Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
UNKNOWN
NA
10 participants
INTERVENTIONAL
2016-03-31
2017-02-28
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
HTO involves cutting a wedge out the tibia to correct the alignment of that bone with the knee joint, to redistribute load from the affected medial part to lateral part. To keep the tibia in the new position, a medical nail device is attached to keep it in place and allow new bone to regenerate within the wedge. Currently, the market leader for HTO is the TomoFix (by DePuySynthes company) plate and nail device. As the name suggests, TomoFix is fixed at surgery and therefore the change in bone angle cannot be changed afterwards. It does mean that patients can be weight-bearing on the affected leg soon after the HTO procedure. A new CE-marked device is being tested in an interventional trial; it is produced by Ellipse Technologies. This device is an extendable nail and inserted intramedullary; following surgery the nail is tend slowly extended over a period of time until the bone correction is satisfactory.
The CISKO imaging study will assess whether there is a difference between the TomoFix and Ellipse system in terms of bone regeneration in the tibial wedge by performing a CT-scan at 3 and 6 months post-operatively. This will be quantified by two independent radiological reports. A secondary objective is to investigate patient satisfaction and also patient pain levels at these time intervals. The degree of bone healing is usually the main factor holding clinicians back when it comes to advising patients on what activities they can return to post-operatively. A difference in bone healing between the two systems may impact on the advice clinicians can give patients regarding recommencing more intense activities such as recreational sports, which ultimately could positively impact patients' health and well-being.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
MR Imaging of Knee Osteoarthritis and Acute Knee Injuries
NCT00504114
Ellipse Intramedullary Nail High Tibial Osteotomy Study
NCT02412163
Correction of Angular Deformities in Knee Arthrosis
NCT02581605
Total Knee Replacement Component Alignment Using Manual Versus Custom Instrumentation
NCT02579174
Use of a Novel Weight Bearing Cone Beam Computed Tomography (CBCT) Scanner for Imaging of the Patellofemoral Joint
NCT02762630
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
It is imperative that the open wedge is healed and repopulated by new bone, to strengthen the tibia and allow full recovery following HTO. Regeneration will take place naturally, although some surgeons apply aids to promote bone healing, such as the ChronOS β-tricalcium phosphate wedge. However, research into this aspect of filling the wedge has shown that there is no advantage to using the filler - both in terms of stability and bone healing time of the wedge . Although fixed systems like Tomofix facilitate early weight-bearing of the affected joint, the complete closure and consolidation of the wedge takes considerably longer. In one study, 23 /27 (85%) osteotomies were fully healed twelve months after procedure . Histologically, there is variability in the degree of healing and indeed maturation of bone regeneration achieved in the tibial wedge. With current fixed plate devices, even two years post-procedure, a minor subset of patients will not have significant signs of regeneration in the surgical site. In the majority of patients, partial bone regeneration with fibrocartilaginous tissue takes place and in some patients by new regenerated fibrocartilage or hyaline-like cartilage will appear .
HTO could be improved upon to allow an earlier return to activities by patients and to achieve better rates of healing - both in terms of time and maturity of the regenerated bone. Ellipse Technologies have devised a new nail system for high tibial osteotomy that differs from the established 'locked' plate and nail systems. Their system functions in a more gradual fashion. The wedge is created in the tibia as per normal but then the Ellipse nail is inserted and per day the nail is extended in small measures (appr 1.5 mm per day) until the desired correction has been achieved. Currently the new Ellipse system is being trialed in various countries in Europe, including the Netherlands and the UK. The main Ellipse trial is seeking to establish whether the corrective power of this medical device is more accurate than the plate/nail systems in use at present. The degree of bone regeneration in the open wedge is reported on, but not in detail - e.g. by one reporting radiologist - and by using standard X-ray imaging which is primarily used for angle measurements.
This present study seeks to explore in more detail how the Tomofix and Ellipse high-tibial osteotomy systems function in relation to bone regeneration in the open-wedge created as part of the procedure by utilising CT imaging techniques rather than standard clinical X-ray imaging. The primary aim of osteotomy is realignment of the joint and thereby preserves the joint so that the patient can continue to enjoy the active life style, sports and recreational activities. After an osteotomy procedure, whenever a patient asks for advice to the clinician when they can start participating in unrestricted sports activities, clinicians often find it very difficult to answer this question. This is primarily because it is often very difficult to quantify the bone healing process precisely on radiographs. By quantifying the amount of bone healing on CT scan which is more clear and accurate, the clinician can confidently advise the patient regarding the participation in various sports activities without ambiguity.
Further, by comparing the bone healing process between Tomofix plate and Ellipse nail, investigators can make more informed judgement regarding their performance. This research will also enhance the choice of implant selection in osteotomy patients based on the duration of bone healing.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
NON_RANDOMIZED
PARALLEL
DIAGNOSTIC
NONE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
CT scan Ellipse
New medical device for high tibial osteotomy
Ellipse
diagnostic CT scan imaging
CT scan Tomofix
Established medical device for high tibial osteotomy
Tomofix
diagnostic CT scan imaging
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
Ellipse
diagnostic CT scan imaging
Tomofix
diagnostic CT scan imaging
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
2. Males
3. Mental capacity
Exclusion Criteria
2. Patients lacking mental capacity.
3. Females
4. Current use of nicotine products.
5. Patients who cannot understand English and therefore cannot be consented.
1. Varus deformity greater than 10°
2. Flexion contracture greater than 15°
3. Knee flexion under 90°
4. Medial/lateral tibial subluxation over 1 cm
5. Medial bone loss of over 3 mm
6. Inflammatory arthritis (including use of methotrexate)
7. Arthritis in the lateral compartment
8. Patella baja
9. Weight over 114 kg
10. Severe patella femoral symptoms
11. Unaddressed ligamentous instability
12. Fixed flexion contracture
13. Known or suspected osteoporosis or osteopenia based on medical history and radiographic image
14. Requires other surgical procedures at the time of the HTO surgery -
18 Years
100 Years
MALE
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
NuVasive
INDUSTRY
North Cumbria University Hospitals NHS Trust
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
Chris Hafner, PhD
Role: STUDY_DIRECTOR
NuVasive
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Cumberland Infirmary
Carlisle, Cumbria, United Kingdom
Countries
Review the countries where the study has at least one active or historical site.
Central Contacts
Reach out to these primary contacts for questions about participation or study logistics.
Facility Contacts
Find local site contact details for specific facilities participating in the trial.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
16/NW/0038
Identifier Type: OTHER
Identifier Source: secondary_id
PR0251
Identifier Type: -
Identifier Source: org_study_id