Comparative Effectiveness of 30%TSC and Heparin Lock Solution in Hemodialysis Catheters
NCT ID: NCT02563041
Last Updated: 2015-09-29
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
COMPLETED
PHASE4
179 participants
INTERVENTIONAL
2012-07-31
2014-07-31
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Efficacy and Safety of an Ethanol/Sodium Citrate Locking Solution: A Pilot Study
NCT01394458
Taurolidine in Haemodialysis Catheter Related Bacteraemia
NCT01243710
Neutrolin Versus Heparin for Locking Hemodialysis Catheters
NCT03425448
Efficacy of Urokinase Containing Locking Solutions for Thrombotic Dysfunction of Tunneled Hemodialysis Catheters
NCT02770560
Prevention of Dialysis Catheter Malfunction With Prophylactic Use of a Taurolidine Containing Urokinase
NCT02036255
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
After each hemodialysis (HD) session, patients assigned to 30%TSC had their catheter lumens flushed with 0.9% sodium chloride and locked with a volume of 30% TSC solution equivalent to the catheter internal lumen. Patients assigned to heparin had their catheter lumens flushed with 0.9% sodium chloride and locked with a volume of 5000 U/mL heparin equivalent to CVC internal lumen. Catheter care was according to international guidelines, including strict asepsis on insertion and exit-site dressing changes after each HD session by staff wearing masks and sterile gloves.
SELECTION OF PATIENTS Patients were eligible for enrollment in the RCT when they were older than 18 years and had chronic or acute renal failure that required hemodialysis through a catheter. Patients admitted to the intensive care ward, receiving a tunneled catheter, with suspected heparin-induced thrombocytopenia, allergy to heparin or TSC30%, with systemic or localized infection or pregnant women were excluded. The site of insertion and specific type of catheter were decided by the interventionist physician.
MAIN OUTCOMES Catheter related bloodstream infection (CRBSI): CRBSI was defined as fever and/or chills during a dialysis session and at least one positive blood culture, with no other obvious cause of infection after careful clinical examination. The management of the CRBSI was performed according to guidelines. Empirical antibiotic therapy was immediately given. The catheter was removed if there was isolation of S. aureus or fungus, or there was no clinical recovery within 48 hours of antibiotic treatment.
Catheter dysfunction: Dysfunction was defined as a persistent inability to obtain a blood flow above 200 mL/min. In this situation, the catheter was removed or exchanged over guidewire.
OTHER PREDICTORS Patients-related: Data was also collected about age, gender, skin color, presence of diabetes, diagnosis of CKD or acute kidney injury, and hemodialysis vintage.
Catheter-related: Site of insertion (jugular, subclavian or femoral vein), and ordinal number of catheter in the same patient (considering only the study period).
STATISTICAL ANALYSIS Calculation of the required sample size was based on main outcomes. It was assumed that the group with heparin lock would have a rate of catheter-related bloodstream infection of 150% greater than that of catheters with TCS30% lock. With a two-sided test, and an alfa error of 5% and 80% of power, it was required 112 catheters for each group.
The primary analysis was made through survival analysis with Cox proportional hazard regression. Initially the investigators proceed to univariate analysis using Kaplan-Meier curves and log rank test for the categorical variables, and univariate Cox regression for continuous variables. The predictors which have a p-value lower than 0.25 in univariate analysis were included in final model. Interactions were checked for any possible association of predictors. The likelihood ratio test was used for compare nested with full models. The proportionality of predictors was verified by introduction of time-dependent variables in the model. If any predictor violates the proportionality assumption, the analysis would be stratified for that predictor. Well-functioning catheters at the end of the study period, catheters removed because patients acquired functional arteriovenous fistula, renal function recovery, changed to peritoneal dialysis or had transplantation were analyzed as censored data. The analysis was all done on intention-to-treat base. All reported p-value are two sided. The analysis was performed using the STATA 11.2 statistical software (Stata Corporation, College Station, TX, USA)
ETHICAL ASPECTS The study protocol was approved by the local review board. Written informed consent was obtained from all patients before enrollment.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
RANDOMIZED
PARALLEL
PREVENTION
QUADRUPLE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
30%TSC
After each hemodialysis (HD) session, the catheter lumens were flushed with 0.9% sodium chloride and locked with a volume of 30%TSC solution exactly equivalent to the catheter internal lumen.
30% TSC
The patients were randomly assigned to have their catheter locked with either unfractionated sodium heparin 5000 U/mL or 30% trisodium citrate.
Heparin 5000 U/mL
After each hemodialysis (HD) session, the catheter lumens were flushed with 0.9% sodium chloride and locked with a volume of unfractionated sodium heparin 5000 U/mL solution exactly equivalent to the catheter internal lumen.
Heparin
The patients were randomly assigned to have their catheter locked with either unfractionated sodium heparin 5000 U/mL or 30% trisodium citrate.
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
30% TSC
The patients were randomly assigned to have their catheter locked with either unfractionated sodium heparin 5000 U/mL or 30% trisodium citrate.
Heparin
The patients were randomly assigned to have their catheter locked with either unfractionated sodium heparin 5000 U/mL or 30% trisodium citrate.
Other Intervention Names
Discover alternative or legacy names that may be used to describe the listed interventions across different sources.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
* with chronic or acute renal failure and
* requiring hemodialysis through a catheter.
Exclusion Criteria
* receiving a tunneled catheter,
* patients with suspected heparin-induced thrombocytopenia,
* patients with allergy to heparin or TSC30%,
* patients with systemic or localized infection
* pregnant women
18 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Catholic University of Pelotas
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Maristela Bohlke
MD PhD
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
Maristela Bohlke, MD, PhD
Role: PRINCIPAL_INVESTIGATOR
Catholic University of Pelotas
References
Explore related publications, articles, or registry entries linked to this study.
Correa Barcellos F, Pereira Nunes B, Jorge Valle L, Lopes T, Orlando B, Scherer C, Nunes M, Araujo Duarte G, Bohlke M. Comparative effectiveness of 30 % trisodium citrate and heparin lock solution in preventing infection and dysfunction of hemodialysis catheters: a randomized controlled trial (CITRIM trial). Infection. 2017 Apr;45(2):139-145. doi: 10.1007/s15010-016-0929-4. Epub 2016 Aug 29.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
UCPel
Identifier Type: -
Identifier Source: org_study_id
More Related Trials