Gas Mask and Chronic Obstructive Pulmonary Disease (COPD): New Understanding on the Respiratory Index Impact?
NCT ID: NCT02809807
Last Updated: 2016-09-29
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
COMPLETED
NA
9 participants
INTERVENTIONAL
2016-06-30
2016-07-31
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Effect of Home-base Exercise With Conical-PEP Device on Physical Performance and Quality of Life in COPD
NCT02790047
Interfaces of Non-invasive Ventilation on Performance in Patients With Chronic Obstructive Pulmonary Disease
NCT02796599
The Effect of Mask Design on Ventilation Parameters in COPD and OHS Patients on Long-term Home Non-invasive Ventilation. An Experimental Study.
NCT06972589
Inspiratory Muscle Training Combined With General Exercise Training in COPD
NCT02392715
Resistance Training to Prehabilitate Patients With Chronic Obstructive Pulmonary Disease
NCT02860728
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
The military gas mask is part of the respirator classification but owes its specific features. Conventionally, the military gas mask covers a large spectrum of protection aspects and matched with their specific canisters. Consequently, gas masks are usually studied separately from other respirators and Self-Contained Breathing Apparatus (SBCA). While few studies have been about the gas mask technology, no-study addresses it in regards of the impact from a bad airway protection and consequences on the respiratory system.
The gas mask design and its components may lead to these respiratory load issues. At rest and from different resistances, what would be the impacts for the work of breathing and gas exchange? In order to avoid hypoxemia and hyperoxia, what would be the optimal means to restore proper oxygenation? We hypothesised on a: i. Heightened WOB and the respiratory demands related to wear of the gas mask; ii. An occurrence of hypoxemia will be manifesting during a continuous period. Our goal is to measure the impact of the work of breathing and the gas exchange for a gas mask user and also a COPD patient. We also measure what was the optimal means for correcting the hypoxemia with a subject.
9 COPD patients have been participating in a comparison and single-blind randomized experimental study. That was approved by the Ethical Review Committee. A written consent is obtained for all the subjects prior their acceptance. No rejection has happened during the recruiting so far. The eligibility criteria are: i. COPD diagnosis from mild-to-severe FEV 30-80%). The exclusion criteria are: i. Refusals relate to wear the oesophageal catheter and for capillary punctures; ii. Claustrophobia; iii. Oesophageal wounds backgrounds; iv. No coronary background and stroke history; v. No face morphology incompatibility with the mask. Spirometry and usual health screening is also done before starting the clinical trial.
Design comprises three 10-minute testing conditions split in two parts. All has been at rest and sitting on a chair: i. Baseline without gas mask; ii. Gas mask and Canister A; iii. Gas Mask and Canister B. Between the condition a 5-minute wash-out takes place.
Three five-minute periods is followed to record blood pressure and pulse during the conditions. SpO2 is continuously measured with Free O2. Capillary punctures are done at the end of each condition. Comfort was also assessed.
Our main measurements are the WOB performed with a continuous recording of Peso pressure and respiratory volumes. Software Acknowledge, version 3.9 serves as acquisition data system and analysis are achieved with a 4.2 version and a free-trial WOB calculus system, named RESPMAT. That is obtained from Maynaud and al.(2014). As power source, we use a BIOPAC (MP100, Santa Barbara, Californie, USA, 200 Hertz), four differential sensors (Validyne : 1x MP45±100 cmH2O; 2x MP100±5 cmH2O; 1x MP100±100 cmH2O) and four Carrier D-Modulators (Validyne, CT-15,120 Volt, 60 Hertz, 5Watts, Model CD15-A-2-A-1).
Single esophageal catheter (Type Cooper, French caliber #5) and disposable pneumotachs are used. Lidocain spray and K-Y gel are applied during the insertion of the catheter. Its placement is done at 37.6±5.7 cm across the subject and a Mueller test is performed for each subject. In regard of spontaneous breathing, an Hudson mask is used while a C-4 Gas Mask with a canister was employed (Manufacturer: Airboss Defence, Bromont, Canada). Canister A and B were respectively a C7A1 and ADB81 trademark. Prototyped Free O2 System is employed for the correction of the hypoxemia.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
RANDOMIZED
SINGLE_GROUP
HEALTH_SERVICES_RESEARCH
SINGLE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
Baseline
Without a gas mask. We measure baseline respiratory index, parameters and the comfort.
measurement of the work of breathing
We have been evaluating breathing patterns, index of respiratory efforts and blood gases in all randomized conditions. Airway pressure, inspiratory and expiratory flows have been measured. An esophageal catheter has been introduced at the beginning of the study to measure esophageal pressure (Peso) and calculate indexes of respiratory effort (PTPeso, WOB). SpO2 has been continuously measured and capillary blood bases were drawn at the end of each condition. Comfort has also been assessed. FreeO2 System has been used and pre-programmed in accordance with the patient SpO2 target zone for potential correction of the hypoxemia occurrences. Differences among randomized conditions are one without gas mask as for the baseline and two with gas masks but different canisters.
Assessment with gas mask and canister A
With a gas mask, the measurement have been done with a high resistive canister. We measure baseline respiratory index, parameters and the comfort. These would serve for conduction comparison with the baseline.
measurement of the work of breathing
We have been evaluating breathing patterns, index of respiratory efforts and blood gases in all randomized conditions. Airway pressure, inspiratory and expiratory flows have been measured. An esophageal catheter has been introduced at the beginning of the study to measure esophageal pressure (Peso) and calculate indexes of respiratory effort (PTPeso, WOB). SpO2 has been continuously measured and capillary blood bases were drawn at the end of each condition. Comfort has also been assessed. FreeO2 System has been used and pre-programmed in accordance with the patient SpO2 target zone for potential correction of the hypoxemia occurrences. Differences among randomized conditions are one without gas mask as for the baseline and two with gas masks but different canisters.
Gas Mask
Differences among randomized conditions are one without gas mask as for the baseline and two with gas masks but different canisters.
Assessment with gas mask and canister B
With a gas mask, the measurement have been done with a low resistive canister. We measure baseline respiratory index, parameters and the comfort. These would serve for conduction comparison with the baseline.
measurement of the work of breathing
We have been evaluating breathing patterns, index of respiratory efforts and blood gases in all randomized conditions. Airway pressure, inspiratory and expiratory flows have been measured. An esophageal catheter has been introduced at the beginning of the study to measure esophageal pressure (Peso) and calculate indexes of respiratory effort (PTPeso, WOB). SpO2 has been continuously measured and capillary blood bases were drawn at the end of each condition. Comfort has also been assessed. FreeO2 System has been used and pre-programmed in accordance with the patient SpO2 target zone for potential correction of the hypoxemia occurrences. Differences among randomized conditions are one without gas mask as for the baseline and two with gas masks but different canisters.
Gas Mask
Differences among randomized conditions are one without gas mask as for the baseline and two with gas masks but different canisters.
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
measurement of the work of breathing
We have been evaluating breathing patterns, index of respiratory efforts and blood gases in all randomized conditions. Airway pressure, inspiratory and expiratory flows have been measured. An esophageal catheter has been introduced at the beginning of the study to measure esophageal pressure (Peso) and calculate indexes of respiratory effort (PTPeso, WOB). SpO2 has been continuously measured and capillary blood bases were drawn at the end of each condition. Comfort has also been assessed. FreeO2 System has been used and pre-programmed in accordance with the patient SpO2 target zone for potential correction of the hypoxemia occurrences. Differences among randomized conditions are one without gas mask as for the baseline and two with gas masks but different canisters.
Gas Mask
Differences among randomized conditions are one without gas mask as for the baseline and two with gas masks but different canisters.
Other Intervention Names
Discover alternative or legacy names that may be used to describe the listed interventions across different sources.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
Exclusion Criteria
* Oesophageal background wounds
* Facial anthropometrical issues.
45 Years
75 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Captain (retired) Stephane Bourassa, RN CD
UNKNOWN
Mr Pierre-Alexandre Boucard, RT
UNKNOWN
Laval University
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
François Lellouche
Research Director
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
Francois Lellouche, PhD
Role: PRINCIPAL_INVESTIGATOR
Laval University
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Institut de Recherche Universitaire de Cardiologie et Pneumologie de Québec
Québec, Quebec, Canada
Countries
Review the countries where the study has at least one active or historical site.
References
Explore related publications, articles, or registry entries linked to this study.
Bourassa S, Bouchard PA, Dauphin M, Lellouche F. Oxygen Conservation Methods With Automated Titration. Respir Care. 2020 Oct;65(10):1433-1442. doi: 10.4187/respcare.07240. Epub 2020 Feb 18.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
21140MPOC
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.