Visceral Manifold Study for the Repair of TAAA

NCT ID: NCT03075748

Last Updated: 2025-01-22

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

ACTIVE_NOT_RECRUITING

Clinical Phase

NA

Total Enrollment

15 participants

Study Classification

INTERVENTIONAL

Study Start Date

2017-12-19

Study Completion Date

2027-02-01

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

The outcomes from prior clinical evaluation of the study device, including successfully treating 99% (84/85) of the intended target vessels and 96% (27/28) limb patency observed at one year, demonstrate the potential benefits of the device. When contrasted with open repair's significant complication rates and branch fenestrated device's significant anatomic and logistic limitations, the potential risk of the proposed novel graft does not outweigh the potential benefit of widened anatomic availability and improved patency rates. Given the potential benefits, the investigators feel that it is justified to expose the target patient population to the potential risk. The non-clinical testing performed by Medtronic and the clinical results reported by Sanford Health show adequate safety of the device to support an early feasibility study.

The investigators would like to perform an early feasibility study under a defined and controlled protocol to collect prospective preliminary safety and device functionality data. The investigators believe an early feasibility study is most appropriate for this novel approach. The limited sample size allows adequate patient data to be collected under a controlled protocol without exposing a large patient population to the risk associated with a novel device design.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

This study is a prospective, single-center, non-randomized, single-arm study to evaluate the therapeutic benefit of the TAAA Debranching Stent Graft System. A total of 15 patients will be enrolled in the study.

* 10 subjects total will be treated in the primary study arm
* 5 subjects total will be treated in the expanded selection arm

The duration of the Investigation is anticipated as follows:

* Time to Complete Enrollment: 24 months
* Subject Follow-up Time: 5 years from last subject enrollment
* Total Duration Time: 7 years

The primary objective of the clinical investigation "Visceral Manifold Study for the repair of thoracoabdominal aortic aneurysms" is to assess the use of the TAAA Debranching Stent Graft System to repair thoracoabdominal aortic aneurysms in patients having appropriate anatomy. The primary intent of the study is to assess safety acutely (i.e. freedom from major adverse events (MAE) at 30 days) and preliminary effectiveness (i.e., treatment success and technical success) of the device acutely (i.e., the proportion of treatment group subjects that achieve and maintain treatment success at one year).

Additionally, the study will assess technical success and treatment success at each follow-up interval.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Thoracoabdominal Aortic Aneurysms

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Allocation Method

NON_RANDOMIZED

Intervention Model

PARALLEL

Primary Study Purpose

TREATMENT

Blinding Strategy

NONE

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

Primary study

Patients meeting primary inclusion/exclusion criteria will be enrolled in primary study arm and be treated with the TAAA Debranching Stent Graft System.

Group Type EXPERIMENTAL

TAAA Debranching Stent Graft System

Intervention Type DEVICE

The TAAA Debranching Stent Graft System is made up of two main body components and makes use of several off-the-shelf FDA-approved stent graft components. The two custom main body grafts are the thoracic bifurcation and the visceral manifold. The thoracic bifurcation is deployed in the thoracic aorta and provides the proximal seal for the device. The two limbs of the thoracic bifurcation allows for continued aortic flow while deploying the visceral segment. The visceral manifold is deployed within the larger 20 mm limb of the thoracic bifurcation to set the stage for the visceral debranching. The branches of the visceral manifold extend to the visceral vessel with the use of covered bridging stents and provide distal seal of the manifold.

Expanded selection

Patients who fail to meet inclusion criteria for the primary study arm may be enrolled under the expanded selection arm and be treated with the TAAA Debranching Stent Graft System.

Group Type EXPERIMENTAL

TAAA Debranching Stent Graft System

Intervention Type DEVICE

The TAAA Debranching Stent Graft System is made up of two main body components and makes use of several off-the-shelf FDA-approved stent graft components. The two custom main body grafts are the thoracic bifurcation and the visceral manifold. The thoracic bifurcation is deployed in the thoracic aorta and provides the proximal seal for the device. The two limbs of the thoracic bifurcation allows for continued aortic flow while deploying the visceral segment. The visceral manifold is deployed within the larger 20 mm limb of the thoracic bifurcation to set the stage for the visceral debranching. The branches of the visceral manifold extend to the visceral vessel with the use of covered bridging stents and provide distal seal of the manifold.

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

TAAA Debranching Stent Graft System

The TAAA Debranching Stent Graft System is made up of two main body components and makes use of several off-the-shelf FDA-approved stent graft components. The two custom main body grafts are the thoracic bifurcation and the visceral manifold. The thoracic bifurcation is deployed in the thoracic aorta and provides the proximal seal for the device. The two limbs of the thoracic bifurcation allows for continued aortic flow while deploying the visceral segment. The visceral manifold is deployed within the larger 20 mm limb of the thoracic bifurcation to set the stage for the visceral debranching. The branches of the visceral manifold extend to the visceral vessel with the use of covered bridging stents and provide distal seal of the manifold.

Intervention Type DEVICE

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

* A patient may be entered into the study if the patient has at least one of the following:

* An aneurysm with a maximum diameter of \> 5.5 cm or 2 times the normal diameter just proximal to the aneurysm using orthogonal (i.e., perpendicular to the centerline) measurements
* Aneurysm with a history of growth \> 0.5 cm in 6 months
* Saccular aneurysm deemed at significant risk for rupture
* Symptomatic aneurysm greater than 4.5 cm
* Axillary or brachial and iliac or femoral access vessel morphology that is compatible with vascular access techniques, devices or accessories, with or without use of a surgical conduit
* Proximal landing zone for the thoracic bifurcation stent graft that has:

* ≥ 2.5 cm of nonaneurysmal aortic segment including previously placed graft material (neck) distal to the left subclavian artery (LSA) diameter in the range of 26-42 mm
* Adequate distance from the celiac artery, in order to accommodate cannulation from the antegrade access point when considering the total deployed length of the thoracic bifurcation and visceral manifold
* Minimum branch vessel diameter greater than 5 mm
* Iliac artery or aortic distal fixation site, including both native tissue and previously placed graft, greater than or equal to 15 mm in length and diameter in the range of 8 - 25 mm
* Age: ≥ 18 years old
* Life expectancy: \> 1 year



* Patient that meets the criteria for inclusion in the primary study arm but has one or more of the following criteria which would exclude them from the primary study arm:

* Minimum branch vessel diameter less than 5 mm
* Urgent or emergent presentation
* Patient has a contained rupture
* Patient has a ruptured aneurysm
* Patient has a type B dissection (subacute or chronic) in the portion of the aorta intended to be treated
* Poor performance status including two major system failures (cardiovascular, pulmonary, renal, hepatobiliary, and neuromuscular)
* Baseline creatinine greater than 2.0 mg/dL
* Anatomy that would not allow for maintenance of at least one hypogastric artery
* Anatomy that would not allow for primary or assisted patency of the left subclavian artery Or
* Patient that meets the criteria for inclusion in the primary study arm and:

* Would not be eligible for the primary study arm per a documented reason other than those outlined above, and
* Per the opinion of the Principal Investigator, with concurrence of the IRB, alternative therapies are unsatisfactory and the probable risk of using the investigational device is no greater than the probable risk from the disease or condition.

Exclusion Criteria

General exclusion

* Patient is a good candidate for and elects for open surgical repair
* Can be treated in accordance with the instructions for use with a legally marketed endovascular prosthesis
* Is eligible for enrollment in a manufacturer-sponsored IDE at the investigational site
* Unwilling to comply with the follow-up schedule
* Inability or refusal to give informed consent
* Urgent or emergent presentation
* Patient is pregnant or breastfeeding
* Patient has a contained rupture
* Patient has a ruptured aneurysm
* Patient has a dissection in the portion of the aorta intended to be treated
* Obstructive stenting of any or all of the visceral vessels
* Poor performance status including two major system failures (cardiovascular, pulmonary, renal, hepatobiliary, and neuromuscular)


* Known sensitivities or allergies to the materials of construction of the devices, including nitinol (Nickel: Titanium), polyester, platinum-iridium, polytetrafluoroethylene (PTFE), platinum, gold, polyethylene, or stainless steel.
* Known hypersensitivity or contraindication to anticoagulation or contrast media that cannot be adequately medically managed
* Uncorrectable coagulopathy
* Body habitus that would inhibit x-ray visualization of the aorta or exceeds the safe capacity of the equipment
* Patient has had a major surgical or interventional procedure unrelated to the treatment of the aneurysm planned \< 30 days of the endovascular repair
* Unstable angina (defined as angina with a progressive increase in symptoms, new onset at rest or nocturnal angina)
* Systemic or local infection that may increase the risk of endovascular graft infection
* Baseline creatinine greater than 2.0 mg/dL
* History of connective tissue disorders (e.g., Marfan Syndrome, Ehler's Danlos Syndrome)


* Thrombus or excessive calcification within the neck of the aneurysm
* Anatomy that would not allow maintenance of at least one patent hypogastric artery
* Anatomy that would not allow primary or assisted patency of the left subclavian artery
Minimum Eligible Age

18 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

No

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

Medtronic

INDUSTRY

Sponsor Role collaborator

Sanford Health

OTHER

Sponsor Role collaborator

University of South Florida

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Responsibility Role SPONSOR

Principal Investigators

Learn about the lead researchers overseeing the trial and their institutional affiliations.

Murray Shames, MD

Role: PRINCIPAL_INVESTIGATOR

University of South Florida

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

Tampa General Hospital/ University of South Florida

Tampa, Florida, United States

Site Status

University of South Florida - South Tampa Campus

Tampa, Florida, United States

Site Status

Countries

Review the countries where the study has at least one active or historical site.

United States

References

Explore related publications, articles, or registry entries linked to this study.

Anderson J, Nykamp M, Danielson L, Remund T, Kelly PW. A novel endovascular debranching technique using physician-assembled endografts for repair of thoracoabdominal aneurysms. J Vasc Surg. 2014 Nov;60(5):1177-1184. doi: 10.1016/j.jvs.2014.05.090. Epub 2014 Jul 3.

Reference Type RESULT
PMID: 24997805 (View on PubMed)

Anderson J, Nykamp M, Remund T, Kelly P. Complete endovascular debranching of the aortic arch: A report of two cases. Vascular. 2015 Jun;23(3):310-5. doi: 10.1177/1708538114542174. Epub 2014 Jul 11.

Reference Type RESULT
PMID: 25015113 (View on PubMed)

Danielson L, Anderson J, Nykamp M, Remund T, Kelly P. Treatment of a massive left femoral arteriovenous malformation using an innovative modular hybrid bifurcated stent graft system. Ann Vasc Surg. 2014 May;28(4):1031.e15-20. doi: 10.1016/j.avsg.2013.07.023. Epub 2013 Oct 31.

Reference Type RESULT
PMID: 24184461 (View on PubMed)

Narayanan S, Shalhoub J, Karunanithy N, Burfitt N. Primary suture-anastomosis of the Viabahn endoprosthesis to a native artery. J Vasc Surg. 2010 May;51(5):1297-9. doi: 10.1016/j.jvs.2009.12.045. Epub 2010 Mar 19.

Reference Type RESULT
PMID: 20303692 (View on PubMed)

Donas KP, Lachat M, Rancic Z, Oberkofler C, Pfammatter T, Guber I, Veith FJ, Mayer D. Early and midterm outcome of a novel technique to simplify the hybrid procedures in the treatment of thoracoabdominal and pararenal aortic aneurysms. J Vasc Surg. 2009 Dec;50(6):1280-4. doi: 10.1016/j.jvs.2009.06.053.

Reference Type RESULT
PMID: 19958984 (View on PubMed)

Oderich GS, Fatima J, Gloviczki P. Stent graft modification with mini-cuff reinforced fenestrations for urgent repair of thoracoabdominal aortic aneurysms. J Vasc Surg. 2011 Nov;54(5):1522-6. doi: 10.1016/j.jvs.2011.06.023. Epub 2011 Sep 16.

Reference Type RESULT
PMID: 21925826 (View on PubMed)

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

IP-01-001 Visceral Manifold

Identifier Type: -

Identifier Source: org_study_id

More Related Trials

Additional clinical trials that may be relevant based on similarity analysis.

Thoracoabdominal Aortic Aneurysms
NCT06267573 NOT_YET_RECRUITING
Zenith® TX2® Low Profile TAA Endovascular Graft
NCT02471781 APPROVED_FOR_MARKETING