ComparisiOn of Neointimal coVerage betwEen ZES and EES Using OCT at 3 Months
NCT ID: NCT01091740
Last Updated: 2012-01-31
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
COMPLETED
PHASE4
40 participants
INTERVENTIONAL
2009-08-31
2010-08-31
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Comparison of Neointimal Coverage Between Zotarolimus Eluting Stent and Everolimus Eluting Stent
NCT00894062
Late Stent Strut Apposition and Coverage After Drug-Eluting Stent Implantation by OCT in Patients With AMI
NCT02770651
Test Safety and Efficacy of Zotarolimus- and Everolimus-Eluting Stents (ZES/EES) Assessed by Optical Coherence Tomography
NCT01230723
TRANSFORM OCT TRiple Assessment of Neointima Stent FOrmation to Reabsorbable polyMer With Optical Coherence Tomography
NCT01972022
Assessment of Stent Malapposition and Neointimal Coverage on Optical coHerence Tomography at Post-procedure and 3 Months After Platinum Chromium Alloy Of the Element™ Stent Implantation
NCT01581515
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
Both everolimus eluting stent (EES) was recently introduced and ZES resolute also will be available in the near future in Korea. Previous phosphorylcholine polymer was replaced with new, proprietary polymer which can provide extended elution kinetics in ZES resolute. Therefore, efficacy to suppress the neointimal growth might be improved but, safety for neointimal coverage needs to be evaluated in human coronary artery. Both new DESs are cobalt chrominum stent with thin stent strut and reported similar efficacy for suppressing the neointima growth. Also, endothelial coverage over stent strut occurred earlier compared to previous DESs (SES or PES) in animal experiments. But, there has been no data for neointimal coverage and malapposition of ZES resolute and EES using OCT in human coronary artery.
Recent paper according to Kubo et al reported that serial OCT examinations demonstrated markedly different vascular response up to 9 months after SES implantation between unstable angina and stable angina patients. These findings implied that initial native vessel status, which covered with stent, might be important and related with neoinitmal coverage and malapposition. But, there is little data evaluated the relationship between initial lesion status and neointimal coverage or late malapposition with OCT.
Therefore, this study will 1) evaluate the neointimal coverage and malapposition at 3 month after ZES resolute and EES implantation and 2) compare them between ZES resolute and EES at 3 months after stent implantation.
2\. STUDY OBJECTIVE This study is an prospective open labeled randomized study to compare the neointimal coverage of ZES resolute (Endeavor® resolute) and EES (Xience®) in 3 month after stent implantation by OCT.
2.1. Primary end point The primary endpoint is to compare the pattern of neointimal coverage between ZES resoute (Endeavor® resolute) and EES (Xience®) at 3 months after stent implantation by OCT.
2.2. Secondary end point The secondary objective of this study is to evaluate neointimal growth between ZES resolute and EES at 3 months and 2) to compare the difference in early and late malapposition between ZES resolute and EES at 3 months.
3\. Methods and Design
3.1 Patient enrollment Patients with stable angina pectoris who present to the cath lab for non-emergent PCI are eligible for participation. A patient is considered to be enrolled if they meet all of the inclusion and have none of the exclusion criteria.
Inclusion criteria
* Significant coronary de novo lesion (\> 70% by quantitative angiographic analysis)
* Patients with stable angina pectoris who are considered for coronary revascularization.
* Reference vessel diameter of 2.5 to 3.5 mm by operator assessment
Exclusion criteria
The criteria for exclusion were
* Acute coronary syndrome
* Contraindication to anti-platelet agents
* Proximal leison within 15 mm from ostium
* Treated with any DES within 1 year at other vessel
* Creatinine level 2.0 mg/dL or ESRD
* Severe hepatic dysfunction (3 times normal reference values)
* Pregnant women or women with potential childbearing
* Complex lesion morphologies (aorto-ostial, unprotected Left main, chronic total occlusion)
* Target lesion is vein graft lesion
* Reference vessel \< 2.5 mm or \> 4.0mm diameter by visual
3.2. Sample Size and Statistical analysis
Calculation of the sample size could not be done because of observation study. Therefore, we decided to enroll 40 patients for 20 ZESs resolute and 20 EESs considering sufficient stent strut (over 3000 stent struts each group).
Results are expressed as the mean ±SD. Comparisons of discrete variables were made using the chi-square test or Fisher's Exact Test. Student t-tests were used for continuous variables. Because the distribution was skewed due to a small study sample, non-parametric tests (Mann-Whitney test for unpaired variables and Wilcoxon-signed rank test for paired variables) were used. All statistical analysis was performed with SPSS 13.0. (SPSS Inc., Chicago, IL, USA). A value of p\<0.05 was considered statistically significant.
4\. STUDY PROCEDURE
The cath lab will follow site standard operating procedures for PTCA and stenting. Stent overlapping is not allowed. Treatment of multiple vessels is acceptable. However, information will be collected on only one study lesion per patient.
Information will be collected and recorded on the treated study vessel including angiographic, IVUS and OCT parameters. The IVUS and OCT study should be checked in the procedure and follow up at 3 months angiography.
4.1. PROCEDURAL MATERIALS Endeavor ® resolute 2.75 to 3.5 mm All available length Drug Eluting Stent Xience ® 2.75 to 3.5 mm All available length
4.2 RANDOMIZATION Patients with native coronary arteries who fulfill all enrollment criteria will be randomized to receive either ZES (Endeavor®) resolute or EES (Xience or Promus®). Randomization will be performed in a 1:1 ratio of ZES or EES according to each clinical presentation.
4.3 STENT SELECTION The vessel size will be determined either by quantitative angiography or by IVUS for appropriate stent size selection.
4.4 IVUS ASSESSMENT IVUS assessment was performed using a commercially available IVUS system (Boston Scientific/ Scimed, Natick, MA). Studies were recorded on Index system (Echoplaque 2; INDEC Systems Inc, Mountain View, CA) for off-line analysis. Motorized transducer pullback permitted cross-sectional area measurements at 1mm axial increments throughout the length of the stent. All IVUS studies were performed after the intracoronary administration of 200 µg of nitroglycerin. The reference segment was the most visually normal cross section (largest lumen with least plaque burden) within 10mm proximal or distal to the lesion. Using the software, external elastic membrane (EEM) CSA (mm2), lumen CSA (mm2), minimal stent cross-sectional area (MSA); identified as the CSA at the tightest segment within stent, stent MLD were determined. The CSA at the proximal and the distal reference segments and at the most stenotic lesion as well as the CSA at the proximal and the distal stent edge was determined. A determination of the percent expansion was made by measuring the MSA and the average reference segment CSA. Average reference segment CSA is calculated as \[Proximal Reference segment CSA +Distal Reference segment CSA)/2\]. Plaque volume was calculated as vessel minus stent volume. Neointimal volume was calculated as stent minus lumen volume, and percentage (%) of neointimal obstruction was calculated as neointimal volume divided by stent volume. Neointimal coverage over stent surface and mean physical neointimal thickness were obtained by measuring circumferential stent length covered with neointimal hyperplasia (LN) and stent perimeter (LS) at every 1-mm cross-sectional image throughout the stented segment: (a) percentage of neointimal coverage over stent surface, calculated as total LN divided by total LS, and (b) mean physical neointimal thickness, calculated as mean neointimal area divided by mean LN for only the cross sections with detectable neointima.
4.5. OCT ASSESSMENT OCT measurements will be made as following methods: (Takano M, et al. Evaluation by Optical Coherence Tomography of Neointimal Coverage of Sirolimus-Eluting Stent Three Months After Implantation. Am J Cardiol 2007;99: 10331038)
Cross-sectional OCT images were analyzed at 1-mm intervals (every 15 frames). Neointimal hyperplasia (NIH) thickness inside stent struts was measured. Stent area and lumen area in every image were measured by manual trace and percent NIH area was calculated as percent NIH area = (\[stent area - lumen area\]/ stent area) / 100. Measured NIH thickness equal to 0 micro meter was defined as exposure, and maximum distance \> 110 micro meter between the strut surface and adjacent vessel surface (thickness of strut and polymer) was defined as malapposition. On an image of stent malapposition, lumen area was divided into an in-stent lumen area and an extra-stent lumen area. . Intracoronary thrombus was defined as a protruding mass beyond the stent strut into the lumen. Bifurcation lesions with major sidebranches were excluded from this analysis. Inter- and intraobserver variabilities were assessed by evaluation of 20 random cross- sectional images by 2 independent readers and by the same reader at 2 separate time points, respectively.
4.6. Follow-Up
All patients will be followed after hospital discharge. When patients come back in 3 and 9 months after the discharge due to clinical follow-up, the patient record will be updated.
1\. Clinical follow-up at 3, 9 months and 2 years after the procedure.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
RANDOMIZED
PARALLEL
TREATMENT
NONE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
ZES resolute (Endeavor Resolute)
ZES resolute (Endeavor Resolute)
2nd generation drug eluting stent, which is coated with zotarolimus
EES (Xience)
EES (Xience)
2nd generation drug eluting stent, which is coated with everolimus
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
ZES resolute (Endeavor Resolute)
2nd generation drug eluting stent, which is coated with zotarolimus
EES (Xience)
2nd generation drug eluting stent, which is coated with everolimus
Other Intervention Names
Discover alternative or legacy names that may be used to describe the listed interventions across different sources.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
* Patients with stable angina pectoris who are considered for coronary revascularization.
* Reference vessel diameter of 2.5 to 3.5 mm by operator assessment
Exclusion Criteria
* Contraindication to anti-platelet agents
* Proximal leison within 15 mm from ostium
* Treated with any DES within 1 year at other vessel
* Creatinine level 2.0 mg/dL or ESRD
* Severe hepatic dysfunction (3 times normal reference values)
* Pregnant women or women with potential childbearing
* Complex lesion morphologies (aorto-ostial, unprotected Left main, chronic total occlusion)
* Target lesion is vein graft lesion
* Reference vessel \< 2.5 mm or \> 4.0mm diameter by visual
20 Years
90 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Medtronic
INDUSTRY
Yonsei University
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Jung-Sun Kim
Assistant Professor
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
Jung-Sun Kim, MD, Ph D
Role: PRINCIPAL_INVESTIGATOR
Division of Cardiology, Cardiovascular Hospital, Yonsei University
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Dongsan Medical Center, Keimyung University College of Medicine
Daegu, , South Korea
Division of Cardiology, Cardiovascular Hospital, Yonsei University
Seoul, , South Korea
Countries
Review the countries where the study has at least one active or historical site.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
1-2009-0010
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.