Lung Ultrasound Safety in Humans

NCT ID: NCT02453724

Last Updated: 2016-03-18

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

UNKNOWN

Total Enrollment

200 participants

Study Classification

OBSERVATIONAL

Study Start Date

2015-08-31

Study Completion Date

2017-08-31

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

The purpose of this study is to investigate if diagnostic ultrasound as it is routinely performed in humans causes lung hemorrhage significant enough to appear on thoracic CT. The investigators' hypothesis is that diagnostic lung ultrasound will not cause lung hemorrhage in humans. Damage to the lung in animal models has been shown to be mechanical rather than thermal in nature and evidence suggests that this injury is likely not from inertial cavitation but from alveolar resonance. Models of the alveolar resonance theory predict that hemorrhage should not happen in adult human lungs if the ultrasound frequency is higher than 1.69 MHz and mechanical index (MI) is less than 1.9 which is maintained with standard scanning protocol for thoracic ultrasound. A previous human study showed no gross macroscopic lung hemorrhage in patients undergoing transesophageal echocardiography with pressures of 2.4 MPa and MI 1.3 with exposure durations ranging 7-68 minutes.

The investigators propose to perform a routine lung ultrasound exam on patients who are scheduled to undergo chest computed tomography evaluation for pulmonary embolus as part of their routine care. The ultrasound will be performed immediately prior to CT imaging and markers will be placed on the patients chest to ensure the correct lung tissue is being evaluated. There will be two sham markers so the radiologist will be blinded to which tissue had ultrasound applied and which did not. The CT scan will then be evaluated per routine and also to see if there are signs of microscopic or macroscopic hemorrhage under the skin markers.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

This is a prospective, observational cohort study of emergency department patients designed to assess for radiographic changes suggestive of lung hemorrhage after thoracic ultrasound.

The investigators will only approach patients scheduled for CT scan as part of their routine care in the emergency department for enrollment. Only patients \> 18 years old. Patients who are not english speaking will only be consented if there is a medical interpreter immediately available who can be approached for informed consent.

Patients who have given informed consent will have a lung ultrasound performed by a study physician immediately prior to CT scan - after the patient has been transported to the ED radiology area but before the CT scan is performed. The lung ultrasound will be performed using a low frequency probe (2-5 MHz). Of the four standard positions used in lung ultrasonography (Zone 1, 4, 5, 8; see Image 1 below), study ultrasonography will be performed on only two.

The two positions selected for use will be chosen immediately prior to ultrasound performance by the performing physician using a simple binary random number generator for each lung. This will ensure that one zone is subjected to ultrasound on each lung. A small radio-opaque button will be placed overlying all four zones (i.e., those exposed and those not exposed) in the standard position of the ultrasound footprint (ie where the ultrasound was or would have been performed) and then the patient will undergo the CT scan according to standard radiology department protocols.

The CT scan will then be reviewed for signs of alveolar hemorrhage in the lung tissue immediately adjacent to the radio-opaque button. Radiologists will be blinded as to which buttons abut zones exposed to ultrasound or not exposed. Any findings will be immediately reported to the patient's care team and the patient and standard protocols for treatment and observation will be followed.

The investigators have calculated the need to enroll 200 patients to observe a 7% range above and below previously published numbers of incidental findings on chest CT scan.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Pulmonary Hemorrhage

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Observational Model Type

COHORT

Study Time Perspective

PROSPECTIVE

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

Observation for safety

The investigators will perform the routine lung exam used in emergency department evaluations for shortness of breath in patients scheduled for computed tomography. The investigators will observe if there are any parenchymal changes noted on the chest tomography scan.

Intervention Type DEVICE

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

* All patients greater than 18 years of age scheduled to receive chest tomography scans for pulmonary embolus.

Exclusion Criteria

* None.
Minimum Eligible Age

18 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

Yes

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

Massachusetts General Hospital

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Vicki Noble, MD

Director, Division of Emergency Ultrasound

Responsibility Role PRINCIPAL_INVESTIGATOR

Principal Investigators

Learn about the lead researchers overseeing the trial and their institutional affiliations.

Vicki E Noble, MD

Role: PRINCIPAL_INVESTIGATOR

Massachusetts General Hospital

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

Massachusetts General Hospital

Boston, Massachusetts, United States

Site Status RECRUITING

Countries

Review the countries where the study has at least one active or historical site.

United States

Central Contacts

Reach out to these primary contacts for questions about participation or study logistics.

Vicki E Noble, MD

Role: CONTACT

617-726-5655

John T Nagurney, MD

Role: CONTACT

617-726-7623

Facility Contacts

Find local site contact details for specific facilities participating in the trial.

Vicki Noble, MD

Role: primary

617-726-5655

References

Explore related publications, articles, or registry entries linked to this study.

O'Brien WD Jr, Yang Y, Simpson DG, Frizzell LA, Miller RJ, Blue JP Jr, Zachary JF. Threshold estimation of ultrasound-induced lung hemorrhage in adult rabbits and comparison of thresholds in mice, rats, rabbits and pigs. Ultrasound Med Biol. 2006 Nov;32(11):1793-804. doi: 10.1016/j.ultrasmedbio.2006.03.011.

Reference Type BACKGROUND
PMID: 17112965 (View on PubMed)

Miller DL. Induction of pulmonary hemorrhage in rats during diagnostic ultrasound. Ultrasound Med Biol. 2012 Aug;38(8):1476-82. doi: 10.1016/j.ultrasmedbio.2012.04.004. Epub 2012 Jun 12.

Reference Type BACKGROUND
PMID: 22698500 (View on PubMed)

Jabaraj DJ, Jaafar MS. Theoretical calculation of resonant frequencies of the human alveolar wall and its implications in ultrasound-induced lung hemorrhage. Int J Bioscience Biochem Bioinformatics. 2013;3(1):5-9

Reference Type BACKGROUND

Meltzer RS, Adsumelli R, Risher WH, Hicks GL Jr, Stern DH, Shah PM, Wojtczak JA, Lustik SJ, Gayeski TE, Shapiro JR, Carstensen EL. Lack of lung hemorrhage in humans after intraoperative transesophageal echocardiography with ultrasound exposure conditions similar to those causing lung hemorrhage in laboratory animals. J Am Soc Echocardiogr. 1998 Jan;11(1):57-60. doi: 10.1016/s0894-7317(98)70120-8.

Reference Type BACKGROUND
PMID: 9487470 (View on PubMed)

Bruzzi JF, Remy-Jardin M, Delhaye D, Teisseire A, Khalil C, Remy J. Multi-detector row CT of hemoptysis. Radiographics. 2006 Jan-Feb;26(1):3-22. doi: 10.1148/rg.261045726.

Reference Type BACKGROUND
PMID: 16418239 (View on PubMed)

Child SZ, Hartman CL, Schery LA, Carstensen EL. Lung damage from exposure to pulsed ultrasound. Ultrasound Med Biol. 1990;16(8):817-25. doi: 10.1016/0301-5629(90)90046-f.

Reference Type RESULT
PMID: 2095012 (View on PubMed)

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

2013P002671

Identifier Type: -

Identifier Source: org_study_id

More Related Trials

Additional clinical trials that may be relevant based on similarity analysis.