Surgical Outcomes of the Accelerometer-based Navigation System for Total Knee Arthroplasty

NCT ID: NCT04037228

Last Updated: 2023-12-07

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

RECRUITING

Total Enrollment

40 participants

Study Classification

OBSERVATIONAL

Study Start Date

2020-04-30

Study Completion Date

2024-12-31

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

Osteoarthritis (OA) is a very common condition in the elderly population. Treatment for end-stage OA is total knee Replacement (TKR)

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

Overall the success rate of TKR is very high with high patient satisfaction and outcomes. Survivorship depends on patient selection and surgical techniques. Femoral and tibial component mal-alignment might lead to early failure.

Although recent studies have questioned the significance of overall postoperative mechanical alignment on survivorship, most studies still demonstrate alignment to be a crucial factor in the clinical success of TKA \[1\]. Ritter et al \[2\], in a review of 6070 TKAs, noted the risk of aseptic failure to significantly increase with a tibial component orientation less than 90° relatives to the tibial axis and a femoral component orientation greater than 8° of valgus relative to the femoral axis (failure rate, 8.7%).

Berend et al \[3\], in a review of 3152 TKAs, demonstrated that a tibial varus alignment of greater than 3° increased the odds of implant failure and medial bone collapse by roughly 17 times.

The most commonly used methods of component alignment in TKA are an extramedullary (EM) alignment guide for the tibial resection and an intramedullary (IM) alignment guide for the distal femoral resection. Unfortunately, these "conventional" methods have demonstrated a limited degree of accuracy for both overall mechanical alignment and individual component Method to create an even more accurate resection includes the use computer-assisted navigation technique. In a meta-analysis of 29 studies comparing computer assisted surgical (CAS) to conventional techniques in TKA (Mason et al). The authors found that only 68.2% of TKAs in the conventional group achieved an overall mechanical axis within 3° of neutral (vs 91.0% in the CAS group), 65.9% achieved a femoral varus/valgus alignment within 2° of perpendicular to the femoral mechanical axis (vs 90.4% in the CAS group) and 79.7% achieved a tibial varus/valgus alignment within 2° of perpendicular to the tibial mechanical axis (vs 95.2% in the CAS group).

However, despite these advantages, concerns regarding increased capital costs, operative times, extra pin sites, and the learning curve associated with the use of CAS techniques have continued to limit its widespread acceptance.

Another factor that might have limited its usage is that so far no study has shown the accuracy with CAS can directly lead to a longer survivorship of the implant or a better functional outcome. However, the most surgeon still believes a correct align knee will yield a better function and outcome.

This shed the light to a new navigation device. Iorio et.al \[4\]The KneeAlign 2 system (OrthAlign Inc, Aliso Viejo, California) is an accelerometer-based, portable navigation device for TKA that attempts to combine the alignment accuracy of large-console CAS systems, with the ease of use and convenience of conventional alignment methods. It is used to perform the proximal tibial and distal femoral resections in TKA. It does not require the use of a large console for registration and alignment feedback and is compatible with any TKA system. It consists of a disposable display console (2 × 4 × 2 inches in size) and a reference sensor, both of which are used for the tibial and femoral resections The KneeAlign 2 is the second version of the KneeAlign originally developed to perform only the proximal tibia resection in TKA. The KneeAlign 2 required the additional design of a femoral jig and cutting block and allows for the use of the same display console to perform both the proximal tibia and distal femur resections. The display console and reference sensor each contains triaxial accelerometers that communicate wirelessly with one another. The surgical technique for using the KneeAlign 2 to perform the tibial resection is the same as previously described Briefly, the tibial jig has 2 primary components (a fixed component and a mobile component) connected by a proximal articulation .The fixed component, with the attached reference sensor, is first pinned to the tibia. The purpose of the fixed component is to account for the movement of the tibia during cutting block alignment.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Arthroplasty; Replacement; Knee Radiotherapy; Image-Guided

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Observational Model Type

COHORT

Study Time Perspective

PROSPECTIVE

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

KneeAlign 2

Those of the group will be adopt KneeAlign 2: accelerometer-based navigation system at total knee arthroplasty.

KneeAlign 2 system (OrthAlign Inc, Aliso Viejo, California)

Intervention Type DEVICE

The KneeAlign 2 system (OrthAlign Inc, Aliso Viejo, California) is an accelerometer-based, portable navigation device for TKA that attempts to combine the alignment accuracy of large-console CAS systems, with the ease of use and convenience of conventional alignment methods. It is used to perform the proximal tibial and distal femoral resections in TKA. It consists of a disposable display console (2 × 4 × 2 inches in size) and a reference sensor, both of which are used for the tibial and femoral resections The display console and reference sensor each contains triaxial accelerometers that communicate wirelessly with one another. Briefly, the tibial jig has 2 primary components (a fixed component and a mobile component) connected by a proximal articulation .The fixed component, with the attached reference sensor, is first pinned to the tibia. The purpose of the fixed component is to account for the movement of the tibia during cutting block alignment.

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

KneeAlign 2 system (OrthAlign Inc, Aliso Viejo, California)

The KneeAlign 2 system (OrthAlign Inc, Aliso Viejo, California) is an accelerometer-based, portable navigation device for TKA that attempts to combine the alignment accuracy of large-console CAS systems, with the ease of use and convenience of conventional alignment methods. It is used to perform the proximal tibial and distal femoral resections in TKA. It consists of a disposable display console (2 × 4 × 2 inches in size) and a reference sensor, both of which are used for the tibial and femoral resections The display console and reference sensor each contains triaxial accelerometers that communicate wirelessly with one another. Briefly, the tibial jig has 2 primary components (a fixed component and a mobile component) connected by a proximal articulation .The fixed component, with the attached reference sensor, is first pinned to the tibia. The purpose of the fixed component is to account for the movement of the tibia during cutting block alignment.

Intervention Type DEVICE

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

* Male and female subjects aged over 18 years old
* All patients must provide their written consent
* patients with a history of osteoarthritis, rheumatoid arthritis, or post-traumatic arthritis who will receive a primary, posterior-stabilized TKA.
* All patients should have at least 8 years of school education;
* Radiological evidence of osteoarthritis with Kellgren and Lawrence grade 2 or above

Exclusion Criteria

* Patients are planned to receive a unicondylar or patellofemoral arthroplasty.
* Patients with previous cases of alcoholism or drug abuse;
* Pregnancy and breast-feeding;
* Presence of serious pathologies;
* revision surgery
* Knee infection
* Non-consenting patients who have not provided the written Informed Consent;
* Mechanical instability, ligamentous laxity/deficiency and gross deformity
Eligible Sex

ALL

Accepts Healthy Volunteers

No

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

Chinese University of Hong Kong

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Dr. Ho Ki Wai

Clinical Professional Consultant

Responsibility Role PRINCIPAL_INVESTIGATOR

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

Department of Orthopaedics & Traumatology

Hong Kong, , Hong Kong

Site Status RECRUITING

Countries

Review the countries where the study has at least one active or historical site.

Hong Kong

Facility Contacts

Find local site contact details for specific facilities participating in the trial.

Ki Wai Ho, MBChB, MSc, MRCSEd, FRCSEd

Role: primary

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

2017.458

Identifier Type: -

Identifier Source: org_study_id