Study Results
Outcome measurements, participant flow, baseline characteristics, and adverse events have been published for this study.
View full resultsBasic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
COMPLETED
472 participants
OBSERVATIONAL
2016-06-06
2017-06-20
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
The Effects of RT-CGM on Glycemia and QoL in Patients With T1DM and IHA
NCT01787903
Effect of Continuous Glucose Monitoring on Course of Glucose in Type 1 Diabetes
NCT00467688
Continuous Glucose Monitoring in Type 2 Diabetes Mellitus
NCT01083043
Accuracy of Two CGM Systems Tested Simultaneously in Ambulatory Patients With Type 1 Diabetes
NCT02159638
Standardized Procedure for the Assessment of New-to-market Continuous Glucose Monitoring Systems
NCT01751932
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
Continuous Glucose Monitoring (CGM) provides an interstitial glucose reading every 5 minutes and is thus a powerful and important tool to identify glycaemic variability in people with diabetes. CGM is valuable for people with diabetes to understand their glucose metabolism and it has the potential to be used for detection and prediction of glycaemic excursions, such as, the potentially fatal and inevitable events of hypoglycaemia, or even as a component in the holy grail of diabetes technology; the artificial pancreas.
However, CGM has been criticised for being inaccurate and unreliable, amongst others, due to the physiological and a device-related delay between plasma glucose (PG) and interstitial glucose (IG). Nevertheless, CGM keeps on being popular and in February 2017 an international consensus was established at the Advanced Technologies \& Treatments for Diabetes (ATTD) congress that even considers CGM data as a valuable and meaningful end point to be used in clinical trials of new drugs and devices for diabetes treatment where accuracy is of high importance.
The above mentioned use cases entail that the CGM data are accurate. Therefore, the first part of this research proposal is to investigate whether the newest state-of-the-art CGM devices used in Novo Nordisk trials are in fact accurate. Based on these results, it is investigated to which degree glycaemic variability can be revealed.
To investigate the accuracy of CGM, mean absolute relative difference (MARD) will be calculated and presented and the impact of the delay assessed by time shifting CGM measurements. Furthermore, correlation analyses, between for example, PG and first derivative of IG, will be performed to try to understand when CGM devices tend to measure inaccurate. Lastly, machine learning and/or deep learning approaches will be utilised to reveal glycaemic patterns and to detect/predict outcomes, such as, hypoglycaemia.
Different glycaemic variability investigations will be undertaken:
* Test of PG vs IG and effect on clinical research. \[analysis of differences\]
* Correlation between PG values at bedtime and nocturnal hypoglycaemic events \[correlation analyses\]
* Effect of main evening meal and meal-time dose on nocturnal hypoglycaemic events \[correlation analyses\]
* Prediction of PG-confirmed hypoglycaemic events with CGM, dose and meal data as input \[machine learning\]
* The optimal dose and meal distribution and least CGM variability / eHbA1c \[machine learning\]
* Algorithm to suggest optimal dosing in relation to glycaemic variability \[machine learning\]
Requested data are demographic, CGM, meal, dose and hypoglycaemia data from the following trial. The analyses are independent of treatment and therefore the treatment arm can be blinded.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
OTHER
RETROSPECTIVE
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
CGM
This study seeks to assess CGM accuracy and develop prediction models for hypoglycemia detection and no intervention is therefore applied.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
* Diagnosed with T1DM (Type 1 Diabetes Mellitus) (based on clinical judgement and/or supported by laboratory analysis as per local guidelines) equal or above 1 year prior to the day of screening
* Using the same Medtronic pump (Minimed 530G (551/751), Paradigm Veo (554/754), Paradigm Revel (523/723), Paradigm (522/722)) for CSII in a basal-bolus regimen with a rapid acting insulin analogue for at least six months prior to screening and willing to stay on the same pump model throughout the trial (if the model is changed the change should not exceed 7 consecutive days.)
* HbA1c (glycosylated haemoglobin) 7.0-9.0% (53-75 mmol/mol) as assessed by central laboratory at screening
* Body mass index (BMI) below or equal to 35.0 kg/m\^2 at screening
* Ability and willingness to take at least 3 daily meal-time insulin bolus infusions every day throughout the trial
* Any condition which, in the opinion of the Investigator, might jeopardise a Subject's safety or compliance with the protocol
Exclusion Criteria
* Planned coronary, carotid or peripheral artery revascularisation known on the day of screening
* History of hospitalization for ketoacidosis below or equal to 180 days prior to the day of screening
18 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Peter Vestergaard
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Peter Vestergaard
Professor
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
Peter Vestergaard, PhD
Role: PRINCIPAL_INVESTIGATOR
Steno Diabetes Center North Denmark
References
Explore related publications, articles, or registry entries linked to this study.
Rodbard D. Continuous Glucose Monitoring: A Review of Recent Studies Demonstrating Improved Glycemic Outcomes. Diabetes Technol Ther. 2017 Jun;19(S3):S25-S37. doi: 10.1089/dia.2017.0035.
Jensen MH, Christensen TF, Tarnow L, Seto E, Dencker Johansen M, Hejlesen OK. Real-time hypoglycemia detection from continuous glucose monitoring data of subjects with type 1 diabetes. Diabetes Technol Ther. 2013 Jul;15(7):538-43. doi: 10.1089/dia.2013.0069. Epub 2013 Apr 30.
Jensen MH, Christensen TF, Tarnow L, Mahmoudi Z, Johansen MD, Hejlesen OK. Professional continuous glucose monitoring in subjects with type 1 diabetes: retrospective hypoglycemia detection. J Diabetes Sci Technol. 2013 Jan 1;7(1):135-43. doi: 10.1177/193229681300700116.
El-Khatib FH, Balliro C, Hillard MA, Magyar KL, Ekhlaspour L, Sinha M, Mondesir D, Esmaeili A, Hartigan C, Thompson MJ, Malkani S, Lock JP, Harlan DM, Clinton P, Frank E, Wilson DM, DeSalvo D, Norlander L, Ly T, Buckingham BA, Diner J, Dezube M, Young LA, Goley A, Kirkman MS, Buse JB, Zheng H, Selagamsetty RR, Damiano ER, Russell SJ. Home use of a bihormonal bionic pancreas versus insulin pump therapy in adults with type 1 diabetes: a multicentre randomised crossover trial. Lancet. 2017 Jan 28;389(10067):369-380. doi: 10.1016/S0140-6736(16)32567-3. Epub 2016 Dec 20.
Rebrin K, Sheppard NF Jr, Steil GM. Use of subcutaneous interstitial fluid glucose to estimate blood glucose: revisiting delay and sensor offset. J Diabetes Sci Technol. 2010 Sep 1;4(5):1087-98. doi: 10.1177/193229681000400507.
Kovatchev BP, Patek SD, Ortiz EA, Breton MD. Assessing sensor accuracy for non-adjunct use of continuous glucose monitoring. Diabetes Technol Ther. 2015 Mar;17(3):177-86. doi: 10.1089/dia.2014.0272. Epub 2014 Dec 1.
Danne T, Nimri R, Battelino T, Bergenstal RM, Close KL, DeVries JH, Garg S, Heinemann L, Hirsch I, Amiel SA, Beck R, Bosi E, Buckingham B, Cobelli C, Dassau E, Doyle FJ 3rd, Heller S, Hovorka R, Jia W, Jones T, Kordonouri O, Kovatchev B, Kowalski A, Laffel L, Maahs D, Murphy HR, Norgaard K, Parkin CG, Renard E, Saboo B, Scharf M, Tamborlane WV, Weinzimer SA, Phillip M. International Consensus on Use of Continuous Glucose Monitoring. Diabetes Care. 2017 Dec;40(12):1631-1640. doi: 10.2337/dc17-1600.
Provided Documents
Download supplemental materials such as informed consent forms, study protocols, or participant manuals.
Document Type: Study Protocol
Document Type: Statistical Analysis Plan
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
sdcn1802
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.