Study Results
Outcome measurements, participant flow, baseline characteristics, and adverse events have been published for this study.
View full resultsBasic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
COMPLETED
NA
24 participants
INTERVENTIONAL
2015-04-30
2015-09-30
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
To evaluate the accuracy and performance of the new generation Enlite sensor. This is a postmarket, interventional, open-label, non-randomized, single center clinical research trial.
The trial will adopt a prospective single-sample design using the Yellow Spring Instruments (YSI) plasma glucose reference sampling procedure in the clinic and self-monitoring of blood glucose (SMBG) plasma glucose reference sampling procedure at home.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Evaluation of the Accuracy of an Implanted Glucose Sensor
NCT02647905
Standardized Procedure for the Assessment of New-to-market Continuous Glucose Monitoring Systems
NCT01751932
Comparison Between Enlite and Flash Glucose Monitoring
NCT03249974
PRECISE: A Prospective, Multi-Center Evaluation of the Accuracy of a Novel Continuous Implanted Glucose Sensor
NCT02154126
Feasibility Study to Assess the Safety and Functionality of the GluSense Continuous Glucose Monitor in Diabetic Patients
NCT01198678
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
The current trial investigates the accuracy of the new sensor in conjunction with the new 640G system components both in the clinic and at home. This enables us to assess the sensor accuracy in a well-controlled environment using a highly accurate laboratory glucose analyzer as reference as well as sensor accuracy during real-life conditions using a blood glucose meter as reference analyzer.
The data gathered in this trial will help to understand the effect of technological advancements made and can guide future development of glucose sensor for continuous glucose monitoring.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
NA
SINGLE_GROUP
TREATMENT
NONE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
Open-label, single-sample design
The trial has an open label design with a glucose sensor intervention. Only 1 sensor system is used in the trial (no comparator).
As all subjects will receive identical devices and undergo the same experimental procedures, no randomization will be performed. Furthermore, neither subjects nor clinical staff will be blinded to the sensor readings, as knowing the sensor glucose readings will not affect the accuracy endpoint.
Glucose sensor (Enlite)
This is a postmarket, interventional, open-label, non-randomized, single center clinical research trial. The trial will adopt a prospective single-sample design using the Yellow Spring Instruments (YSI) plasma glucose reference sampling procedure in the clinic and selfmonitoring of blood glucose (SMBG) plasma glucose reference sampling procedure at home. The trial will consist of 6 visits to the investigational site: a visit for informed consent procedures (Visit 0), a screening visit (Visit 1), 3 study visits (Visit 2-4) and a final examination (Visit 5).
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
Glucose sensor (Enlite)
This is a postmarket, interventional, open-label, non-randomized, single center clinical research trial. The trial will adopt a prospective single-sample design using the Yellow Spring Instruments (YSI) plasma glucose reference sampling procedure in the clinic and selfmonitoring of blood glucose (SMBG) plasma glucose reference sampling procedure at home. The trial will consist of 6 visits to the investigational site: a visit for informed consent procedures (Visit 0), a screening visit (Visit 1), 3 study visits (Visit 2-4) and a final examination (Visit 5).
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
* Age 18-74 years (both inclusive)
* Subject has been diagnosed with T1DM
* Subject is current insulin pump user for at least 3 months
* HbA1c 9.5%
* With the exception of T1DM, the subject is considered generally healthy upon completion of medical history, physical examination, vital signs, ECG and biochemical investigations as judged by the Investigator
Exclusion Criteria
* Subject has any condition that, in the opinion of the Investigator or qualified Investigational Centre staff, may preclude him/her from participating in the study and completing study related procedures.
* Subject has impaired vision or hearing problems that could compromise the handling of the device as determined by Investigator or qualified Investigational Centre staff
* Subject is unable to tolerate tape adhesive in the area of sensor placement
* Subject has any unresolved adverse skin condition in the area of sensor placement (e.g. psoriasis, rash, Staphylococcus infection)
* Subject has travel plans which would make it difficult for the subject to attend on-site study visits as scheduled
* Subject is actively participating in an investigational study (drug or device) wherein he/she has received treatment from an investigational study drug or investigational study device in the last 30 days
* Subject known to be positive for Hepatitis B surface antigen (HBsAg) or Hepatitis C antibodies (or diagnosed with active hepatitis according to local practice).
* Positive result to the screening test for HIV-1 antibodies, HIV-2 antibodies or HIV-1 antigen according to locally used diagnostic testing
* Significant history of alcoholism or drug/chemical abuse as per investigator's judgment, current regular alcohol consumption of more than 1 unit per day for women and more than 2 units per day for men \[1 unit of alcohol equals 1 beer (330 mL), 1 glass of wine (120 mL), or 1 glass of spirits (40 mL)\], or a positive result in the urine drug/alcohol screen at the screening visit
18 Years
74 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Profil Institut für Stoffwechselforschung GmbH
INDUSTRY
Medtronic Diabetes
INDUSTRY
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
CEP 296
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.