Multicenter Evaluation of Safety and Effectiveness of Presbyopic LASIK for Hyperopes

NCT ID: NCT00910403

Last Updated: 2011-05-26

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

COMPLETED

Clinical Phase

PHASE3

Total Enrollment

80 participants

Study Classification

INTERVENTIONAL

Study Start Date

2009-06-30

Study Completion Date

2011-05-31

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

The Presbyopia Algorithm subject to this study has been specifically developed to prospectively generate a treatment file for the Technolas 217z100 laser that will provide Presbyopia correction among eyes with primary hyperopia or hyperopic astigmatism (distance correction). The treatment algorithm provides a bilateral, multifocal ablation with a center near addition, thereby allowing good focus over a range of object distances.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Presbyopia Hyperopia

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Allocation Method

NA

Intervention Model

SINGLE_GROUP

Primary Study Purpose

TREATMENT

Blinding Strategy

NONE

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

LASIK

Excimer Laser Ablation using LASIK

Intervention Type PROCEDURE

Other Intervention Names

Discover alternative or legacy names that may be used to describe the listed interventions across different sources.

PresbyLASIK

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

* Subjects must be at least 18 years old
* Subjects must read, understand, and sign an Informed Consent Form (ICF).
* Subjects must be willing and able to return for scheduled follow up visits.
* Subjects must be willing to have both eyes treated during the same visit.
* Subjects must have up to +4 diopters (D) of absolute spherical hyperopia (not spherical equivalent), with up to +2.5 D of refractive astigmatism (NOT corneal astigmatism) by manifest subjective refraction in both eyes. The spherical equivalent must be no more than +5.25 D.
* Subjects must have presbyopia as determined by an age-related need for optical aid (\> +1.50 D) for reading with their best distance correction.
* Subjects who are contact lens wearers must have gas permeable (GP) lenses discontinued for at least 3 weeks and soft lenses discontinued for at least 1 week prior to the preoperative evaluation in the eye to be treated. Contact lens wearers who wear their contact lenses for any amount of time between the preoperative baseline examination and the operative visit must not be treated.
* Corneal topography should be normal.
* Subjects who are contact lens wearers must have 2 central keratometry readings and 2 manifest subjective refractions taken preoperatively at least one week apart. The refraction values must not differ by more than 0.50D as defined by manifest refraction spherical equivalent (MRSE). The keratometry values must not differ from the previous values by more than 0.50D in either meridian.
* High contrast, manifest, best spectacle-corrected logMAR distance visual acuity (VA) must be correctable to at least 0.1 (20/25 or 6/7.5) in both eyes.

Exclusion Criteria

* Subjects for whom the combination of their baseline corneal thickness and the planned operative parameters for the LASIK procedure would result in less than 250 microns of remaining posterior corneal thickness below the flap postoperatively.
* Eyes for which the baseline manifest subjective refraction exhibits a difference of greater than 0.75D in sphere power, or a difference of greater than 0.50D in cylinder power, or a difference in cylinder axis of more than 15 degrees compared to the baseline cycloplegic subjective refraction. For manifest cylinder of less than 0.75D, the difference in cylinder axis will not be taken into consideration.
* Subjects for whom the preoperative assessment of the ocular topography indicates that one or both eyes are not suitable candidates for treatment based upon the suggested computer-simulated treatment plan.
* Any subject who is going to be co-managed by an ophthalmologist or optometrist who is not approved as a Technolas GmbH Excimer laser Investigator.
* Subjects with anterior segment pathology, including dry eye syndrome and cataracts which in the Investigator's opinion, would interfere with best spectacle-corrected VA (BSCVA) or a successful treatment.
* Subjects with evidence of retinal vascular disease.
* Subjects with any residual, recurrent, or active ocular disease, or corneal abnormality that in the Investigator's opinion would interfere with BSCVA or a successful treatment.
* Subjects with signs of keratoconus.
* Subjects with unstable central keratometry readings with irregular mires.
* Subjects who have undergone previous intraocular or corneal surgery of any kind, including any type of excimer laser surgery for either refractive or therapeutic purposes.
* Subjects who have a history of Herpes simplex or Herpes zoster keratitis.
* Subjects who have a history of glaucoma or glaucoma suspect.
* Subjects who are immunocompromised or carrying diagnosis of connective tissue disease, clinically significant atopic disease, diabetes, autoimmune diseases and other acute or chronic illnesses that will increase the risk to the subject or confound the outcomes of this study.
* Subjects taking systemic medications likely to affect wound healing such as corticosteroids or antimetabolites.
* Subjects who are known to be pregnant, lactating, or who plan to become pregnant during the course of the study.
* Subjects with known sensitivity to medications used for standard LASIK.
* Subjects participating in any other ophthalmic clinical trials during this clinical trial.
* Subjects with an ocular muscle disorder including a strabismus or nystagmus, or other disorders affecting fixation.
* Subjects at risk for angle closure.


Procedures:

* Flap complications during the first eye's surgery such as a free cap, partial flap, thin flap, or irregular flap.
* Epithelial defect exceeding 2mm x 2mm in dimension, or clinically significant debris in the interface between the flap and underlying stroma for the first eye.
* Severe blepharospasm in the first eye that may have prevented or impeded the completion of the keratectomy and/or the laser ablation procedure.
* Poor subject cooperation with instructions for the first eye's surgery and/or poor subject fixation on the laser fixation target.
* Aborted LASIK procedure in the first eye or PRK or Epi-LASIK was performed in the first eye because LASIK was not possible.
Minimum Eligible Age

18 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

No

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

Technolas Perfect Vision GmbH

INDUSTRY

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Technolas PerfectVision

Principal Investigators

Learn about the lead researchers overseeing the trial and their institutional affiliations.

Jean-Jacques Chaubard, Dr.

Role: PRINCIPAL_INVESTIGATOR

VisionFuture / Nice

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

Dr. Roure

Nice, , France

Site Status

Vision Future Nice

Nice, , France

Site Status

Clinique de la Vision Paris

Paris, , France

Site Status

Instituo Oftalmologico Casteanera

Barcelona, , Spain

Site Status

Countries

Review the countries where the study has at least one active or historical site.

France Spain

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

0901

Identifier Type: -

Identifier Source: org_study_id

More Related Trials

Additional clinical trials that may be relevant based on similarity analysis.

ICL and LASIK for Hyperopic Astigmatism
NCT06742541 COMPLETED EARLY_PHASE1
Long-term LASIK Follow up Study
NCT01695642 COMPLETED