Complex Aortic Aneurysm Repair Using Physician Modified Endografts and Custom Made Devices
NCT ID: NCT02050113
Last Updated: 2025-10-22
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
RECRUITING
NA
600 participants
INTERVENTIONAL
2014-03-31
2030-03-31
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
CAAAs, TAAAs, Aortic Arch Aneurysms or Dissections With Fenestrated/Branched Stent Graft
NCT02089607
Physician-modified Endovascular Graft for Repair of Complex Thoracoabdominal and Abdominal Aortic Aneurysms
NCT04526938
Endovascular Treatment of TAAA and Aortic Arch Aneurysms Using Fenestrated and Branched Stent Grafts
NCT02323581
Safety and Effectiveness of Physician-Modified Fenestrated and Branched Aortic Endografting for the Treatment of Thoracoabdominal and Pararenal Aortic Aneurysms
NCT06501872
Registry in Patients With Thoracoabdominal Aneurysms
NCT03295682
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
Determination of which type of endograft to use will be based on the patient's anatomy and the perceived urgency of the need for repair. This decision will be made by the study team and confirmed by a 3rd party reviewer who is not an investigator on the study team. After ensuring that a patient meets inclusion and exclusion criteria for participation in the CARPE-CMD study, the perceived urgency for repair will be evaluated given the 6-8 week required time for manufacture of a CMD device.
If the patient's aneurysm is not symptomatic and if, at the discretion of the treating surgeon, the patient is deemed safe to wait 8 weeks until repair, the patient will be considered non-urgent. Non-urgent patients will undergo repair with a CMD device.
If the patient's aneurysm is symptomatic and if, at the discretion of the treating surgeon, the patient is deemed unsafe to wait 8 weeks until repair, the patient will be considered urgent. Urgent patients will undergo repair with a t-branch device (if anatomy suitable) Urgent patients who do not have anatomy suitable to a t-branch device or patients who are not deemed safe to wait for the device to be obtained, will undergo repair with a physician modified device.
The device is inserted into the body through two small punctures or incisions in the groin. Small stents will be inserted through the stent graft fenestrations into the major blood vessels affected by the aneurysm so that blood flow is maintained to these organs.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
NA
SINGLE_GROUP
TREATMENT
NONE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
Endovascular repair
Endovascular repair of Complex Aortic Aneurysm using a physician modified stent graft. custom made device or arch branch device.
Custom Made Fenestrated or Branched Stent Graft
The surgeon will place a custom made graft, t-Branch device or modify commercially available stent grafts to match the anatomy of the patient being treated. Small fenestrations (holes) will be made in the stent graft so that additional stents can be inserted through the fenestration and into the blood vessels that lead to the kidneys, intestines or liver. These stents allow blood to flow freely to these organs. If the aneurysm is in the aortic arch stents may be placed in the carotid and subclavian arteries. This surgery is done through small incisions in the groin and sometimes in the upper arm.
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
Custom Made Fenestrated or Branched Stent Graft
The surgeon will place a custom made graft, t-Branch device or modify commercially available stent grafts to match the anatomy of the patient being treated. Small fenestrations (holes) will be made in the stent graft so that additional stents can be inserted through the fenestration and into the blood vessels that lead to the kidneys, intestines or liver. These stents allow blood to flow freely to these organs. If the aneurysm is in the aortic arch stents may be placed in the carotid and subclavian arteries. This surgery is done through small incisions in the groin and sometimes in the upper arm.
Other Intervention Names
Discover alternative or legacy names that may be used to describe the listed interventions across different sources.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
1. Aortic or aortoiliac aneurysm with diameter ≥5.5 cm
2. Aortic or aortoiliac aneurysm with a history of growth ≥1.0 cm per year, or clinical indication for aneurysm repair based on symptoms
<!-- -->
1. Cannot be treated with a currently available non-modified approved device
2. Symptomatic on presentation and unsafe to wait for the time necessary to obtain a currently available non-modified approved device
3. At least 18 years of age
4. Not pregnant or breastfeeding
5. Willing and able to comply with five years of follow-up
6. Willing and able to provide informed consent prior to enrollment
7. No systemic or local infection that may increase the risk of endovascular graft infection
8. High risk for open surgical repair based on any of the factors below:
a. Anatomic i. Previous abdominal surgery ii. Previous left-sided thoracotomy (if the proposed open repair would require dissection of the thoracic aorta) iii. Previous aortic surgery b. Physiologic i. ASA Category III or higher ii. Age \>70 years iii. Previous myocardial infarction, coronary artery disease, or coronary artery stent iv. Coronary stress test with a reversible perfusion defect v. Congestive heart failure vi. COPD
Exclusion Criteria
2. Allergy or sensitivity to stainless steel, polyester, polypropylene, solder (tin, silver), gold, or nitinol
3. Anaphylactic reaction to contrast that cannot be adequately pre-medicated
4. Uncorrectable coagulopathy
5. Unstable angina (defined as angina with a progressive increase in symptoms, new onset at rest or nocturnal angina, or onset of prolonged angina)
6. Patient has active malignancy with life expectancy of less than 2 years
7. Patient has life expectancy less than two years
1. Significant occlusive disease, tortuosity, or calcification that would prevent endovascular access
2. Proximal neck length ≤25 mm
3. Proximal neck, measured outer wall to outer wall on a sectional image (CT)
1. For use of Zenith Flex: diameter \>32 mm or \<18 mm
2. For use of Zenith TX2: diameter \>38 mm or \<24 mm (for proximal and distal neck diameter)
4. Proximal neck angulated more than 60 degrees relative to the long axis of the aneurysm
5. Proximal neck diameter change over the length of the proximal seal zone \>4 mm
6. Proximal seal site with a circumferential thrombus/atheroma
7. Iliac artery diameter, measured inner wall to inner wall on a sectional image (CT) \<7.0 mm at any point along access length (prior to deployment)
8. Ipsilateral iliac artery fixation site diameter, measured inner wall on a sectional image (CT) \>21 mm at distal fixation site
9. Iliac artery distal fixation site \<10 mm in length
10. Non-bifurcated segment of any artery to be stented \< 15 mm in length
11. Artery to be stented with a maximum diameter \<3 mm or \>10 mm at the vessel ostium
12. Inability to maintain at least one patent hypogastric artery
18 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Andres Schanzer
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Andres Schanzer
Principal Investigator
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
Andres Schanzer, MD
Role: PRINCIPAL_INVESTIGATOR
University of Massachusetts, Worcester
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
UMass Memorial Health Care - University Campus
Worcester, Massachusetts, United States
Countries
Review the countries where the study has at least one active or historical site.
Central Contacts
Reach out to these primary contacts for questions about participation or study logistics.
Facility Contacts
Find local site contact details for specific facilities participating in the trial.
References
Explore related publications, articles, or registry entries linked to this study.
Mesnard T, Huang Y, Schanzer A, Timaran CH, Schneider DB, Mendes BC, Eagleton MJ, Farber MA, Parodi FE, Gasper WJ, Beck AW, Sweet MP, Zetterval SL, Lee A, Oderich GS; United States Aortic Research Consortium. Multicenter Prospective Evaluation of Patient Radiation Exposure During Fenestrated-Branched Endovascular Aortic Repair: A Ten-year Experience. Ann Surg. 2025 Feb 18. doi: 10.1097/SLA.0000000000006676. Online ahead of print.
Oderich GS, Huang Y, Harmsen WS, Tenorio ER, Schanzer A, Timaran CH, Schneider DB, Mendes BC, Eagleton MJ, Farber MA, Gasper WJ, Beck AW, Sweet MP, Lee WA; United States Aortic Research Consortium. Early and Late Aortic-Related Mortality and Rupture After Fenestrated-Branched Endovascular Aortic Repair of Thoracoabdominal Aortic Aneurysms: A Prospective Multicenter Cohort Study. Circulation. 2024 Oct 22;150(17):1343-1353. doi: 10.1161/CIRCULATIONAHA.123.068234. Epub 2024 Jul 11.
Finnesgard EJ, Beck AW, Eagleton MJ, Farber MA, Gasper WJ, Lee WA, Oderich GS, Schneider DB, Sweet MP, Timaran CH, Simons JP, Schanzer A; United States Aortic Research Consortium. Severity of acute kidney injury is associated with decreased survival after fenestrated and branched endovascular aortic aneurysm repair. J Vasc Surg. 2023 Oct;78(4):892-901. doi: 10.1016/j.jvs.2023.05.034. Epub 2023 Jun 16.
Aucoin VJ, Motyl CM, Novak Z, Eagleton MJ, Farber MA, Gasper W, Oderich GS, Mendes B, Schanzer A, Tenorio E, Timaran CH, Schneider DB, Sweet MP, Zettervall SL, Beck AW; U.S. Aortic Research Consortium. Predictors and outcomes of spinal cord injury following complex branched/fenestrated endovascular aortic repair in the US Aortic Research Consortium. J Vasc Surg. 2023 Jun;77(6):1578-1587. doi: 10.1016/j.jvs.2023.01.205. Epub 2023 Apr 13.
Finnesgard EJ, Simons JP, Jones DW, Judelson DR, Aiello FA, Boitano LT, Sorensen CM, Nguyen TT, Schanzer A. Initial single-center experience using Fiber Optic RealShape guidance in complex endovascular aortic repair. J Vasc Surg. 2023 Apr;77(4):975-981. doi: 10.1016/j.jvs.2022.11.041. Epub 2022 Nov 13.
Alqaim M, Cosar E, Crawford AS, Robichaud DI, Walz JM, Schanzer A, Simons JP. Lumbar drain complications in patients undergoing fenestrated or branched endovascular aortic aneurysm repair: Development of an institutional protocol for lumbar drain management. J Vasc Surg. 2020 Nov;72(5):1576-1583. doi: 10.1016/j.jvs.2020.02.013. Epub 2020 Apr 2.
Schanzer A, Baril D, Robinson WP 3rd, Simons JP, Aiello FA, Messina LM. Developing a complex endovascular fenestrated and branched aortic program. J Vasc Surg. 2015 Mar;61(3):826-31. doi: 10.1016/j.jvs.2014.08.121. Epub 2015 Jan 13.