Effect of TCFA on Neointimal Coverage After PCI at 9 Months Follow-up

NCT ID: NCT02384837

Last Updated: 2016-12-06

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

COMPLETED

Total Enrollment

33 participants

Study Classification

OBSERVATIONAL

Study Start Date

2014-12-31

Study Completion Date

2016-11-30

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

Although drug-eluting stents have reduced rates of restenosis and late lumen loss compared with bare metal stents, late stent thrombosis (LST), a life-threatening complication of this technology, has emerged as a major concern. Researches indicated incomplete neointimal coverage of stent struts as the most important morphometric predictor of LST. Pathological research showed stenting disruption of adjacent vulnerable plaques can precipitate LST, Meanwhile, thin-cap fibroatheromas (TCFA) as the most important predictor of Major Adverse Cardiovascular. Therefore, there is a hypothesis that TCFA may impair intimal healing which are prone to LST in vivo.

Optical coherence tomography (OCT)is a high-resolution (\<10 µm), catheter-based imaging modality capable of investigating detailed coronary plaque morphology in vivo.This study aimed to observe that TCFA will arise what of the effect on intimal healing of stent struts on the lesions which fractional flow reserve (FFR)≤0.75 after EXCEL biodegradable polymer-coated sirolimus-eluting stent was implanted at 9 months follow up: evaluated by OCT and FFR

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

The primary end point is to Neointimal coverage after 9 months of the stent implantation.

Quality assurance plan that addresses data validation and registry procedures, including any plans for site monitoring and auditing.

Data checks to compare data entered into the registry against predefined rules for range or consistency with other data fields in the registry.

Source data verification to assess the accuracy, completeness, or representativeness of registry data by comparing the data to external data sources (e.g., medical records, paper or electronic case report forms, or interactive voice response systems).

Data dictionary that contains detailed descriptions of each variable used by the registry, including the source of the variable, coding information if used and normal ranges if relevant.

Standard Operating Procedures to address registry operations and analysis activities, such as patient recruitment, data collection, data management, data analysis, reporting for adverse events, and change management.

Sample size assessment to specify the number of participants or participant years necessary to demonstrate an effect.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Unrecognized Condition

Keywords

Explore important study keywords that can help with search, categorization, and topic discovery.

national Cather Lad Interventional Imaging Training Base

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Observational Model Type

COHORT

Study Time Perspective

PROSPECTIVE

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

TCFA

EXCEL biodegradable polymer-coated sirolimus-eluting stent was implanted on lesions which include TCFA (\>=1)

EXCEL biodegradable polymer-coated sirolimus-eluting stent

Intervention Type DEVICE

NO-TCFA

EXCEL biodegradable polymer-coated sirolimus-eluting stent was implanted on lesions which is not include TCFA

EXCEL biodegradable polymer-coated sirolimus-eluting stent

Intervention Type DEVICE

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

EXCEL biodegradable polymer-coated sirolimus-eluting stent

Intervention Type DEVICE

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

* 18yrs≤Age≤75yrs
* stability and unstable angina pectoris (AP), chronic myocardial infarction (OMI) or confirmed myocardial ischemia
* De novo lesion at native coronary artery(Up to two target lesions)
* Lesion length ≤32mm
* RVD 2.5mm~4.0mm
* DS%≥70% by visual test
* Coronary artery bypass surgery (coronary artery bypass grafting) patients
* Subjects are willing to follow the specified requirements follow-up
* To understand the purpose of the trial and willing to sign informed consent and accept clinical follow-up

Exclusion Criteria

* AMI within 7 days.
* CTO (TIMI 0), the left main lesion, ostial lesion and transplant vascular lesions, the bifurcation lesion (reference collateral blood vessel diameter of 2.5 mm or higher), stent restenosis lesions and to deal with three pathological changes;
* Severe calcified lesion unable to predilate.
* The distortion of the stent was hampered by lesions.
* NYHA≥Ⅲ or LVEF\<40%.
* Prior PCI within 1 year.
* Pregnancy or lactation, and planning pregnancy or lactation.
* Subjects have bleeding tendency or blood coagulation dysfunction or PCI contraindications, or anticoagulant therapy taboo or can't continue to take DAPT at least 1 year.
* There are other diseases (such as cancer,malignant tumor ,congestive heart failure,organ transplantation or candidate) or abuse history (alcohol cocaine heroin, etc.), scheme compliance is poor, interference related data explanation or the limited life (\< 1 year).
* To aspirin heparin clopidogrel cobalt chromium alloy rapamycin PLA polymer contrast agent of one of allergy.
* Serious liver and kidney function are not complete subject(ALT and AST were three times greater than the upper limit of normal).
* Before enrolling to participate in other clinical trials and not reached the primary endpoint.
* Non-compliant subject and could not finish the trial in accordance with the requirements of the subjects.
Minimum Eligible Age

18 Years

Maximum Eligible Age

75 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

No

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

General Hospital of Chinese Armed Police Forces

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Responsibility Role SPONSOR

Principal Investigators

Learn about the lead researchers overseeing the trial and their institutional affiliations.

HUILIANG LIU, MD

Role: STUDY_CHAIR

CHINESE ARMED POLICE FORCE GENRAL HOSPITAL

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

Cardiology Department, Chinese Armed Police Force Genral Hospital, Beijing China

Beijing, , China

Site Status

Countries

Review the countries where the study has at least one active or historical site.

China

References

Explore related publications, articles, or registry entries linked to this study.

Ozaki Y, Okumura M, Ismail TF, Naruse H, Hattori K, Kan S, Ishikawa M, Kawai T, Takagi Y, Ishii J, Prati F, Serruys PW. The fate of incomplete stent apposition with drug-eluting stents: an optical coherence tomography-based natural history study. Eur Heart J. 2010 Jun;31(12):1470-6. doi: 10.1093/eurheartj/ehq066. Epub 2010 Apr 2.

Reference Type BACKGROUND
PMID: 20363765 (View on PubMed)

Finn AV, Joner M, Nakazawa G, Kolodgie F, Newell J, John MC, Gold HK, Virmani R. Pathological correlates of late drug-eluting stent thrombosis: strut coverage as a marker of endothelialization. Circulation. 2007 May 8;115(18):2435-41. doi: 10.1161/CIRCULATIONAHA.107.693739. Epub 2007 Apr 16.

Reference Type RESULT
PMID: 17438147 (View on PubMed)

Matsumoto D, Shite J, Shinke T, Otake H, Tanino Y, Ogasawara D, Sawada T, Paredes OL, Hirata K, Yokoyama M. Neointimal coverage of sirolimus-eluting stents at 6-month follow-up: evaluated by optical coherence tomography. Eur Heart J. 2007 Apr;28(8):961-7. doi: 10.1093/eurheartj/ehl413. Epub 2006 Nov 29.

Reference Type RESULT
PMID: 17135281 (View on PubMed)

Kubo T, Imanishi T, Kitabata H, Kuroi A, Ueno S, Yamano T, Tanimoto T, Matsuo Y, Masho T, Takarada S, Tanaka A, Nakamura N, Mizukoshi M, Tomobuchi Y, Akasaka T. Comparison of vascular response after sirolimus-eluting stent implantation between patients with unstable and stable angina pectoris: a serial optical coherence tomography study. JACC Cardiovasc Imaging. 2008 Jul;1(4):475-84. doi: 10.1016/j.jcmg.2008.03.012.

Reference Type RESULT
PMID: 19356470 (View on PubMed)

Stone GW, Maehara A, Lansky AJ, de Bruyne B, Cristea E, Mintz GS, Mehran R, McPherson J, Farhat N, Marso SP, Parise H, Templin B, White R, Zhang Z, Serruys PW; PROSPECT Investigators. A prospective natural-history study of coronary atherosclerosis. N Engl J Med. 2011 Jan 20;364(3):226-35. doi: 10.1056/NEJMoa1002358.

Reference Type RESULT
PMID: 21247313 (View on PubMed)

Farb A, Burke AP, Kolodgie FD, Virmani R. Pathological mechanisms of fatal late coronary stent thrombosis in humans. Circulation. 2003 Oct 7;108(14):1701-6. doi: 10.1161/01.CIR.0000091115.05480.B0. Epub 2003 Sep 22.

Reference Type RESULT
PMID: 14504181 (View on PubMed)

Guagliumi G, Sirbu V, Musumeci G, Bezerra HG, Aprile A, Kyono H, Fiocca L, Matiashvili A, Lortkipanidze N, Vassileva A, Popma JJ, Allocco DJ, Dawkins KD, Valsecchi O, Costa MA. Strut coverage and vessel wall response to a new-generation paclitaxel-eluting stent with an ultrathin biodegradable abluminal polymer: Optical Coherence Tomography Drug-Eluting Stent Investigation (OCTDESI). Circ Cardiovasc Interv. 2010 Aug;3(4):367-75. doi: 10.1161/CIRCINTERVENTIONS.110.950154. Epub 2010 Jul 20.

Reference Type RESULT
PMID: 20647562 (View on PubMed)

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

Effect of TCFA

Identifier Type: -

Identifier Source: org_study_id