

NAMSA

OTHER

Sponsor Role collaborator

Sanford Health

OTHER

Sponsor Role collaborator

Matthew Eagleton

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Matthew Eagleton

Chief, Division of Vascular and Endovascular Surgery

Responsibility Role SPONSOR_INVESTIGATOR

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

Massachusetts General Hospital

Boston, Massachusetts, United States

Site Status

Countries

Review the countries where the study has at least one active or historical site.

United States

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

IP-01-001

Identifier Type: -

Identifier Source: org_study_id