The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
RECRUITING
NA
15 participants
INTERVENTIONAL
2017-08-01
2029-05-31
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Visceral Manifold Study for the Repair of Thoracoabdominal Aortic Aneurysms
NCT03113383
Clinical Study of the TriVascular Ovation™ Abdominal Stent Graft System
NCT01092117
Clinical Study of the Treovance Stent-Graft for Patients With Abdominal Aortic Aneurysms
NCT02009644
Endovascular Repair of Abdominal Aortic Aneurysms
NCT00803075
Endovascular Repair of Thoracoabdominal Aortic Aneurysms
NCT04009512
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
Patients who participate in this study may benefit from having a less invasive procedure compared to open repair of their thoracoabdominal aortic aneurysm. The Investigator expects the amount of discomfort, total blood loss, recovery time, and overall hospital stay to be less than open repair. Many of the patients presenting with a thoracoabdominal aneurysm are not candidates for open repair due to existing comorbidities. With the progressive nature of the disease, these patients have limited options for medical intervention and are willing to assume a higher amount of risk.
The Medtronic Valiant Thoracoabdominal Stent Graft System is made up of two main body components and makes use of several off-the-shelf FDA-approved stent graft components. The two custom main body grafts are the thoracic bifurcation and the visceral manifold. The thoracic bifurcation is deployed in the thoracic aorta and provides the proximal seal for the device. For a Type I or II thoracoabdominal aneurysm the proximal seal is in zone 3, for Type III and V the device seals in zone 4. The two limbs of the thoracic bifurcation allows for continued aortic flow while deploying the visceral segment. The visceral manifold is deployed within the larger 20 mm limb of the thoracic bifurcation to set the stage for the visceral debranching. The branches of the visceral manifold extend to the visceral vessel with the use of covered bridging stents and provide distal seal of the manifold. The smaller 16 mm limb of the thoracic bifurcation extends to the infrarenal segment to either seal in zone 9 for a Type I and V and in zone 10 for Type II and III. All other connections in the device make use of sizes that are modular and independent of patient anatomy.
The Medtronic Valiant Thoracoabdominal Stent Graft works to bifurcate aortic flow upstream of the target visceral vessels. This bifurcation has a two-fold benefit. First it allows for aortic flow to be compartmentalized into a visceral segment and an infrarenal segment providing for uninterrupted flow to the visceral vessels as well as the infrarenal segment throughout the procedure. If any of the connections cannot be made or the patient status declines during the procedure, then it can be staged and the connections can be made at a later date. Second, the upstream bifurcation encourages more favorable flow conditions in the bridging stents and target vessels which may prevent target vessel occlusion. This is due to the fact that the bifurcations are upstream providing a sweeping transition into the renal arteries that is smooth providing for relatively laminar flow conditions. The design demonstrates that more central aortic flow is obtained with this design increasing flow rates in the visceral vessels to potentially increase target vessel patency.
The device can be used as an off-the-shelf system, negating the need for lead times associated with custom-built devices. The critical sizing will need to be done with the proximal end of the thoracic bifurcation, distal landing zone in the aorta or iliac arteries, and the bridging stents. The proximal end of the thoracic bifurcation can be sized by choosing any of the available sizes of the Medtronic TAAA thoracic bifurcation stent grafts, and the sizes of the bridging stents can be manipulated by choosing any of the commercially available sizes of the Atrium iCast. The Atrium iCasts are added to the system in-vivo and connected with passive fixation which negates the need to size the main body components based on the target vessel sizes. All other connections in the device make use of sizes that are the same, independent of patient anatomy.
The deployment of this device is also independent of device alignment. Angular alignment of the thoracic bifurcation and the visceral manifold has very little impact on the outcome of the case. Longitudinal alignment is more important, but a safety factor has been built-in by calling for the distal ends of the visceral manifold to be deployed above their target vessels by 1-2 cm. The longitudinal landing should be optimized so that the graft is not landed too low that the connection with the visceral vessels is challenging to make.
Patients included in the study will undergo follow-up at one month, six months, twelve months and then annually for five years.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
NON_RANDOMIZED
PARALLEL
TREATMENT
NONE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
Primary Study Arm
Patients meeting primary inclusion/exclusion criteria will be enrolled in this arm and treated with the Medtronic Valiant Thoracoabdominal Stent Graft System.
Medtronic Valiant Thoracoabdominal Stent Graft System
The Medtronic Valiant Thoracoabdominal Stent Graft System is made up of two main body components and makes use of several off-the-shelf FDA-approved stent graft components The system is comprised of two investigational devices that include the thoracic bifurcation and the visceral manifold. The thoracic bifurcation is deployed in the thoracic aorta and provides the proximal seal for the device. The two limbs of the thoracic bifurcation allows for continued aortic flow while deploying the visceral segment. The visceral manifold is deployed within the larger 20 mm limb of the thoracic bifurcation to set the stage for the visceral debranching. The branches of the visceral manifold extend to the visceral vessel with the use of covered bridging stents and provide distal seal of the manifold.
Expanded Selection Arm
Patients who fail to meet the inclusion criteria of the Primary Study Arm may be enrolled under the Expanded Selection Arm and be treated with the Medtronic Valiant Thoracoabdominal Stent Graft System.
Medtronic Valiant Thoracoabdominal Stent Graft System
The Medtronic Valiant Thoracoabdominal Stent Graft System is made up of two main body components and makes use of several off-the-shelf FDA-approved stent graft components The system is comprised of two investigational devices that include the thoracic bifurcation and the visceral manifold. The thoracic bifurcation is deployed in the thoracic aorta and provides the proximal seal for the device. The two limbs of the thoracic bifurcation allows for continued aortic flow while deploying the visceral segment. The visceral manifold is deployed within the larger 20 mm limb of the thoracic bifurcation to set the stage for the visceral debranching. The branches of the visceral manifold extend to the visceral vessel with the use of covered bridging stents and provide distal seal of the manifold.
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
Medtronic Valiant Thoracoabdominal Stent Graft System
The Medtronic Valiant Thoracoabdominal Stent Graft System is made up of two main body components and makes use of several off-the-shelf FDA-approved stent graft components The system is comprised of two investigational devices that include the thoracic bifurcation and the visceral manifold. The thoracic bifurcation is deployed in the thoracic aorta and provides the proximal seal for the device. The two limbs of the thoracic bifurcation allows for continued aortic flow while deploying the visceral segment. The visceral manifold is deployed within the larger 20 mm limb of the thoracic bifurcation to set the stage for the visceral debranching. The branches of the visceral manifold extend to the visceral vessel with the use of covered bridging stents and provide distal seal of the manifold.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
1. an aneurysm with a maximum diameter of \> 5.5 cm or 2 times the normal diameter just proximal to the aneurysm using orthogonal (i.e., perpendicular to the centerline) measurements
2. aneurysm with a history of growth \> 0.5 cm in 6 months
3. saccular aneurysm deemed at significant risk for rupture
4. symptomatic aneurysm greater than 4.5 cm
2. Axillary or brachial and iliac or femoral access vessel morphology that is compatible with vascular access techniques, devices or accessories, with or without use of a surgical conduit.
3. Proximal landing zone for the thoracic bifurcation stent graft that has:
1. ≥ 2.5 cm of nonaneurysmal aortic segment including previously placed graft material (neck) distal to the left subclavian artery (LSA) diameter in the range of 26-42 mm.
2. adequate distance from the celiac artery, in order to accommodate cannulation from the antegrade access point when considering the total deployed length of the thoracic bifurcation and visceral manifold.
4. Minimum branch vessel diameter ≥ 5 mm.
5. Iliac artery or aortic distal fixation site, including both native tissue and previously placed graft, greater than or equal to 15 mm in length and diameter in the range of 8 - 25 mm.
6. Patient is ≥ 18 years of age.
7. Patient has a life expectancy \> 1 year.
1. Patient that meets the criteria for inclusion in the primary study arm but has one or more of the following criteria which would exclude them from the primary study arm:
1. Patient has a minimum branch vessel diameter less than 5 mm.
2. Patients presents urgently or emergently.
3. Patient has a contained rupture.
4. Patient has a ruptured aneurysm.
5. Patient has a type B dissection (subacute or chronic) in the portion of the aorta intended to be treated.
6. Patient has poor performance status including two major system failures (cardiovascular, pulmonary, renal, hepatobiliary, and neuromuscular).
7. Patient's baseline creatinine greater than 2.0 mg/dL.
8. Patient's anatomy that would not allow for maintenance of at least one hypogastric artery.
9. Patient's anatomy that would not allow for primary or assisted patency of the left subclavian artery.
Or
2. Patient that meets the criteria for inclusion in the primary study arm and:
1. Would not be eligible for the primary study arm per a documented reason other than those outlined above, and
2. Per the opinion of the Principal Investigator, with concurrence of the IRB, alternative therapies are unsatisfactory and the probable risk of using the investigational device is no greater than the probable risk from the disease or condition.
Exclusion Criteria
2. Patient can be treated in accordance with the instructions for use with a legally marketed endovascular prosthesis.
3. Patient is eligible for enrollment in a manufacturer-sponsored IDE at the investigational site.
4. Patient is unwilling to comply with the follow-up schedule.
5. Patient is unable or refuses to give informed consent.
6. Urgent or emergent presentation.
7. Patient is pregnant or breastfeeding.
8. Patient has a contained rupture.
9. Patient has a ruptured aneurysm.
10. Patient has a dissection in the treated portion of the aorta.
11. Obstructive stenting of any or all of the visceral vessels.
12. Poor performance status including 2 major system failures (cardiovascular, renal, hepatobiliary, neuromuscular).
1. Patient has known sensitivities or allergies to the materials of construction of the devices, including nitinol (Nickel: Titanium), polyester, platinum-iridium, polytetrafluoroethylene (PTFE), platinum, gold, polyethylene, or stainless steel.
2. Patient has known hypersensitivity or contraindication to anticoagulation or contrast media that cannot be adequately medically managed.
3. Patient has an uncorrectable coagulopathy.
4. Patient has a body habitus that would inhibit x-ray visualization of the aorta or exceeds the safe capacity of the equipment.
5. Patient has had a major surgical or interventional procedure. unrelated to the treatment of the aneurysm planned \< 30 days of the endovascular repair.
6. Patient has unstable angina (defined as angina with a progressive increase in symptoms, new onset at rest or nocturnal angina).
7. Patient has a systemic or local infection that may increase the risk of endovascular graft infection.
8. Baseline creatinine greater than 2.0 mg/dL.
9. History of connective tissue disorders (e.g., Marfan Syndrome, Ehler's Danlos Syndrome).
1. Thrombus or excessive calcification within the neck of the aneurysm.
2. Anatomy that would not allow maintenance of at least one patent hypogastric artery.
3. Anatomy that would not allow primary or assisted patency of the left subclavian artery.
Expanded Selection Criteria:
18 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Medtronic
INDUSTRY
The Christ Hospital
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Geoffrey Answini
Dr.
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
Geoffrey Answini, MD
Role: PRINCIPAL_INVESTIGATOR
The Christ Hospital
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
The Christ Hospital
Cincinnati, Ohio, United States
Countries
Review the countries where the study has at least one active or historical site.
Central Contacts
Reach out to these primary contacts for questions about participation or study logistics.
Facility Contacts
Find local site contact details for specific facilities participating in the trial.
Geoffrey Answini, MD
Role: primary
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
ISR-2016-10790
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.