Safety and Effectiveness of the TENEO 317 Model 2 (1.28 US) Excimer Laser for Laser In Situ Keratomileusis (LASIK) Surgery to Treat Hyperopia With or Without Astigmatism

NCT ID: NCT05264623

Last Updated: 2026-01-23

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

ACTIVE_NOT_RECRUITING

Clinical Phase

NA

Total Enrollment

140 participants

Study Classification

INTERVENTIONAL

Study Start Date

2022-11-15

Study Completion Date

2026-11-20

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

This will be a multicenter, prospective, open label, non-randomized, single arm 12 month study, evaluating the safety and effectiveness of the TECHNOLAS TENEO 317 Model 2 (Software version "1.28 US") excimer laser when used in LASIK surgery to treat hyperopia with or without hyperopic astigmatism. Both eyes of a subject may be enrolled so long as both eyes meet all inclusion/exclusion requirements. Analysis of the primary effectiveness endpoint will be completed at refractive stability.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Hyperopia

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Allocation Method

NA

Intervention Model

SINGLE_GROUP

Primary Study Purpose

TREATMENT

Blinding Strategy

NONE

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

TENEO 317 Model 2 excimer laser

Group Type EXPERIMENTAL

TENEO 317 Model 2 excimer laser

Intervention Type DEVICE

TENEO 317 Model 2 excimer laser use for refractive surgery

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

TENEO 317 Model 2 excimer laser

TENEO 317 Model 2 excimer laser use for refractive surgery

Intervention Type DEVICE

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

1. Subjects 22 years of age or older at the time of the pre-operative examination.
2. Manifest, distance corrected visual acuity (CDVA) 20/25 (logMAR 0.10) or better in an operative eye
3. Pre-operative refractive error of hyperopia with spherical component of 0.00 D to +4.00 D with or without cylinder up to +2.00 D, with MRSE of ≥ 0.375 D and ≤ +5.00 D based on the manifest refraction in thestudy eye(s). This would exclude eyes with cylinder-only corrections \< +0.75D and sphere-only corrections \< +0.375D)
4. Difficulty maintaining uncorrected distance visual acuity (UDVA) of 20/40 or better, as evidenced by need for constant contact lens or spectacle wear.
5. Difference between manifest refractive and cycloplegic spherical equivalent ≤ 0.75 D, difference between manifest and cycloplegic cylinder ≤ ± 0.50 D and difference between manifest and cycloplegic cylinder axis ≤ ± 15 degrees.
6. Stable refraction (i.e., a change of ≤ ± 0.50 D in MRSE) for a minimum of 12 months prior to surgery, as verified by consecutive refractions, medical records, or prescription history.
7. Agree to discontinue use of contact lenses for at least 2 weeks (for rigid or toric lenses) or 3 days (for soft contact lenses) prior to the first refraction used to establish stability and through the day of surgery.
8. All contact lens wearers must demonstrate a stable refraction in an eye to be treated, as follows: two consecutive examinations at least 1 week apart within ± 0.50 D manifest refractive spherical equivalent and within ± 15 degrees cylinder axis.
9. Agree to emmetropia correction for each treated eye.
10. Anticipated postoperative stromal bed thickness of at least 250 microns.
11. Can lie flat without difficulty.
12. Willing and able to read, understand, and sign a written informed consent form (ICF).
13. Willing and able to comply with the schedule for all post-surgery follow-up visits.

Exclusion Criteria

1. Acute or chronic disease or illness that would increase operative risk or confound the results of the study (e.g., dry eye disease, cataract, glaucoma, immuno-compromised, rheumatoid arthritis, clinically significant atopic disease, acne rosacea, autoimmune disease, endocrine disorders, lupus, systemic connective tissue disease, diabetes, or severe atopic disease).
2. Use of medications by any administration route that may increase risk to the subject or may confound the outcome of the study, including those known to affect wound healing (e.g., systemic corticosteroids, antimetabolites).
3. Ocular conditions, other than hyperopia with or without astigmatism that may predispose the subject to future complications including but not limited to:

1. Evidence or history of retinal vascular disease
2. Evidence or history of active or inactive corneal disease or infection (e.g., recurrent corneal erosion syndrome, herpes simplex or herpes zoster keratitis) in either eye.
3. Evidence or history of glaucoma or glaucoma suspect (IOP \> 24mmHg) by exam findings and/or family history
4. Previous intraocular or corneal surgery in an eye considered for eligibility that might confound the outcome of the study or increase the risk to the subject.
5. An increased risk for developing strabismus post-treatment or an ocular muscle disorder (e.g., strabismus or nystagmus) affecting fixation.
6. Known sensitivity to any study medications (e.g., used during LASIK procedure and postoperative care).
7. Have central corneal scars affecting visual acuity.
8. Have mixed astigmatism.
9. Presence of keratoconus, keratoconus suspect, subclinical or forme fruste keratoconus, corneal dystrophy, or other corneal irregularity (e.g., irregular astigmatism) or abnormal corneal topography
10. Presence of visually significant or progressive cataract in an eye considered for eligibility.
11. Actively taking medications contraindicated with LASIK such as isotretinoin (Accutane) or amiodarone hydrochloride (Cordarone).
12. Have a cardiac pacemaker, implanted defibrillator, or other implanted electronic device.
13. Pregnant, lactating, or subjects who plan to become pregnant during the course of the study.
14. Are participating in any other trial within 30 days of screening or during this clinical trial.
15. Eyes with mesopic pupil size \> 7.0 mm.
16. Have a Schirmer's pre-operative test without anesthesia \< 4 mm after 5 minutes
Minimum Eligible Age

22 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

No

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

Bausch & Lomb Incorporated

INDUSTRY

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Responsibility Role SPONSOR

Principal Investigators

Learn about the lead researchers overseeing the trial and their institutional affiliations.

Rosangela Nolasco

Role: STUDY_DIRECTOR

Bausch & Lomb Incorporated

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

Site 113

Newport Beach, California, United States

Site Status

Site 111

Fort Myers, Florida, United States

Site Status

Site 101

Bloomington, Minnesota, United States

Site Status

Site 104

Saint Louis Park, Minnesota, United States

Site Status

Site 103

Omaha, Nebraska, United States

Site Status

Site 102

Amherst, New York, United States

Site Status

Site 112

Pittsburgh, Pennsylvania, United States

Site Status

Site 108

Sioux Falls, South Dakota, United States

Site Status

Site 106

Cedar Park, Texas, United States

Site Status

Countries

Review the countries where the study has at least one active or historical site.

United States

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

906

Identifier Type: -

Identifier Source: org_study_id

More Related Trials

Additional clinical trials that may be relevant based on similarity analysis.

Long-term LASIK Follow up Study
NCT01695642 COMPLETED
LASIK Using Contoura With Phorcides vs. iDesign
NCT07128316 ACTIVE_NOT_RECRUITING NA