Study Results
Outcome measurements, participant flow, baseline characteristics, and adverse events have been published for this study.
View full resultsBasic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
COMPLETED
NA
15 participants
INTERVENTIONAL
2013-04-30
2013-12-31
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Besides medical treatment, physiotherapy plays a major role in treatment and various methods have been suggested to remove airway of secretions. The flutter is a simple and small device shaped like a pipe that creates a positive expiratory pressure (PEP) and high frequency oscillation when the expired air passes through it. These vibrations are thought to mobilise airway secretions facilitating their clearance and improving breathing.
Standard blowing tests, like spirometry, where patients blow forcedly into a machine, have previously been used to investigate the efficacy of flutter devices. However, spirometry assesses the damage of larger airways but not small airways, also known as the "silent zone" which, crucially, are specifically damaged in COPD.
In this study the investigators hypothesise that because the flutter helps clear the airways from the excessive thick mucus produced by COPD patients, these patients may find it easier to breathe and have lower resistance to moving air in and out of their lungs.
The main objective of this study is to compare the effect of a flutter or a sham device on small airways damage using impulse oscillometry (IOS), a non-invasive method that, contrary to other common blowing tests, measures small airway resistance during normal breathing.
In addition, because COPD is characterised by inflammation, the investigators would also like to measure a gas the patients blow out, nitric oxide (NO) the levels of which reflect airway inflammation. This will give to investigators an insight into the relationship between airway inflammation and small airway function.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Acute Effects of a Flutter Device and Chest Wall Compression on Respiratory System Impedance in Bronchiectasis Patients
NCT02509637
The Effect of Treatment of Emphysema With Endobronchial Valves on the Diaphragm Mobility
NCT06163131
Intermittent Intrapulmonary Deflation and Dyspnea Following Exercise in People With Chronic Obstructive Pulmonary Disease
NCT06956742
Resistance Training in Patients With Chronic Obstructive Lung Disease (COPD): Whole Body Vibration Versus Conventional Resistance Training
NCT01135966
A Feasibility RCT of Aerobika Verses ACBT in People With COPD
NCT05548036
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
Patients suffering from COPD may show pathologic changes not only in the large but also in the small airways, which are defined as less than 2mm in diameter. Airway inflammation may cause increased thick mucus secretions which can narrow the airways increasing the resistance to the airflow.
Physiotherapy to remove secretions is indicated for patients with COPD who have regular sputum or those with thick secretions and various techniques and physiotherapy devices can be applied for the removal of secretions. The flutter is a simple and small device shaped like a pipe that creates a positive expiratory pressure (PEP) and high frequency oscillation as expired air passes through it. These vibrations and PEP are thought to mobilise airway secretions facilitating their clearance and improving airflow.
The effects of the flutter device have been studied in different patient groups, but especially in lung diseases characterised by mucus hypersecretion such as COPD, cystic fibrosis and bronchiectasis. In COPD, even though the flutter device increases the volume of expectorated secretions, its beneficial effects on pulmonary function as assessed by spirometry and plethysmography are inconclusive. However, these standard lung function tests (such as spirometry) asses the large airways, but do not provide an accurate estimate of the small airways which have been described by some authors as "the silent zone".
The investigators hypothesise that the use of impulse oscillometry (IOS), a non-invasive technique that provides information on small airway resistance during normal breathing, may reveal the effect of the flutter device which may have not been accurately measured by spirometry in previous studies.
In addition, the investigators would like to measure exhaled nitric oxide (NO) levels which reflect airway inflammation and may therefore be useful to determine the association between small airway disease and inflammation.
In summary, the symptoms of patients with COPD improve following breathing exercises with a flutter device, however, the effect of this device on lung function is unclear. The investigators hypothesise that the combined use IOS and NO, would help understand and quantify the effects of the flutter device on the small airways disease in COPD.
The main objective of this study is to measure the effect of a 30 minutes breathing exercise with a flutter device on airway resistance as assessed by impulse oscillometry in patients with COPD.
The secondary objective is to investigate the association between inflammation, airway resistance and volume of secretions in COPD patients.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
RANDOMIZED
CROSSOVER
TREATMENT
NONE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
flutter valve exercises
30 minutes of breathing exercises with flutter device
Flutter valve exercises
30 minutes of flutter exercises
Flutter and bronchodilator exercises
Flutter + bronchodilator exercises with an interval of 3 to 5 days
flutter-sham exercises
30 minutes of breathing exercise with flutter-sham device
Flutter Sham exercises
30 minutes of flutter-sham exercises
Flutter and bronchodilator exercises
Flutter + bronchodilator exercises with an interval of 3 to 5 days
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
Flutter valve exercises
30 minutes of flutter exercises
Flutter Sham exercises
30 minutes of flutter-sham exercises
Flutter and bronchodilator exercises
Flutter + bronchodilator exercises with an interval of 3 to 5 days
Other Intervention Names
Discover alternative or legacy names that may be used to describe the listed interventions across different sources.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
The severity of COPD will be classified according to GOLD criteria:
Stage I: mild FEV1/FVC\<0.70 and FEV1\>80% predicted; Stage II: moderate FEV1/FVC\<0.70 and 50\<FEV1\<80% predicted; Stage III: severe FEV1/FVC\<0.70 and 30\<FEV1\<50% predicted; Stage IV: very severe FEV1/FVC\<0.70 and FEV1\<30% or FEV1\<50% predicted plus chronic respiratory failure,
Exclusion Criteria
* Upper respiratory tract infection within the previous 28 days
* Treatment with antibiotics within 4 weeks prior the study
* Acute dyspnoea or hemoptysis
* Chest pain or recent history of rib fracture or pneumothorax
* Acute cardiovascular events in the previous 3 months
* Any history or evidence of renal, gastrointestinal or hepatic disease
* Any history and evidence of neuropsychiatric disease
* Alcohol, drug abuse or any other condition associated with poor compliance
* Breast feeding
* Pregnancy
* Other complications that hinder the completion of the tests
* Unable to provide written informed consent
21 Years
90 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Imperial College London
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
Omar Usmani, MD
Role: PRINCIPAL_INVESTIGATOR
Imperial College London
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Asthma Lab, Royal Brompton Hospital, National Heart and Lung Institute, Imperial College London
London, , United Kingdom
Countries
Review the countries where the study has at least one active or historical site.
References
Explore related publications, articles, or registry entries linked to this study.
Gastaldi AC, Paredi P, Talwar A, Meah S, Barnes PJ, Usmani OS. Oscillating Positive Expiratory Pressure on Respiratory Resistance in Chronic Obstructive Pulmonary Disease With a Small Amount of Secretion: A Randomized Clinical Trial. Medicine (Baltimore). 2015 Oct;94(42):e1845. doi: 10.1097/MD.0000000000001845.
Related Links
Access external resources that provide additional context or updates about the study.
Gastaldi AC, et al. Oscillating Positive Expiratory Pressure on Respiratory Resistance in Chronic Obstructive Pulmonary Disease With a Small Amount of Secretion: A Randomized Clinical Trial. Medicine (Baltimore) 2015; 94(42): 1-8.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
13/C0346
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.