Multicenter Evaluation of Safety and Effectiveness of Presbyopic LASIK for Hyperopes
NCT ID: NCT00910403
Last Updated: 2011-05-26
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
COMPLETED
PHASE3
80 participants
INTERVENTIONAL
2009-06-30
2011-05-31
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Intrastromal Presbyopia Correction by Means of a Femtosecond Laser
NCT01025050
A Prospective Safety and Effectiveness Study of a New High Repetition Rate Excimer Laser Using LASIK for the Correction of Ammetropia and Presbyopia
NCT02112968
Presbyopic Supracor Treatment for Near Myopic/Hyperopic Pseudophakic Eyes
NCT01387360
Assessment of Visual and Refractive Results and Rotational Stability of the TECNIS® Eyhance Toric II 1-piece Posterior Chamber Lens in Patients With Astigmatism Undergoing Cataract Surgery
NCT05144308
Prospective Evaluation of the Effectiveness of the Femtosecond Laser-assisted Refractive Astigmatic Keratotomy.
NCT01885780
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
NA
SINGLE_GROUP
TREATMENT
NONE
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
LASIK
Excimer Laser Ablation using LASIK
Other Intervention Names
Discover alternative or legacy names that may be used to describe the listed interventions across different sources.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
* Subjects must read, understand, and sign an Informed Consent Form (ICF).
* Subjects must be willing and able to return for scheduled follow up visits.
* Subjects must be willing to have both eyes treated during the same visit.
* Subjects must have up to +4 diopters (D) of absolute spherical hyperopia (not spherical equivalent), with up to +2.5 D of refractive astigmatism (NOT corneal astigmatism) by manifest subjective refraction in both eyes. The spherical equivalent must be no more than +5.25 D.
* Subjects must have presbyopia as determined by an age-related need for optical aid (\> +1.50 D) for reading with their best distance correction.
* Subjects who are contact lens wearers must have gas permeable (GP) lenses discontinued for at least 3 weeks and soft lenses discontinued for at least 1 week prior to the preoperative evaluation in the eye to be treated. Contact lens wearers who wear their contact lenses for any amount of time between the preoperative baseline examination and the operative visit must not be treated.
* Corneal topography should be normal.
* Subjects who are contact lens wearers must have 2 central keratometry readings and 2 manifest subjective refractions taken preoperatively at least one week apart. The refraction values must not differ by more than 0.50D as defined by manifest refraction spherical equivalent (MRSE). The keratometry values must not differ from the previous values by more than 0.50D in either meridian.
* High contrast, manifest, best spectacle-corrected logMAR distance visual acuity (VA) must be correctable to at least 0.1 (20/25 or 6/7.5) in both eyes.
Exclusion Criteria
* Eyes for which the baseline manifest subjective refraction exhibits a difference of greater than 0.75D in sphere power, or a difference of greater than 0.50D in cylinder power, or a difference in cylinder axis of more than 15 degrees compared to the baseline cycloplegic subjective refraction. For manifest cylinder of less than 0.75D, the difference in cylinder axis will not be taken into consideration.
* Subjects for whom the preoperative assessment of the ocular topography indicates that one or both eyes are not suitable candidates for treatment based upon the suggested computer-simulated treatment plan.
* Any subject who is going to be co-managed by an ophthalmologist or optometrist who is not approved as a Technolas GmbH Excimer laser Investigator.
* Subjects with anterior segment pathology, including dry eye syndrome and cataracts which in the Investigator's opinion, would interfere with best spectacle-corrected VA (BSCVA) or a successful treatment.
* Subjects with evidence of retinal vascular disease.
* Subjects with any residual, recurrent, or active ocular disease, or corneal abnormality that in the Investigator's opinion would interfere with BSCVA or a successful treatment.
* Subjects with signs of keratoconus.
* Subjects with unstable central keratometry readings with irregular mires.
* Subjects who have undergone previous intraocular or corneal surgery of any kind, including any type of excimer laser surgery for either refractive or therapeutic purposes.
* Subjects who have a history of Herpes simplex or Herpes zoster keratitis.
* Subjects who have a history of glaucoma or glaucoma suspect.
* Subjects who are immunocompromised or carrying diagnosis of connective tissue disease, clinically significant atopic disease, diabetes, autoimmune diseases and other acute or chronic illnesses that will increase the risk to the subject or confound the outcomes of this study.
* Subjects taking systemic medications likely to affect wound healing such as corticosteroids or antimetabolites.
* Subjects who are known to be pregnant, lactating, or who plan to become pregnant during the course of the study.
* Subjects with known sensitivity to medications used for standard LASIK.
* Subjects participating in any other ophthalmic clinical trials during this clinical trial.
* Subjects with an ocular muscle disorder including a strabismus or nystagmus, or other disorders affecting fixation.
* Subjects at risk for angle closure.
Procedures:
* Flap complications during the first eye's surgery such as a free cap, partial flap, thin flap, or irregular flap.
* Epithelial defect exceeding 2mm x 2mm in dimension, or clinically significant debris in the interface between the flap and underlying stroma for the first eye.
* Severe blepharospasm in the first eye that may have prevented or impeded the completion of the keratectomy and/or the laser ablation procedure.
* Poor subject cooperation with instructions for the first eye's surgery and/or poor subject fixation on the laser fixation target.
* Aborted LASIK procedure in the first eye or PRK or Epi-LASIK was performed in the first eye because LASIK was not possible.
18 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Technolas Perfect Vision GmbH
INDUSTRY
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Technolas PerfectVision
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
Jean-Jacques Chaubard, Dr.
Role: PRINCIPAL_INVESTIGATOR
VisionFuture / Nice
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Dr. Roure
Nice, , France
Vision Future Nice
Nice, , France
Clinique de la Vision Paris
Paris, , France
Instituo Oftalmologico Casteanera
Barcelona, , Spain
Countries
Review the countries where the study has at least one active or historical site.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
0901
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.