Wavefront-guided LASIK for Monovision Treatment of Myopic Subjects With Presbyopia

NCT ID: NCT04075591

Last Updated: 2025-07-23

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

COMPLETED

Clinical Phase

NA

Total Enrollment

219 participants

Study Classification

INTERVENTIONAL

Study Start Date

2019-09-24

Study Completion Date

2025-06-25

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

This study will be a 12-month, prospective, multicenter, open-label, non-comparative, non-randomized clinical investigation conducted at 8 to 14 sites. A total of 383 subjects will be enrolled to achieve approximately 268 treated subjects, resulting in at least 241 evaluable subjects at the point of refractive stability. After signing the informed consent, subjects meeting all inclusion and exclusion criteria in both eyes may be scheduled for surgery. The follow-up visit schedule will be the same for each operative eye.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Refractive Error

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Allocation Method

NA

Intervention Model

SINGLE_GROUP

wavefront-guided LASIK monovision treatment
Primary Study Purpose

OTHER

Blinding Strategy

NONE

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

Wavefront-guided Lasik Monovision Treatment

Wavefront-guided LASIK monovision treatment of myopic subjects with presbyopia using the STAR S4 IR® Excimer laser System with the iDesign Refractive Studio.

Group Type EXPERIMENTAL

iDesign Refractive Studio with STAR S4 IR® Excimer laser System

Intervention Type DEVICE

Surgeons will perform wavefront-guided monovision LASIK for the treatment of myopic subjects with presbyopia based upon measurements obtained with an iDesign Refractive Studio.

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

iDesign Refractive Studio with STAR S4 IR® Excimer laser System

Surgeons will perform wavefront-guided monovision LASIK for the treatment of myopic subjects with presbyopia based upon measurements obtained with an iDesign Refractive Studio.

Intervention Type DEVICE

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

1. Signed informed consent and HIPAA authorization.
2. At least 40 years of age at enrollment (date informed consent signed).
3. The refractive error of both subject's eyes, based on the iDesign refraction selected for treatment ("4.0 mm Rx calc" at 12.5 mm), must be myopic with or without astigmatism up to -6.00 D spherical equivalent (SE), with cylinder up to -3.00 D and minimum pre-operative myopia in their non-dominant eye at least as great as their targeted myopic retention.
4. At least one eye must require a myopic treatment.
5. Anticipated stromal bed thickness of at least 250 microns based on preoperative central corneal pachymetry minus the maximum treatment depth to be ablated (as calculated by the iDesign plus the intended flap thickness).
6. Distance Best Spectacle Corrected Visual Acuity (BSCVA) of 20/20 or better.
7. Require an add power of +1.25 D or more but not greater than +2.00 D at 40 cm.
8. Less than or equal to ±0.50 D difference between cycloplegic and manifest refraction sphere.
9. A stable refractive error (based on a previous exam, medical records, lensometry, or prescription that is at least 12 months prior to the preoperative manifest refraction), as defined by a change of less than or equal to

* 0.50 D in MRSE (sphere and cylinder).
10. Subjects with a history of contact lens wear within the last 4 weeks must discontinue lens wear in order to demonstrate refractive stability according to the following (refractive stability is defined as a change of not more than 0.50 D in manifest refraction sphere and cylinder as well as mean keratometry between measurements): After the Informed Consent process has been completed and subjects are enrolled in the study:

* Rigid or extended wear contact lenses (toric or spherical) must be removed for at least 3 weeks and soft contact lenses (toric or spherical) for at least 2 weeks prior to the first refraction used to establish stability.
* After abstaining from contact lens wear for designated time, two consecutive manifest refractions and keratometric readings must be conducted at least 7 days apart
* I If the subject/eye meets the refractive stability criteria, contact lens wear is not permitted for 2 weeks prior to surgery except as required to test monovision acceptance as described below in the Study Procedures, Contact Lens Trial section NOTE: Refractive stability needs to be confirmed only once during preoperative assessment
11. Agreement between manifest refraction (adjusted for optical infinity) and iDesign System refraction chosen for treatment, as follows:

* Spherical Equivalent: magnitude of the difference is less than 0.625 D.
* Cylinder: magnitude of the difference is less than or equal to 0.5 D.
* Cylinder Axis Tolerance: If either the manifest cylinder entered into the iDesign System or the iDesign cylinder selected for treatment is less than 0.5 D, there is no requirement for axis agreement. When both cylinders have a magnitude of at least 0.5 D, the axis tolerance as determined by the iDesign system is linearly reduced from 15 degrees (0.5 D) to 7.5 degrees (7.0 D) based on the average magnitude of both cylinders. Note: If the axis tolerance is not in the calculated range, the iDesign system will produce a warning and this exam may not be used for treatment planning.
12. Willing and capable of complying with follow-up examinations for the duration of the study.

Exclusion Criteria

1. Women who are pregnant, breast-feeding, or intend to become pregnant during the study.

Note: Women who were pregnant or nursing may not be enrolled until 6 months after either delivery or have stopped nursing and there is documented refractive stability.
2. Concurrent use of systemic (including inhaled) medications that may impair healing, including but not limited to: antimetabolites, isotretinoin (Accutane®) within 6 months of treatment, and amiodarone hydrochloride (Cordarone®) within 12 months of treatment. NOTE: The use of inhaled or systemic corticosteroids, whether chronic or acute, within the past 6 months is deemed to adversely affect healing and subjects using such medications are specifically excluded from eligibility.
3. History of any of the following medical conditions, or any other condition that could affect wound healing: collagen vascular disease, autoimmune disease, immunodeficiency diseases, ocular herpes zoster or herpes simplex, endocrine disorders (including, but not limited to unstable thyroid disorders and diabetes), lupus, and rheumatoid arthritis.

NOTE: The presence of diabetes (either type 1 or 2), regardless of disease duration, severity, or control, will specifically exclude subjects from eligibility.
4. Subjects with a cardiac pacemaker, implanted defibrillator or other implanted electronic device.
5. History of prior intraocular or corneal surgery (including cataract extraction), active ophthalmic disease or abnormality (including, but not limited to, symptomatic blepharitis, recurrent corneal erosion, dry eye syndrome, neovascularization \> 1 mm from limbus), retinal detachment/repair, clinically significant lens opacity, clinical evidence of trauma, corneal opacity within the central 9 mm and visible on topography, prior strabismus surgery, strabismus, or at risk for developing strabismus, or with evidence of glaucoma or propensity for narrow angle glaucoma or suspected glaucoma.

NOTE: Subjects with glaucoma, regardless of medication regimen or control, or an IOP greater than 21 mmHg at screening, are specifically excluded from eligibility.
6. Evidence of keratoconus, corneal dystrophy or irregularity, or abnormal topography.
7. Known sensitivity or inappropriate responsiveness to any of the medications used in the postoperative course.
8. Intolerance to monovision correction based on questionnaire responses to contact lens trial (refer to section Study Procedures, Contact Lens Trial below).
9. Concurrent participation in any other clinical trial, or participation in any other clinical trial within the last 14 days.
Minimum Eligible Age

40 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

No

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

AMO Development, LLC

INDUSTRY

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Responsibility Role SPONSOR

Principal Investigators

Learn about the lead researchers overseeing the trial and their institutional affiliations.

AMO Development, LLC Clinical Trial

Role: STUDY_DIRECTOR

AMO Development, LLC

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

Maloney Vision Institute

Los Angeles, California, United States

Site Status

Kraff Eye Institute

Chicago, Illinois, United States

Site Status

Center for Sight

Las Vegas, Nevada, United States

Site Status

Coleman Vision

Albuquerque, New Mexico, United States

Site Status

Vance Thompson Vision

Sioux Falls, South Dakota, United States

Site Status

Loden Vision Centers

Goodlettsville, Tennessee, United States

Site Status

Berkeley Eye Institute, P.A.

Houston, Texas, United States

Site Status

Texas Eye & Laser Center

Hurst, Texas, United States

Site Status

Utah Eye Center

Ogden, Utah, United States

Site Status

The Eye Center

Fairfax, Virginia, United States

Site Status

Countries

Review the countries where the study has at least one active or historical site.

United States

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

STAR-122-MVPM

Identifier Type: -

Identifier Source: org_study_id

More Related Trials

Additional clinical trials that may be relevant based on similarity analysis.

Long-term LASIK Follow up Study
NCT01695642 COMPLETED