Wavefront-guided LASIK for Monovision Treatment of Myopic Subjects With Presbyopia
NCT ID: NCT04075591
Last Updated: 2025-07-23
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
COMPLETED
NA
219 participants
INTERVENTIONAL
2019-09-24
2025-06-25
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Clinical Investigation iDesign System With 1.3-PRESBY Treatment and STAR S4 IR™ Excimer Laser System
NCT02806726
Safety and Effectiveness of Wavefront-Guided LASIK Correction of Hyperopic Refractive Errors
NCT01675479
Evaluation of Outcomes Using the AMO Advanced Customvue™ iLasik Procedure
NCT01061294
Safety and Effectiveness of Wavefront-guided LASIK for the Correction of Mixed Astigmatism
NCT01675492
An Evaluation of Outcomes Following Wavefront Optimized or Wavefront Guided Lasik Procedure in Low to Moderate Myopic Patients
NCT01173198
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
NA
SINGLE_GROUP
OTHER
NONE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
Wavefront-guided Lasik Monovision Treatment
Wavefront-guided LASIK monovision treatment of myopic subjects with presbyopia using the STAR S4 IR® Excimer laser System with the iDesign Refractive Studio.
iDesign Refractive Studio with STAR S4 IR® Excimer laser System
Surgeons will perform wavefront-guided monovision LASIK for the treatment of myopic subjects with presbyopia based upon measurements obtained with an iDesign Refractive Studio.
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
iDesign Refractive Studio with STAR S4 IR® Excimer laser System
Surgeons will perform wavefront-guided monovision LASIK for the treatment of myopic subjects with presbyopia based upon measurements obtained with an iDesign Refractive Studio.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
2. At least 40 years of age at enrollment (date informed consent signed).
3. The refractive error of both subject's eyes, based on the iDesign refraction selected for treatment ("4.0 mm Rx calc" at 12.5 mm), must be myopic with or without astigmatism up to -6.00 D spherical equivalent (SE), with cylinder up to -3.00 D and minimum pre-operative myopia in their non-dominant eye at least as great as their targeted myopic retention.
4. At least one eye must require a myopic treatment.
5. Anticipated stromal bed thickness of at least 250 microns based on preoperative central corneal pachymetry minus the maximum treatment depth to be ablated (as calculated by the iDesign plus the intended flap thickness).
6. Distance Best Spectacle Corrected Visual Acuity (BSCVA) of 20/20 or better.
7. Require an add power of +1.25 D or more but not greater than +2.00 D at 40 cm.
8. Less than or equal to ±0.50 D difference between cycloplegic and manifest refraction sphere.
9. A stable refractive error (based on a previous exam, medical records, lensometry, or prescription that is at least 12 months prior to the preoperative manifest refraction), as defined by a change of less than or equal to
* 0.50 D in MRSE (sphere and cylinder).
10. Subjects with a history of contact lens wear within the last 4 weeks must discontinue lens wear in order to demonstrate refractive stability according to the following (refractive stability is defined as a change of not more than 0.50 D in manifest refraction sphere and cylinder as well as mean keratometry between measurements): After the Informed Consent process has been completed and subjects are enrolled in the study:
* Rigid or extended wear contact lenses (toric or spherical) must be removed for at least 3 weeks and soft contact lenses (toric or spherical) for at least 2 weeks prior to the first refraction used to establish stability.
* After abstaining from contact lens wear for designated time, two consecutive manifest refractions and keratometric readings must be conducted at least 7 days apart
* I If the subject/eye meets the refractive stability criteria, contact lens wear is not permitted for 2 weeks prior to surgery except as required to test monovision acceptance as described below in the Study Procedures, Contact Lens Trial section NOTE: Refractive stability needs to be confirmed only once during preoperative assessment
11. Agreement between manifest refraction (adjusted for optical infinity) and iDesign System refraction chosen for treatment, as follows:
* Spherical Equivalent: magnitude of the difference is less than 0.625 D.
* Cylinder: magnitude of the difference is less than or equal to 0.5 D.
* Cylinder Axis Tolerance: If either the manifest cylinder entered into the iDesign System or the iDesign cylinder selected for treatment is less than 0.5 D, there is no requirement for axis agreement. When both cylinders have a magnitude of at least 0.5 D, the axis tolerance as determined by the iDesign system is linearly reduced from 15 degrees (0.5 D) to 7.5 degrees (7.0 D) based on the average magnitude of both cylinders. Note: If the axis tolerance is not in the calculated range, the iDesign system will produce a warning and this exam may not be used for treatment planning.
12. Willing and capable of complying with follow-up examinations for the duration of the study.
Exclusion Criteria
Note: Women who were pregnant or nursing may not be enrolled until 6 months after either delivery or have stopped nursing and there is documented refractive stability.
2. Concurrent use of systemic (including inhaled) medications that may impair healing, including but not limited to: antimetabolites, isotretinoin (Accutane®) within 6 months of treatment, and amiodarone hydrochloride (Cordarone®) within 12 months of treatment. NOTE: The use of inhaled or systemic corticosteroids, whether chronic or acute, within the past 6 months is deemed to adversely affect healing and subjects using such medications are specifically excluded from eligibility.
3. History of any of the following medical conditions, or any other condition that could affect wound healing: collagen vascular disease, autoimmune disease, immunodeficiency diseases, ocular herpes zoster or herpes simplex, endocrine disorders (including, but not limited to unstable thyroid disorders and diabetes), lupus, and rheumatoid arthritis.
NOTE: The presence of diabetes (either type 1 or 2), regardless of disease duration, severity, or control, will specifically exclude subjects from eligibility.
4. Subjects with a cardiac pacemaker, implanted defibrillator or other implanted electronic device.
5. History of prior intraocular or corneal surgery (including cataract extraction), active ophthalmic disease or abnormality (including, but not limited to, symptomatic blepharitis, recurrent corneal erosion, dry eye syndrome, neovascularization \> 1 mm from limbus), retinal detachment/repair, clinically significant lens opacity, clinical evidence of trauma, corneal opacity within the central 9 mm and visible on topography, prior strabismus surgery, strabismus, or at risk for developing strabismus, or with evidence of glaucoma or propensity for narrow angle glaucoma or suspected glaucoma.
NOTE: Subjects with glaucoma, regardless of medication regimen or control, or an IOP greater than 21 mmHg at screening, are specifically excluded from eligibility.
6. Evidence of keratoconus, corneal dystrophy or irregularity, or abnormal topography.
7. Known sensitivity or inappropriate responsiveness to any of the medications used in the postoperative course.
8. Intolerance to monovision correction based on questionnaire responses to contact lens trial (refer to section Study Procedures, Contact Lens Trial below).
9. Concurrent participation in any other clinical trial, or participation in any other clinical trial within the last 14 days.
40 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
AMO Development, LLC
INDUSTRY
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
AMO Development, LLC Clinical Trial
Role: STUDY_DIRECTOR
AMO Development, LLC
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Maloney Vision Institute
Los Angeles, California, United States
Kraff Eye Institute
Chicago, Illinois, United States
Center for Sight
Las Vegas, Nevada, United States
Coleman Vision
Albuquerque, New Mexico, United States
Vance Thompson Vision
Sioux Falls, South Dakota, United States
Loden Vision Centers
Goodlettsville, Tennessee, United States
Berkeley Eye Institute, P.A.
Houston, Texas, United States
Texas Eye & Laser Center
Hurst, Texas, United States
Utah Eye Center
Ogden, Utah, United States
The Eye Center
Fairfax, Virginia, United States
Countries
Review the countries where the study has at least one active or historical site.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
STAR-122-MVPM
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.