BES, EES, and ZES-R in Real World Practice

NCT ID: NCT01397175

Last Updated: 2019-07-09

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

TERMINATED

Clinical Phase

NA

Total Enrollment

1960 participants

Study Classification

INTERVENTIONAL

Study Start Date

2013-01-16

Study Completion Date

2019-01-01

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

The primary objective of this study is to compare the rate of device-oriented composite consisted of cardiac death, myocardial infarction not clearly attributable to a nontarget vessel, and clinically indicated target lesion revascularization among the patients treated with EES, ZES-R, or BES at 24-month clinical follow-up post-index procedure. Trial end points are summarized in Table I. The hypothesis is that BES is equivalent to EES or BES is equivalent to ZES-R at the primary end point.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

Previous randomized trials have shown the superior efficacy of drug-eluting stents (DES), such as sirolimus-eluting stent (SES, CYPHER, Cordis, US), paclitaxel-eluting stent (PES, TAXUS, Boston Scientific, US), and zotarolimus-eluting stent (ZES, Endeavor, Medtronic, US) compared with bare metal stents (BMS) by reducing neointimal hyperplasia, late luminal loss, and angiographic restenosis leading to decreased target lesion revascularization. Unfortunately, restenosis still occurs and late stent thrombosis can develop by delaying endoluminal healing or by chronic inflammation.Accordingly, development of new DES is required to improve efficacy by reducing revascularization and safety by reducing the risk of stent thrombosis. With the improvement of polymer, drug, and the platform, the 2nd generation DES, including everolimus-eluting stent (EES, Xience V or Xience Prime, Abbott, USA), zotarolimus-eluting stent with biolinx polymer (ZES-R, Endeavor Resolute or Endeavor Resolute Integrity, Medtronic, USA), and biolimus-eluting stent (BES, BioMatrix or Biomatrix Flex, Biosensors, USA), have been shown to be superior or non-inferior in safety and efficacy trials compared with 1st generation DES.

However, it is difficult to know if there are any differences in efficacy and safety between the EES, the ZES-R, and the BES, in real world practice due to the lack of data comparing these three 2nd generation DES directly. This study provides the evidence for the CHOICE of stent when physicians are treating patients by percutaneous coronary intervention.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Coronary Artery Disease

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Allocation Method

RANDOMIZED

Intervention Model

PARALLEL

BES EES ZES-R
Primary Study Purpose

TREATMENT

Blinding Strategy

SINGLE

Participants

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

Biolimus-eluting stent

Biomatrix stent, Biosensors, USA Biomatrix Flex stent, Biosensors, USA

Group Type ACTIVE_COMPARATOR

Biolimus-eluting stent

Intervention Type DEVICE

Biolimus-eluting stent (BES, BioMatrix or BioMatrix Flex, Biosensors, USA) has bio-degradable polymer which is consisted with poly-lactic acid (PLA) and degraded into H2O and CO2 while releasing the biolimus. BES would be expected to reduce the stent thrombosis comparing with the DES with durable polymer.

Everolimus-eluting stent

Xience Prime stent, Abbott, USA Xience V stent, Abbott, USA

Group Type ACTIVE_COMPARATOR

Everolimus-eluting stent

Intervention Type DEVICE

Everolimus-eluting stent (EES, Xience V or Xience Prime, Abbott, USA) use the MULTILINK VISION stent platform and durable polymer containing everolimus. It has the thinnest strut thickness among the available DES in Korea.

Zotarolimus-eluting stent

Endeavor resolute, Medtronic, USA Endeavor resolute integrity, Medtronic, USA

Group Type ACTIVE_COMPARATOR

Zotarolimus-eluting stent

Intervention Type DEVICE

Zotarolimus-eluting stent with biolinx polymer (ZES, Endeavor Resolute or Endeavor Resolute Intergrity, Medtronic, USA) has DRIVER stent platform. The durable polymer in this DES has changed from phosphorylcholine (PC) polymer which was used in Endeavor to Biolinx polymer which has more biocompatible features.

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

Biolimus-eluting stent

Biolimus-eluting stent (BES, BioMatrix or BioMatrix Flex, Biosensors, USA) has bio-degradable polymer which is consisted with poly-lactic acid (PLA) and degraded into H2O and CO2 while releasing the biolimus. BES would be expected to reduce the stent thrombosis comparing with the DES with durable polymer.

Intervention Type DEVICE

Everolimus-eluting stent

Everolimus-eluting stent (EES, Xience V or Xience Prime, Abbott, USA) use the MULTILINK VISION stent platform and durable polymer containing everolimus. It has the thinnest strut thickness among the available DES in Korea.

Intervention Type DEVICE

Zotarolimus-eluting stent

Zotarolimus-eluting stent with biolinx polymer (ZES, Endeavor Resolute or Endeavor Resolute Intergrity, Medtronic, USA) has DRIVER stent platform. The durable polymer in this DES has changed from phosphorylcholine (PC) polymer which was used in Endeavor to Biolinx polymer which has more biocompatible features.

Intervention Type DEVICE

Other Intervention Names

Discover alternative or legacy names that may be used to describe the listed interventions across different sources.

Biomatrix, Biosensors, USA Biomatrix flex, Biosensors, USA Xience V, Abbott, USA Xience Prime, Abbott, USA Endeavor Resolute, Medtronic, USA Endeavor Resolute Integrity, Medtronic, USA

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

* Age \> 19 years
* Subject is able to verbally confirm understanding of risks, benefits and treatment alternatives of receiving the drug-eluting stent(s) and he/she or his/her legally authorized representative provides written informed consent prior to any study related procedure
* Subject must have significant stenosis (\>50% by visual estimate) on a native or in-stent coronary artery
* Subject must have evidence of myocardial ischemia (e.g., stable, unstable angina, recent infarction, acute myocardial infarction, positive functional study or a reversible changes in the ECG consistent with ischemia). In subjects with coronary artery stenosis \>75%, evidence of myocardial ischemia does not have to be documented

Exclusion Criteria

* Subject has a known hypersensitivity or contraindication to any of the following medications: heparin, aspirin, clopidogrel, prasugrel, ticagrelor, biolimus A9, everolimus, zotarolimus, stainless steel, cobalt chromium, contrast media (Patients with documented sensitivity to contrast media, which can be effectively premedicated with steroid and diphenhydramine may be enrolled. However, those with true anaphylaxis to prior contrast media should not be enrolled.)
* Subject in use of systemic (intravenous) biolimus A9, everolimus or zotarolimus within 12 months.
* Female subject of childbearing potential, unless a recent pregnancy test is negative, who possibly plans to become pregnant any time after enrollment into this study
* Subject planned an elective surgical procedure that would necessitate interruption of antiplatelet during the first 12 months post enrollment
* Subject with non-cardiac co-morbid condition with life expectancy \< 2 year or that may result in protocol non-compliance (per site investigator's medical judgment)
* Subject with cardiogenic shock at presentation
* Subject who are actively participating in another drug or device investigational study, who have not completed the primary end point follow-up period
Minimum Eligible Age

18 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

No

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

Gangwon Cardiovascular Health Research Institute

OTHER

Sponsor Role collaborator

Yonsei University

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Yoon Junghan

Professor of Cardiology, Department of Internal Medicine

Responsibility Role PRINCIPAL_INVESTIGATOR

Principal Investigators

Learn about the lead researchers overseeing the trial and their institutional affiliations.

Junghan Yoon, M.D., Ph.D.

Role: PRINCIPAL_INVESTIGATOR

Wonju Chrisitian Hospital

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

Wonju Christian Hospital

Wŏnju, Gangwon-do, South Korea

Site Status

Chonnam National University Hospital

Chuncheon, , South Korea

Site Status

Daegu Catholic University Hospital

Daegu, , South Korea

Site Status

Inha University Hospital

Incheon, , South Korea

Site Status

Suncheon St. Carollo Hospital

Suncheon, , South Korea

Site Status

Countries

Review the countries where the study has at least one active or historical site.

South Korea

References

Explore related publications, articles, or registry entries linked to this study.

Kastrati A, Dibra A, Mehilli J, Mayer S, Pinieck S, Pache J, Dirschinger J, Schomig A. Predictive factors of restenosis after coronary implantation of sirolimus- or paclitaxel-eluting stents. Circulation. 2006 May 16;113(19):2293-300. doi: 10.1161/CIRCULATIONAHA.105.601823. Epub 2006 May 8.

Reference Type BACKGROUND
PMID: 16682614 (View on PubMed)

Moses JW, Leon MB, Popma JJ, Fitzgerald PJ, Holmes DR, O'Shaughnessy C, Caputo RP, Kereiakes DJ, Williams DO, Teirstein PS, Jaeger JL, Kuntz RE; SIRIUS Investigators. Sirolimus-eluting stents versus standard stents in patients with stenosis in a native coronary artery. N Engl J Med. 2003 Oct 2;349(14):1315-23. doi: 10.1056/NEJMoa035071.

Reference Type BACKGROUND
PMID: 14523139 (View on PubMed)

Pfisterer M, Brunner-La Rocca HP, Buser PT, Rickenbacher P, Hunziker P, Mueller C, Jeger R, Bader F, Osswald S, Kaiser C; BASKET-LATE Investigators. Late clinical events after clopidogrel discontinuation may limit the benefit of drug-eluting stents: an observational study of drug-eluting versus bare-metal stents. J Am Coll Cardiol. 2006 Dec 19;48(12):2584-91. doi: 10.1016/j.jacc.2006.10.026. Epub 2006 Nov 2.

Reference Type BACKGROUND
PMID: 17174201 (View on PubMed)

Stone GW, Ellis SG, Cox DA, Hermiller J, O'Shaughnessy C, Mann JT, Turco M, Caputo R, Bergin P, Greenberg J, Popma JJ, Russell ME; TAXUS-IV Investigators. A polymer-based, paclitaxel-eluting stent in patients with coronary artery disease. N Engl J Med. 2004 Jan 15;350(3):221-31. doi: 10.1056/NEJMoa032441.

Reference Type BACKGROUND
PMID: 14724301 (View on PubMed)

Holmes DR Jr, Kereiakes DJ, Laskey WK, Colombo A, Ellis SG, Henry TD, Popma JJ, Serruys PW, Kimura T, Williams DO, Windecker S, Krucoff MW. Thrombosis and drug-eluting stents: an objective appraisal. J Am Coll Cardiol. 2007 Jul 10;50(2):109-18. doi: 10.1016/j.jacc.2007.04.032. Epub 2007 May 22.

Reference Type BACKGROUND
PMID: 17616294 (View on PubMed)

Iakovou I, Schmidt T, Bonizzoni E, Ge L, Sangiorgi GM, Stankovic G, Airoldi F, Chieffo A, Montorfano M, Carlino M, Michev I, Corvaja N, Briguori C, Gerckens U, Grube E, Colombo A. Incidence, predictors, and outcome of thrombosis after successful implantation of drug-eluting stents. JAMA. 2005 May 4;293(17):2126-30. doi: 10.1001/jama.293.17.2126.

Reference Type BACKGROUND
PMID: 15870416 (View on PubMed)

Cutlip DE, Baim DS, Ho KK, Popma JJ, Lansky AJ, Cohen DJ, Carrozza JP Jr, Chauhan MS, Rodriguez O, Kuntz RE. Stent thrombosis in the modern era: a pooled analysis of multicenter coronary stent clinical trials. Circulation. 2001 Apr 17;103(15):1967-71. doi: 10.1161/01.cir.103.15.1967.

Reference Type BACKGROUND
PMID: 11306525 (View on PubMed)

Doyle B, Rihal CS, O'Sullivan CJ, Lennon RJ, Wiste HJ, Bell M, Bresnahan J, Holmes DR Jr. Outcomes of stent thrombosis and restenosis during extended follow-up of patients treated with bare-metal coronary stents. Circulation. 2007 Nov 20;116(21):2391-8. doi: 10.1161/CIRCULATIONAHA.107.707331. Epub 2007 Nov 5.

Reference Type BACKGROUND
PMID: 17984377 (View on PubMed)

Daemen J, Wenaweser P, Tsuchida K, Abrecht L, Vaina S, Morger C, Kukreja N, Juni P, Sianos G, Hellige G, van Domburg RT, Hess OM, Boersma E, Meier B, Windecker S, Serruys PW. Early and late coronary stent thrombosis of sirolimus-eluting and paclitaxel-eluting stents in routine clinical practice: data from a large two-institutional cohort study. Lancet. 2007 Feb 24;369(9562):667-78. doi: 10.1016/S0140-6736(07)60314-6.

Reference Type BACKGROUND
PMID: 17321312 (View on PubMed)

Roukoz H, Bavry AA, Sarkees ML, Mood GR, Kumbhani DJ, Rabbat MG, Bhatt DL. Comprehensive meta-analysis on drug-eluting stents versus bare-metal stents during extended follow-up. Am J Med. 2009 Jun;122(6):581.e1-10. doi: 10.1016/j.amjmed.2008.12.019.

Reference Type BACKGROUND
PMID: 19486720 (View on PubMed)

Kirtane AJ, Gupta A, Iyengar S, Moses JW, Leon MB, Applegate R, Brodie B, Hannan E, Harjai K, Jensen LO, Park SJ, Perry R, Racz M, Saia F, Tu JV, Waksman R, Lansky AJ, Mehran R, Stone GW. Safety and efficacy of drug-eluting and bare metal stents: comprehensive meta-analysis of randomized trials and observational studies. Circulation. 2009 Jun 30;119(25):3198-206. doi: 10.1161/CIRCULATIONAHA.108.826479. Epub 2009 Jun 15.

Reference Type BACKGROUND
PMID: 19528338 (View on PubMed)

Mauri L, Hsieh WH, Massaro JM, Ho KK, D'Agostino R, Cutlip DE. Stent thrombosis in randomized clinical trials of drug-eluting stents. N Engl J Med. 2007 Mar 8;356(10):1020-9. doi: 10.1056/NEJMoa067731. Epub 2007 Feb 12.

Reference Type BACKGROUND
PMID: 17296821 (View on PubMed)

Stone GW, Moses JW, Ellis SG, Schofer J, Dawkins KD, Morice MC, Colombo A, Schampaert E, Grube E, Kirtane AJ, Cutlip DE, Fahy M, Pocock SJ, Mehran R, Leon MB. Safety and efficacy of sirolimus- and paclitaxel-eluting coronary stents. N Engl J Med. 2007 Mar 8;356(10):998-1008. doi: 10.1056/NEJMoa067193. Epub 2007 Feb 12.

Reference Type BACKGROUND
PMID: 17296824 (View on PubMed)

Caixeta A, Lansky AJ, Serruys PW, Hermiller JB, Ruygrok P, Onuma Y, Gordon P, Yaqub M, Miquel-Hebert K, Veldhof S, Sood P, Su X, Jonnavithula L, Sudhir K, Stone GW; SPIRIT II and III Investigators. Clinical follow-up 3 years after everolimus- and paclitaxel-eluting stents: a pooled analysis from the SPIRIT II (A Clinical Evaluation of the XIENCE V Everolimus Eluting Coronary Stent System in the Treatment of Patients With De Novo Native Coronary Artery Lesions) and SPIRIT III (A Clinical Evaluation of the Investigational Device XIENCE V Everolimus Eluting Coronary Stent System [EECSS] in the Treatment of Subjects With De Novo Native Coronary Artery Lesions) randomized trials. JACC Cardiovasc Interv. 2010 Dec;3(12):1220-8. doi: 10.1016/j.jcin.2010.07.017.

Reference Type BACKGROUND
PMID: 21232715 (View on PubMed)

Kedhi E, Joesoef KS, McFadden E, Wassing J, van Mieghem C, Goedhart D, Smits PC. Second-generation everolimus-eluting and paclitaxel-eluting stents in real-life practice (COMPARE): a randomised trial. Lancet. 2010 Jan 16;375(9710):201-9. doi: 10.1016/S0140-6736(09)62127-9. Epub 2010 Jan 7.

Reference Type BACKGROUND
PMID: 20060578 (View on PubMed)

Stone GW, Midei M, Newman W, Sanz M, Hermiller JB, Williams J, Farhat N, Mahaffey KW, Cutlip DE, Fitzgerald PJ, Sood P, Su X, Lansky AJ; SPIRIT III Investigators. Comparison of an everolimus-eluting stent and a paclitaxel-eluting stent in patients with coronary artery disease: a randomized trial. JAMA. 2008 Apr 23;299(16):1903-13. doi: 10.1001/jama.299.16.1903.

Reference Type BACKGROUND
PMID: 18430909 (View on PubMed)

Stone GW, Rizvi A, Sudhir K, Newman W, Applegate RJ, Cannon LA, Maddux JT, Cutlip DE, Simonton CA, Sood P, Kereiakes DJ; SPIRIT IV Investigators. Randomized comparison of everolimus- and paclitaxel-eluting stents. 2-year follow-up from the SPIRIT (Clinical Evaluation of the XIENCE V Everolimus Eluting Coronary Stent System) IV trial. J Am Coll Cardiol. 2011 Jun 28;58(1):19-25. doi: 10.1016/j.jacc.2011.02.022. Epub 2011 Apr 21.

Reference Type BACKGROUND
PMID: 21514084 (View on PubMed)

Serruys PW, Silber S, Garg S, van Geuns RJ, Richardt G, Buszman PE, Kelbaek H, van Boven AJ, Hofma SH, Linke A, Klauss V, Wijns W, Macaya C, Garot P, DiMario C, Manoharan G, Kornowski R, Ischinger T, Bartorelli A, Ronden J, Bressers M, Gobbens P, Negoita M, van Leeuwen F, Windecker S. Comparison of zotarolimus-eluting and everolimus-eluting coronary stents. N Engl J Med. 2010 Jul 8;363(2):136-46. doi: 10.1056/NEJMoa1004130. Epub 2010 Jun 16.

Reference Type BACKGROUND
PMID: 20554978 (View on PubMed)

Silber S, Windecker S, Vranckx P, Serruys PW; RESOLUTE All Comers investigators. Unrestricted randomised use of two new generation drug-eluting coronary stents: 2-year patient-related versus stent-related outcomes from the RESOLUTE All Comers trial. Lancet. 2011 Apr 9;377(9773):1241-7. doi: 10.1016/S0140-6736(11)60395-4. Epub 2011 Apr 1.

Reference Type BACKGROUND
PMID: 21459430 (View on PubMed)

Stefanini GG, Kalesan B, Serruys PW, Heg D, Buszman P, Linke A, Ischinger T, Klauss V, Eberli F, Wijns W, Morice MC, Di Mario C, Corti R, Antoni D, Sohn HY, Eerdmans P, van Es GA, Meier B, Windecker S, Juni P. Long-term clinical outcomes of biodegradable polymer biolimus-eluting stents versus durable polymer sirolimus-eluting stents in patients with coronary artery disease (LEADERS): 4 year follow-up of a randomised non-inferiority trial. Lancet. 2011 Dec 3;378(9807):1940-8. doi: 10.1016/S0140-6736(11)61672-3. Epub 2011 Nov 8.

Reference Type BACKGROUND
PMID: 22075451 (View on PubMed)

Windecker S, Serruys PW, Wandel S, Buszman P, Trznadel S, Linke A, Lenk K, Ischinger T, Klauss V, Eberli F, Corti R, Wijns W, Morice MC, di Mario C, Davies S, van Geuns RJ, Eerdmans P, van Es GA, Meier B, Juni P. Biolimus-eluting stent with biodegradable polymer versus sirolimus-eluting stent with durable polymer for coronary revascularisation (LEADERS): a randomised non-inferiority trial. Lancet. 2008 Sep 27;372(9644):1163-73. doi: 10.1016/S0140-6736(08)61244-1. Epub 2008 Aug 31.

Reference Type BACKGROUND
PMID: 18765162 (View on PubMed)

Luscher TF, Steffel J, Eberli FR, Joner M, Nakazawa G, Tanner FC, Virmani R. Drug-eluting stent and coronary thrombosis: biological mechanisms and clinical implications. Circulation. 2007 Feb 27;115(8):1051-8. doi: 10.1161/CIRCULATIONAHA.106.675934.

Reference Type BACKGROUND
PMID: 17325255 (View on PubMed)

Youn YJ, Lee JW, Ahn SG, Lee SH, Yoon J, Park KS, Lee JB, Yoo SY, Lim DS, Cho JH, Choi CU, Jeong MH, Han KR, Cha KS, Lee SY, Choi HH, Choi JW, Hyon MS, Kim MH. Randomized Comparison of Everolimus- and Zotarolimus-Eluting Coronary Stents With Biolimus-Eluting Stents in All-Comer Patients. Circ Cardiovasc Interv. 2020 Mar;13(3):e008525. doi: 10.1161/CIRCINTERVENTIONS.119.008525. Epub 2020 Mar 12.

Reference Type DERIVED
PMID: 32160779 (View on PubMed)

Youn YJ, Lee JW, Ahn SG, Lee SH, Choi HH, Choi H, Choi CU, Lee JB, Cho JH, Kang TS, Cho BR, Cha KS, Kim MH, Hyon MS, Cheong SS, Lim DS, Han KR, Jeong MH, Park KS, Yoon J. Study design and rationale of "a multicenter, open-labeled, randomized controlled trial comparing three 2nd-generation drug-eluting stents in real-world practice" (CHOICE trial). Am Heart J. 2013 Aug;166(2):224-9. doi: 10.1016/j.ahj.2013.04.014. Epub 2013 Jun 19.

Reference Type DERIVED
PMID: 23895804 (View on PubMed)

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

CHOICE

Identifier Type: -

Identifier Source: org_study_id