Intravascular ULTrasound Guided Versus Conventional Angiography Guided Strategy to Deploy Zotarolimus and Everolimus Eluting Third Generation Stents in the Long Coronary Artery Lesions: ULTRA-ZET Trial

NCT ID: NCT01979744

Last Updated: 2019-03-28

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

COMPLETED

Clinical Phase

NA

Total Enrollment

568 participants

Study Classification

INTERVENTIONAL

Study Start Date

2013-10-31

Study Completion Date

2017-10-31

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

Although first generation DES reduced instent restenosis, still remained the unsolved problems such as stent thrombosis and restenosis in the era of DES. Second generation DES had been developed to improve the biocompatibility of stent coating focused on polymer compared to first generation DES, so that second generation stents showed better outcomes compared with first generation DES. On the other hands, in third generation DES, further refinement of DES involved more flexible stent platform. Promus ElementTM (Everolimus eluting stent, Boston Scientific, Nastick, MA) and Resolute Integrity® (Zotarolimus eluting stent, Medtronic Vascular, Santa Rosa, CA) are the third generation drug eluting stents which are designed to increase flexibility. In previous randomized controlled studies, both of these stents have shown at least non-inferior angiographic and clinical outcomes compared to second generation DES. However, there is lack of data about comparison of angiographic and clinical outcomes between Promus ElementTM and Resolute Integrity®.

IVUS is one of the widely used intracoronary imaging devices to provide more reproducible and accurate information about coronary anatomy than angiography in current practice.8 Optimal stent expansion assessed by intravascular ultrasound (IVUS) has been reported as an important factor to prevent stent thrombosis or restenosis.9 Accordingly, there have been many studies to evaluate the procedural or clinical benefit of IVUS guided angioplasty. However, The clinical benefit of IVUS-guided angioplasty with stent implantation is still in a controversy. In the previous studies, IVUS-guided stent implantation showed positive or negative beneficial effect on clinical outcomes according to their study subjects. However, the stents used in the previous studies are less useful in current practice of cardiology and there is lack of data of 3rd generation DES, which have different stent profiles and outcomes with their predecessors.

Thus we would perform a prospective randomized study in order to compare the efficacy of IVUS-guided angioplasty with conventional angioplasty-guided procedure in the long coronary lesion. Our main hypothesis is IVUS-guided 3rd generation DES implantation in the long coronary lesions would have better clinical outcomes compared with conventional angiography-guided strategy. We also intend to assess the clinical outcomes after Promus ElementTM and Resolute Integrity® implantation.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Coronary Artery Disease

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Allocation Method

RANDOMIZED

Intervention Model

PARALLEL

Primary Study Purpose

TREATMENT

Blinding Strategy

NONE

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

Resolute Integrity - IVUS

Resolute Integrity - IVUS arm

Group Type EXPERIMENTAL

IVUS guided percutaneous coronary angioplasty with Resolute integrity stent insertion

Intervention Type PROCEDURE

Resolute integrity stent implantation (diameter from 2.5mm to 3.5mm, length 30, 34, 38mm) The size and number of stents and post-dilation will be determined on physician's discrete within the range allowed in this study protocol. All procedure will be performed according to current standard technique. IVUS will be used to assess the anatomic characteristics of lesion and determine appropriate stent size and length. Additional stent implantation or post dilation will be allowed according to attending physician's discrete based on IVUS results.

Resolute Integrity - Angio

Resolute Integrity - Angio arm

Group Type ACTIVE_COMPARATOR

Angiography guided percutaneous coronary angioplasty with Resolute integrity stent insertion

Intervention Type DEVICE

Resolute integrity stent implantation (diameter from 2.5mm to 3.5mm, length 30, 34, 38mm) The size and number of stents and post-dilation will be determined on physician's discrete within the range allowed in this study protocol. All procedure will be performed according to current standard technique. Additional stent implantation or post dilation will be allowed according to attending physician's discrete. IVUS will be not used in this arm.

Promus - Angio

Promus - Angio arm

Group Type ACTIVE_COMPARATOR

Angiography guided percutaneous coronary angioplasty with Promus element stent implantation

Intervention Type DEVICE

Promus element stent implantation (diameter from 2.5mm to 3.5mm, length 28, 32, 36mm) The size and number of stents and post-dilation will be determined on physician's discrete within the range allowed in this study protocol. All procedure will be performed according to current standard technique. Additional stent implantation or post dilation will be allowed according to attending physician's discrete. IVUS will be not used in this arm.

Promus - IVUS

Promus - IVUS arm

Group Type ACTIVE_COMPARATOR

Angiography guided percutaneous coronary angioplasty with Promus element stent implantation

Intervention Type PROCEDURE

Promus element stent implantation (diameter from 2.5mm to 3.5mm, length 28, 32, 36mm) The size and number of stents and post-dilation will be determined on physician's discrete within the range allowed in this study protocol. All procedure will be performed according to current standard technique. IVUS will be used to assess the anatomic characteristics of lesion and determine appropriate stent size and length. Additional stent implantation or post dilation will be allowed according to attending physician's discrete based on IVUS results.

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

IVUS guided percutaneous coronary angioplasty with Resolute integrity stent insertion

Resolute integrity stent implantation (diameter from 2.5mm to 3.5mm, length 30, 34, 38mm) The size and number of stents and post-dilation will be determined on physician's discrete within the range allowed in this study protocol. All procedure will be performed according to current standard technique. IVUS will be used to assess the anatomic characteristics of lesion and determine appropriate stent size and length. Additional stent implantation or post dilation will be allowed according to attending physician's discrete based on IVUS results.

Intervention Type PROCEDURE

Angiography guided percutaneous coronary angioplasty with Resolute integrity stent insertion

Resolute integrity stent implantation (diameter from 2.5mm to 3.5mm, length 30, 34, 38mm) The size and number of stents and post-dilation will be determined on physician's discrete within the range allowed in this study protocol. All procedure will be performed according to current standard technique. Additional stent implantation or post dilation will be allowed according to attending physician's discrete. IVUS will be not used in this arm.

Intervention Type DEVICE

Angiography guided percutaneous coronary angioplasty with Promus element stent implantation

Promus element stent implantation (diameter from 2.5mm to 3.5mm, length 28, 32, 36mm) The size and number of stents and post-dilation will be determined on physician's discrete within the range allowed in this study protocol. All procedure will be performed according to current standard technique. Additional stent implantation or post dilation will be allowed according to attending physician's discrete. IVUS will be not used in this arm.

Intervention Type DEVICE

Angiography guided percutaneous coronary angioplasty with Promus element stent implantation

Promus element stent implantation (diameter from 2.5mm to 3.5mm, length 28, 32, 36mm) The size and number of stents and post-dilation will be determined on physician's discrete within the range allowed in this study protocol. All procedure will be performed according to current standard technique. IVUS will be used to assess the anatomic characteristics of lesion and determine appropriate stent size and length. Additional stent implantation or post dilation will be allowed according to attending physician's discrete based on IVUS results.

Intervention Type PROCEDURE

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

* Patients ≥ 19 years old
* Coronary artery disease and lesions which are candidate for treatment with drug eluting stent according to current clinical practice guidelines
* PCI for lesion(s) which needs a stent of 26mm or more
* Reference diameter from 2.25 to 4.0mm

Exclusion Criteria

* Restenosis lesion
* Reference vessel diameter \< 2.25 mm or \> 4.0mm
* Primary PCI for STEMI
* Contraindication to anti-platelet agents
* Treated with any DES within 3 months at other vessel
* Severe hepatic dysfunction (3 times normal reference values)
* Pregnant women or women with potential childbearing
* Life expectancy \< 1 year
Minimum Eligible Age

19 Years

Maximum Eligible Age

85 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

No

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

Yonsei University

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Responsibility Role SPONSOR

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

Division of Cardiology, Yonsei Cardiovascular Hospital, Yonsei University College of Medicine

Seoul, , South Korea

Site Status

Countries

Review the countries where the study has at least one active or historical site.

South Korea

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

1-2013-0052

Identifier Type: -

Identifier Source: org_study_id

More Related Trials

Additional clinical trials that may be relevant based on similarity analysis.

IVUS Controlled Stenting
NCT02128412 UNKNOWN NA