Comparison of nanOss Cervical IBF System to C-Plus PEEK IBF Device With Autograft

NCT ID: NCT02586116

Last Updated: 2020-07-27

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

COMPLETED

Clinical Phase

NA

Total Enrollment

11 participants

Study Classification

INTERVENTIONAL

Study Start Date

2015-10-31

Study Completion Date

2019-03-31

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

This is a post-market, prospective, randomized clinical investigation to evaluate the performance of the nanOss Cervical Interbody Fusion (IBF) device with nanOss Bioactive Bone Void Filler for the treatment of cervical disc disease. A secondary objective is to compare the performance of the nanOss Cervical IBF Device and nanOss Bioactive Bone Void Filler with the performance of the C-Plus PEEK IBF Device with autograft. This study will enroll 40 patients at one (1) site. After subjects have signed an informed consent, they will be randomly assigned to either the nanOss Cervical IBF device arm or the C-Plus PEEK IBF Device. Patients will complete the preoperative visit and examinations. Patients will be evaluated at discharge, six (6) weeks, three (3) months, six (6) months, and twelve (12) months. Patients will be evaluated at twenty-four (24) months post-operatively if they have not demonstrated fusion at the 12 month time point.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

The nanOss Cervical Interbody Fusion Device is CE-marked for single level intervertebral body fusion from C3 to T1 for the treatment of cervical disc disease. The nanOss IBF device is designed to be used as one device per level, with graft material and supplemental fixation.

nanOss BABone Void Filler is a resorbable porous calcium phosphate bone void filler for use as a bone graft substitute or bone void filler. It is CE marked for use as a bone void filler in the spine, and it is to be re-hydrated with Bone Marrow Aspirate (BMA) alone, or a mixture of the patient's BMA and autograft.

The C-Plus PEEK IBF Device is indicated for use in skeletally mature adults at one level in the cervical spine, from C3 to T1, for the treatment of cervical disc disease. The device is to be used in patients who have had six weeks of non-operative treatment. Autogenous bone graft is placed within the central cavity of the C-Plus PEEK IBF Device.

The SlimFuse Cervical Plate System components are titanium alloy plates and screws designed to temporarily provide resistance to flexion, extension, lateral bending and axial rotation with strength and stiffness in the cervical spine (C2-C7) in order to promote cervical fusion. The anterior approach should be used when implanting the SlimFuse Cervical Plate System.

The primary goal of this study is to evaluate the outcomes between nanOss Cervical IBF Device and C-Plus PEEK IBF Device. The primary endpoint will be objectively determined via x-rays and CT scan to assess fusion. Secondary endpoints will include subjective patient scores for neck and arm pain and quality of life along with analysis of the proportion of patients who experience a treatment failure.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Intervertebral Disc Degeneration

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Allocation Method

RANDOMIZED

Intervention Model

PARALLEL

Primary Study Purpose

TREATMENT

Blinding Strategy

SINGLE

Participants

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

nanOss

nanOss Cervical IBF System with nanOss BA Bone Void Filler

Group Type ACTIVE_COMPARATOR

nanOss

Intervention Type DEVICE

nanOss Cervical Interbody Fusion Device with nanOss BA bone void filler.

C-Plus

C-Plus PEEK IBF Device with autograft

Group Type ACTIVE_COMPARATOR

C-Plus

Intervention Type DEVICE

C-Plus PEEK IBF Device with autograft

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

nanOss

nanOss Cervical Interbody Fusion Device with nanOss BA bone void filler.

Intervention Type DEVICE

C-Plus

C-Plus PEEK IBF Device with autograft

Intervention Type DEVICE

Other Intervention Names

Discover alternative or legacy names that may be used to describe the listed interventions across different sources.

nanOss Cervical IBF Device C-Plus PEEK IBF Device

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

1. Is at least 21 years of age and skeletally mature.
2. Must have cervical disc disease (defined as neck pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies) at one level in the cervical spine between C3 to T1.
3. Must have completed a minimum of six weeks of unsuccessful conservative, non- operative care or has the presence of progressive symptoms or signs of nerve root/spinal cord compression in the face of conservative treatment
4. Has pre-operative objective evidence of primary diagnosis confirmed by appropriate imaging studies (AP/LAT/FLX/EXT X-rays \& a recent MRI)
5. Is willing and able to comply with all clinical investigation visits and procedures including screening treatment procedures, post-operative management, the follow-up schedule and completion of forms or questionnaires.
6. Is able to understand and sign the informed consent document

Exclusion Criteria

1. Requires fusion at more than one level
2. Has had prior fusion at the level to be treated.
3. Has a metabolic or systemic bone disorder.
4. Has a disease that significantly inhibits bone healing (i.e., severe osteoporosis, osteomalacia, Paget's disease)
5. Has a systemic or local infection (active or latent)
6. Has acute or chronic infections in the surgical area (i.e., soft tissue infections; inflammatory, bacterial bone disorders, osteomyelitis)
7. chronic use of steroids, other than episodic use or inhaled corticosteroids
8. has any significant general illness (i.e. tested positive for HIV, Hepatitis B or Hepatitis C, has active metastatic cancer of any type, uncontrolled diabetes Type I, dialysis dependent renal failure, symptomatic liver disease)
9. has a mental or physical condition that would limit the ability to comply with study requirements or would preclude accurate evaluation.
10. Is immunocompromised or being treated with immunosuppressive agents (including chemotherapy or radiation treatment).
11. has documented allergies to hydroxyapatite or porcine collagen, PEEK, titanium, titanium alloy or tantalum.
12. currently pregnant, or interested in becoming pregnant during the clinical investigation follow-up
13. is a smoker
14. is a prisoner
15. is currently involved in another drug or device clinical investigation that may confound the clinical investigation data.
Minimum Eligible Age

21 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

No

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

RTI Surgical

INDUSTRY

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Responsibility Role SPONSOR

Principal Investigators

Learn about the lead researchers overseeing the trial and their institutional affiliations.

Dieter Peuskens, MD

Role: PRINCIPAL_INVESTIGATOR

Ziekenhuis Oost-Limburg

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

Ziekenhuis Oost Limburg

Genk, , Belgium

Site Status

Countries

Review the countries where the study has at least one active or historical site.

Belgium

References

Explore related publications, articles, or registry entries linked to this study.

Zhao Z, Jiang D, Ou Y, Tang K, Luo X, Quan Z. A hollow cylindrical nano-hydroxyapatite/polyamide composite strut for cervical reconstruction after cervical corpectomy. J Clin Neurosci. 2012 Apr;19(4):536-40. doi: 10.1016/j.jocn.2011.05.043. Epub 2012 Feb 3.

Reference Type BACKGROUND
PMID: 22305868 (View on PubMed)

Kim SC, Kang SW, Kim SH, Cho KH, Kim SH. Clinical and radiological outcomes of anterior cervical interbody fusion using hydroxyapatite spacer. J Korean Neurosurg Soc. 2009 Oct;46(4):300-4. doi: 10.3340/jkns.2009.46.4.300. Epub 2009 Oct 31.

Reference Type BACKGROUND
PMID: 19893716 (View on PubMed)

Ryken TC, Heary RF, Matz PG, Anderson PA, Groff MW, Holly LT, Kaiser MG, Mummaneni PV, Choudhri TF, Vresilovic EJ, Resnick DK; Joint Section on Disorders of the Spine and Peripheral Nerves of the American Association of Neurological Surgeons and Congress of Neurological Surgeons. Techniques for cervical interbody grafting. J Neurosurg Spine. 2009 Aug;11(2):203-20. doi: 10.3171/2009.2.SPINE08723.

Reference Type BACKGROUND
PMID: 19769500 (View on PubMed)

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

NC03

Identifier Type: -

Identifier Source: org_study_id

More Related Trials

Additional clinical trials that may be relevant based on similarity analysis.

Allogeinic Bone Paste
NCT04605120 UNKNOWN NA
Titanium vs. PEEK Fusion Devices in 1 Level TLIF
NCT05691062 ENROLLING_BY_INVITATION PHASE4