Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
ACTIVE_NOT_RECRUITING
NA
411 participants
INTERVENTIONAL
2015-03-31
2025-09-30
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
The AWARE study will compare two techniques of AF catheter ablation:
1. Ablation of tissues in wide circular bands around the opening of the pulmonary veins (bring blood back from lungs) in the left upper chamber of the heart. A medicine called adenosine will be given to unmask any incompletely ablated area. Additional ablations will be given if required. This is standard procedure.
2. Same as above but adenosine will not be used. Instead, additional ablation of a second circular band of tissues around the opening of the pulmonary veins will be given. This additional ablation is not standard procedure and is considered experimental.
The Investigators are testing if adding more ablation sites will help maintain normal heart rhythm and reduce the rate of return to AF. The study will compare the occurrence of medical events and complications between the two groups.
Identical supplies and equipment used in both techniques have been approved by Health Canada. Adenosine is currently approved by Health Canada for the treatment and diagnosis of arrhythmias.
396 participants from study sites across Canada will be randomly assigned "similar to flipping a coin" to treatment group 1 or group 2.
After the ablation, participants will have study follow-up at 3, 6 and 12 months. All participant's will be followed for a minimum of 12 months.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Randomized Controlled Trial- Ablation Strategy for Paroxysmal Atrial Fibrillation - Trigger and Substrate Guided Wide Area Radiofrequency Ablation Compared to Pulsed Field Ablation Pulmonary Vein Isolation
NCT04823299
Wearable Cardiac Monitor to Enhance Detection of Arrhythmia Recurrence After Catheter Ablation of Atrial Fibrillation
NCT06564012
A Trial of High Power-Short Duration Versus Standard Power-Long Duration Radiofrequency Ablation for Treatment of Atrial Fibrillation
NCT04148664
Atrial Fibrillation Ablation Pilot Study
NCT00744835
The Impact of "First-Line" Rhythm Therapy on AF Progression
NCT05514860
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
The problem of PV reconnection and recurrent AF after catheter ablation for paroxysmal AF is one of the important challenges faced by treating physicians.
Rationale:
The understanding of the role contact force plays in adequate lesion formation during catheter ablation and the fact that this may reduce pulmonary vein (PV) reconnection and AF recurrence is an exciting advance in the field of catheter ablation for AF. A few small clinical trials have demonstrated the safety and feasibility of contact force guided catheter ablation in reducing PV reconnection and AF recurrence. There is a clear need for well designed and adequately powered clinical trials to evaluate the effectiveness of this new strategy. The investigators have developed a novel "augmented" CF guided augmented ablation strategy and will test this against the current clinical gold standard ablation technique.
Objective:
Using contact force (CF) technology, our intention is to evaluate an "augmented- wide area circumferential catheter ablation strategy" that could potentially reduce the incidence of pulmonary vein reconnection and AF recurrence after catheter ablation in patients with paroxysmal AF.
Hypothesis:
In patients with symptomatic paroxysmal AF an augmented-wide area circumferential catheter ablation strategy will result in fewer electrocardiographically documented atrial arrhythmias (AF, atrial flutter and atrial tachycardia) recurrences compared to conventional wide-area catheter ablation.
All subjects in the control arm of the trial will undergo wide area circumferential catheter ablation (WACA; lesions delivered 1-2 cm away from the pulmonary vein ostium) around all four pulmonary veins to the endpoint of electrical isolation (demonstrated by entry and exit block using differential pacing). Catheter ablation will be performed using CF and VISITAG guidance (average CF \>10g, Force time integral (FTI) \> 500 g-sec and minimum ablation duration \>10 sec). Dormant PV conduction will be tested using adenosine, after completion of the lesion set, and additional lesions will be delivered to eliminate dormant PV conduction.
In the experimental arm of the trial all subjects will undergo WACA as described above; however without adenosine testing. In addition these subjects will receive "augmented" ablation lesions, guided by CF feedback, on the outer aspect of the first WACA lesion set. Our hypothesis is that this "belts and suspender" strategy of redundant, CF guided antral ablation lesions will result in a wider band of irreversible atrial muscle and cardiac autonomic ganglionated-plexi damage. It is our expectation that the augmented WACA strategy will result in more durable PV isolation and thereby significantly reduce AF recurrence.
Trial Design:
This trial is a multicentre, prospective, randomized, blinded endpoint trial (PROBE) design. Subjects who satisfy the inclusion and exclusion criteria will be enrolled in the clinical trial. Subjects will be randomized (1:1) to either the control arm (WACA only) or the experimental arm (augmented- WACA). Patients randomized to the experimental arm will go on to have augmented-WACA. The first 90 days after catheter ablation will be considered a "blanking-period" and atrial tachyarrhythmias (AF, Atrial Flutter \[AFl\] or Atrial Tachycardia \[AT\]) occurring during this period will be documented. However, these will not be considered treatment failures. Patient accrual will occur over a 24-month period and each subject will have a minimum follow-up period of 12 months. The total duration of the trial will be 36-months (24 months for accrual and a minimum of 12 months of follow up for each subject). Patients will be followed at 3, 6, and 12 months, with 14 day continuous ambulatory ECG monitoring done at each follow up visit. A total of three questionnaires will be administered throughout the study, each at a specific time point. The Quality of Life (EQ-5D) and CCS-Severity of AF scale will be completed together, prior to ablation and at the final follow-up visit. The patient satisfaction score will be completed at the final follow-up visit. All participants will be followed for a minimum of 12 months.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
RANDOMIZED
PARALLEL
TREATMENT
SINGLE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
Augmented- WACA
Augmented- wide area circumferential catheter ablation for atrial fibrillation
Augmented- wide area circumferential ablation procedure
Subjects in this group will have WACA performed as described for WACA. Following completion of the WACA procedure a second set of circumferential ablation lesions will be delivered around the first set of ablation lesions. The ablation catheter tip will be positioned at each of the ablation lesions along the first WACA line and then moved away (from the PV ostia) until healthy, non ablated tissue is recorded from the catheter tip. Energy will be delivered using CF and FTI data as described previously. Once the first WACA ablation line has been completely duplicated the procedure will be deemed complete. In case PV isolation is not achieved after the first WACA lesion set repeat electrophysiologic testing will be performed to determine whether the augmented-WACA procedure was successful in achieving PV isolation.
WACA
Wide area circumferential catheter ablation procedure for atrial fibrillation
Wide area circumferential catheter ablation
All subjects in the control arm of the trial will undergo wide area circumferential catheter ablation (WACA; lesions delivered 1-2 cm away from the pulmonary vein ostium) around all four pulmonary veins to the endpoint of electrical isolation (demonstrated by entry and exit block using differential pacing). Catheter ablation will be performed using contact force (CF) and electroanatomical mapping system guidance (average CF \>10g, FTI \> 500 g-sec and minimum ablation duration \>10 sec). Dormant pulmonary vein conduction will be tested using adenosine, after completion of the lesion set, and additional lesions will be delivered to eliminate dormant PV conduction.
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
Wide area circumferential catheter ablation
All subjects in the control arm of the trial will undergo wide area circumferential catheter ablation (WACA; lesions delivered 1-2 cm away from the pulmonary vein ostium) around all four pulmonary veins to the endpoint of electrical isolation (demonstrated by entry and exit block using differential pacing). Catheter ablation will be performed using contact force (CF) and electroanatomical mapping system guidance (average CF \>10g, FTI \> 500 g-sec and minimum ablation duration \>10 sec). Dormant pulmonary vein conduction will be tested using adenosine, after completion of the lesion set, and additional lesions will be delivered to eliminate dormant PV conduction.
Augmented- wide area circumferential ablation procedure
Subjects in this group will have WACA performed as described for WACA. Following completion of the WACA procedure a second set of circumferential ablation lesions will be delivered around the first set of ablation lesions. The ablation catheter tip will be positioned at each of the ablation lesions along the first WACA line and then moved away (from the PV ostia) until healthy, non ablated tissue is recorded from the catheter tip. Energy will be delivered using CF and FTI data as described previously. Once the first WACA ablation line has been completely duplicated the procedure will be deemed complete. In case PV isolation is not achieved after the first WACA lesion set repeat electrophysiologic testing will be performed to determine whether the augmented-WACA procedure was successful in achieving PV isolation.
Other Intervention Names
Discover alternative or legacy names that may be used to describe the listed interventions across different sources.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
2. Subjects must have symptomatic Paroxysmal AF that is refractory to at least one class I or Class III antiarrhythmic medication OR be intolerant of antiarrhythmic medications OR prefer not to trial antiarrhythmic medications
3. At least one episode of AF documented on 12-lead ECG, Holter monitor or Loop recorder.
4. Subjects must be able to provide informed consent
Exclusion Criteria
2. History of previous catheter or surgical ablation for AF
3. Presence of known intracardiac thrombus
4. Subjects with contraindication to systemic oral anticoagulation therapy, including a history of Heparin Induced Thrombocytopenia
5. Subjects with reversible causes of AF
6. Subjects with significant valve disease (moderate or severe mitral/aortic stenosis or regurgitation)
7. Subjects with known adverse reaction to adenosine
8. Subjects with congenital heart disease
9. Subjects that are pregnant
18 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Ottawa Heart Institute Research Corporation
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
Girish Nair, MD
Role: PRINCIPAL_INVESTIGATOR
Ottawa Heart Institute Research Corporation
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
University of Calgary-Foothills Campus
Calgary, Alberta, Canada
Victoria Cardiac Arrhythmia Trials Inc.
Victoria, British Columbia, Canada
QE II Health Sciences Centre
Halifax, Nova Scotia, Canada
University of Ottawa Heart Institute
Ottawa, Ontario, Canada
St. Michael"s Hospital
Toronto, Ontario, Canada
Toronto General Hospital-University Health Network
Toronto, Ontario, Canada
Sunnybrook Health Sciences Centre
Toronto, Ontario, Canada
McGill University Health Center
Montreal, Quebec, Canada
CIUSSSNIM-Hopital du Sacre-Coeur de Montreal
Montreal, Quebec, Canada
Institut universitaire de cardiologie et de pneumologie de Quebec
Québec, Quebec, Canada
Centre hospitalier universitaire de Sherbrooke (CHUS)
Sherbrooke, Quebec, Canada
Countries
Review the countries where the study has at least one active or historical site.
References
Explore related publications, articles, or registry entries linked to this study.
Nair GM, Birnie DH, Nery PB, Redpath CJ, Sarrazin JF, Roux JF, Parkash R, Bernier M, Sterns LD, Sapp J, Novak P, Veenhuyzen G, Morillo CA, Singh SM, Sadek MM, Golian M, Klein A, Sturmer M, Chauhan VS, Angaran P, Green MS, Bernick J, Wells GA, Essebag V. Standard vs Augmented Ablation of Paroxysmal Atrial Fibrillation for Reduction of Atrial Fibrillation Recurrence: The AWARE Randomized Clinical Trial. JAMA Cardiol. 2023 May 1;8(5):475-483. doi: 10.1001/jamacardio.2023.0212.
Nair GM, Birnie DH, Wells GA, Nery PB, Redpath CJ, Sarrazin JF, Roux JF, Parkash R, Bernier M, Sterns LD, Novak P, Veenhuyzen G, Morillo CA, Singh SM, Sturmer M, Chauhan VS, Angaran P, Essebag V. Augmented wide area circumferential catheter ablation for reduction of atrial fibrillation recurrence (AWARE) trial: Design and rationale. Am Heart J. 2022 Jun;248:1-12. doi: 10.1016/j.ahj.2022.02.009. Epub 2022 Feb 24.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
201610PJT-376677
Identifier Type: OTHER_GRANT
Identifier Source: secondary_id
IRIS 2771
Identifier Type: -
Identifier Source: org_study_id