A New Method for Colorectal Cancer Screening: Colon Capsule Endoscopy Compared to Conventional Endoscopy
NCT ID: NCT00991003
Last Updated: 2009-10-07
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
COMPLETED
NA
59 participants
INTERVENTIONAL
2007-11-30
2008-05-31
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Prevention of colorectal cancer (CRC) is feasible through polypectomy on screening colonoscopy. Patient acceptance remains the main limiting factor for execution. Colon capsule endoscopy (CCE) might be a novel method for large populations.
Aims and methods:
Patients referred for screening means or lower gastrointestinal complaints were included in this single center pilot study. They underwent preparation and then ingested the capsule (PillCam Colon). Standard colonoscopy was performed the next morning. Significance was defined as polyps \>5mm in size. Performance of exams was by independent physician with blinding of results.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Colon Capsule Endoscopy (CCE) Versus Computed Tomographic Colonography (CTC) in the Identification of Colonic Polyps in a Screening Population.
NCT02754661
Experience and Enhancement: Improving Colonoscopic Polyp Detection
NCT00237276
Examination of the Large Intestine With Camera Capsule in Patients With Blood Stream Infection With Gut-associated Bacteria
NCT06919068
Colonoscopy by Videocapsuls Versus Standard Colonoscopy. Intra-individual Comparison for the Subject With a Medium or High Risk of Colorectal Cancer.
NCT00436514
Virtual Chromoendoscopy for Colitis Surveillance: A Feasibility Study
NCT02543021
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
This study was approved by the ethics committee. The study was partly funded by the Nycomed Fund of the University Hospital Basel, Switzerland and by Given Imaging Ltd., Yoqneam, Israel).
The authors designed the study, gathered and analyzed the data; the sponsors had no role in design or conduct of the study nor did they review or approve the data.
Patients Men and women above the age of 50 years without symptoms (Indication for screening) or with lower gastrointestinal signs and symptoms and individuals younger than 50 years, minimum 18 years, without symptoms but with a positive family history for colorectal cancer (CRC) (Indication for screening) were considered for this study. Exclusion criteria were CRC in the patient's history, cardiac pacemaker, contraindications for sodium phosphate solution (Colophos®) and risk factors for capsule retention including surgical intestinal anastomosis, Crohn's disease, diverticulitis and radiologically suspected bowel obstruction.
Data collection General characteristic of the patients were assembled, including demographics, family history and recent surgery, as well as bowel habits.
Hypothesis, Aim and End Points Significance was defined as polyps \>5mm in size, with the hypothesis that detection rate on CCE corresponds with colonoscopy. The aim was to evaluate a novel method (colon capsule endoscopy) for performance as a screening tool compared to conventional colonoscopy in asymptomatic patients. The proclaimed benefit would be an increase in acceptance of screening for colorectal cancer and a probable better detection rate of adenoma resp. carcinoma.
The primary endpoint was the number of cancerous lesions and polyps detected on CCE compared to conventional colonoscopy. Secondary endpoints were completeness of the exam completeness, patient acceptance and adherence to preparation regimen.
Colon preparation and Propulsion of the Capsule For colon cleansing we applied our department's standard preparation procedure for conventional colonoscopy including diet and Macrogolum (PEG, Cololyt®; Spirig Pharma, Egerkingen, Switzerland) and added an oral motility agent, Phospho Soda (Colophos®; Spirig Pharma, Egerkingen, Switzerland)-boosters and a rectal suppository that promotes defecation, Table 1. Patients started with a low residual diet three days prior to the PillCam® Colon examination. The following day they were required to adhere to a liquid diet and one day before the examination to a clear liquid diet. The evening before the examination they ingested 2 litres of Cololyt® between 18:00 and 19:30 and continued with another 2 litres the next morning between 7:00 and 8:30. At 11:00 they were given 2 tablets of Domperidon (Motilium®; Janssen-Cilag AG, Baar, Switzerland) 10mg a couple of minutes prior to the PillCam® Colon capsule. Propulsion from stomach to small bowel was verified using real time viewing before giving the first Colophos® booster (45 ml). That we later abandoned (for the remaining 49 patients) due to satisfactory propulsion. If the capsule had not been excreted by 17:00 (3 hours after the first dose) a second dose of 30 ml Colophos® was added. If it still had not been excreted by 19:30, a suppository of Bisacodylum 10 mg (Prontolax®; Streuli Pharma, Uznach, Switzerland) was administered. The patient removed electrodes and recorder-belt at the excretion of the capsule or at 22:00, which ever came first, and continued clear liquid diet until the conventional colonoscopy was performed the following day.
Pillcam Colon Capsule The PillCam® Colon Capsule is 11mm x 31mm in size (Figure 1). It is equipped with two cameras acquiring pictures from both ends of the capsule at a rate of 4 frames per second (2 pictures per second and camera). Compared to the PillCam® Small Bowel capsule the optic is optimized and more than double of the area coverage and depth view are provided. The PillCam® Colon Capsule is automatically activated when it is removed from the package. It enters sleeping mode in order to save energy after approximately 10 minutes and starts transmitting again 1 h 45 min later. It has a total operating time of 8 - 10 hours. During the examination the patient wears a sensor array which is attached to the abdominal skin and a data recorder for storage of the information generated by the ingested capsule. After the examination the data are downloaded into the Given Imaging workstation and a video is generated.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
NA
SINGLE_GROUP
PREVENTION
SINGLE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
Colon capsule endoscopy and colonoscopy
Patients underwent CCE on day 1 and conventional colonoscopy on day 2
Colon capsule endoscopy
The PillCam® Colon Capsule is 11mm x 31mm in size (Figure 1), is equipped with two cameras acquiring pictures from both ends of the capsule at a rate of 4 frames per second (2 pictures per second and camera). The PillCam® Colon Capsule is automatically activated when it is removed from the package. It enters sleeping mode after approximately 10 minutes and starts transmitting again 1 h 45 min later. It has a total operating time of 8 - 10 hours. During the examination the patient wears a sensor array which is attached to the abdominal skin and a data recorder for storage of the information generated by the ingested capsule. After the examination the data are downloaded into the Given Imaging workstation and a video is generated.
Conventional Colonoscopy
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
Colon capsule endoscopy
The PillCam® Colon Capsule is 11mm x 31mm in size (Figure 1), is equipped with two cameras acquiring pictures from both ends of the capsule at a rate of 4 frames per second (2 pictures per second and camera). The PillCam® Colon Capsule is automatically activated when it is removed from the package. It enters sleeping mode after approximately 10 minutes and starts transmitting again 1 h 45 min later. It has a total operating time of 8 - 10 hours. During the examination the patient wears a sensor array which is attached to the abdominal skin and a data recorder for storage of the information generated by the ingested capsule. After the examination the data are downloaded into the Given Imaging workstation and a video is generated.
Conventional Colonoscopy
Other Intervention Names
Discover alternative or legacy names that may be used to describe the listed interventions across different sources.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
* male/female above the age of 50 years without symptoms
* male/female younger than 50 years without symptoms but with a positive family history for colorectal cancer (CRC) (Indication for screening)
Exclusion Criteria
* cardiac pacemaker
* contraindications for sodium phosphate solution (Colophos®)
* risk factors for capsule retention including surgical intestinal anastomosis, Crohn's disease, diverticulitis and radiologically suspected bowel obstruction
18 Years
85 Years
ALL
Yes
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
University Hospital, Basel, Switzerland
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Gastroenterology, University Hospital Basel
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
Julia B Pilz, MD
Role: PRINCIPAL_INVESTIGATOR
University Hospital, Basel, Switzerland
Christoph Beglinger, MD
Role: STUDY_DIRECTOR
University Hospital, Basel, Switzerland
Lukas Degen, MD
Role: STUDY_CHAIR
University Hospital, Basel, Switzerland
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
University Hospital
Basel, Canton of Basel-City, Switzerland
Countries
Review the countries where the study has at least one active or historical site.
References
Explore related publications, articles, or registry entries linked to this study.
Pilz JB, Portmann S, Peter S, Beglinger C, Degen L. Colon Capsule Endoscopy compared to Conventional Colonoscopy under routine screening conditions. BMC Gastroenterol. 2010 Jun 18;10:66. doi: 10.1186/1471-230X-10-66.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
EKBB25407
Identifier Type: -
Identifier Source: org_study_id