A Prospective Safety and Effectiveness Study of a New High Repetition Rate Excimer Laser Using LASIK for the Correction of Ammetropia and Presbyopia

NCT ID: NCT02112968

Last Updated: 2014-11-20

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

UNKNOWN

Clinical Phase

PHASE4

Total Enrollment

97 participants

Study Classification

INTERVENTIONAL

Study Start Date

2014-12-31

Study Completion Date

2017-05-31

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

This clinical study has been planned to evaluate the safety and effectiveness of common treatment algorithms using 500 Hz laser repetition rate for the correction of Ammetropia and Presbyopia

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

This clinical study has been planned to evaluate the safety and effectiveness of the excimer laser treatment algorithms Proscan, Zyoptix and Supracor of the 500 Hz laser system for ametropia and/or presbyopia when performed on the cornea of virgin eyes.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Myopia Hyperopia Presbyopia

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Allocation Method

NON_RANDOMIZED

Intervention Model

SINGLE_GROUP

Primary Study Purpose

TREATMENT

Blinding Strategy

NONE

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

Proscan

Ametropia Lasik treatment of virgin eyes.

Group Type EXPERIMENTAL

Proscan

Intervention Type PROCEDURE

One device (500 Hz Excimer Laser) with three interventions (Proscan, Zyoptix and Supracor as algorithms)

Zyoptix

Wavefront based ametropia Lasik treatment of virgin eyes.

Group Type EXPERIMENTAL

Zyoptix

Intervention Type PROCEDURE

One device (500 Hz Excimer Laser) with three interventions (Proscan, Zyoptix and Supracor as algorithms)

Supracor

Ametropia Lasik treatment of virgin eyes with presbyopia.

Group Type EXPERIMENTAL

Supracor

Intervention Type PROCEDURE

One device (500 Hz Excimer Laser) with three interventions (Proscan, Zyoptix and Supracor as algorithms)

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

Proscan

One device (500 Hz Excimer Laser) with three interventions (Proscan, Zyoptix and Supracor as algorithms)

Intervention Type PROCEDURE

Zyoptix

One device (500 Hz Excimer Laser) with three interventions (Proscan, Zyoptix and Supracor as algorithms)

Intervention Type PROCEDURE

Supracor

One device (500 Hz Excimer Laser) with three interventions (Proscan, Zyoptix and Supracor as algorithms)

Intervention Type PROCEDURE

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

* Subjects have to be at least 18 years of age.
* Subjects have to be able to read, understand, and sign a statement of Informed Consent (be given a copy of the signed Informed Consent Form (ICF).
* Subjects have to be willing and able to return for scheduled follow-up examinations for up to 6 respectively 12 months after surgery.
* For Proscan and Zyoptix Treatments the myopic subjects require a sphere between -0.5 D up to a maximum sphere of -10.0 D. If the patient has a refractive astigmatism to be treated, this must be between -0.5 D up to -4.0 D (not corneal astigmatism) as expressed in spectacle minus cylinder form (by manifest subjective refraction). Overall the SE for myopes must be no more than -12.0 D.
* The Hyperopic subjects require a sphere between +0.5 D up to a maximum sphere of +4.0 D. If the patient has a refractive astigmatism to be treated, this must be between +0.5 D up to +4.0 D (not corneal astigmatism) as expressed in spectacle plus cylinder form (by manifest subjective refraction). Overall the SE for hyperopes must be no more than +6.0 D.
* Subjects who are contact lens wearers must have gas permeable lenses discontinued for at least 3 weeks and soft lenses discontinued for at least 1 week prior to the pre-operative evaluation in the eye to be treated.
* Corneal topography should be qualified.
* Subjects who are contact lens wearers must have two (2) central keratometry readings and two (2) manifest subjective refractions taken pre-operatively at least one week apart. The refraction values must not differ by more than 0.50 D as defined by manifest refraction spherical equivalent (MRSE). The keratometry values must not differ from the previous values by more than 0.50 D in either meridian.
* High contrast, manifest, best spectacle-corrected distance visual acuity correctable binocular to at least 1.0 (Snellen 20/20 or 6/6) and monocular to at least 0.8 (Snel-len 20/25 or 6/7.5). In case of a monocular surgery the eye which should not be treated must have a best corrected distance visual acuity of at least 0.8 (Snellen 20/25 or 6/7.5).
* For treatments with the SUPRACOR presbyopic algorithm, subjects have to be at least 45 years old and no more than 85 years.
* For treatments with the SUPRACOR presbyopic algorithm, subjects must have presbyopia as determined by an age-related need for optical aid (\> +1.50 D) for reading with their best distance correction and been screened successfully for acceptance of the SUPRACOR simulation.
* For treatments with the SUPRACOR presbyopic algorithm, subjects must been screened successfully for acceptance of the SUPRACOR simulation
* For treatments with the SUPRACOR presbyopic algorithm, Myopic subjects must have up to -7.0 diopters (D) of absolute spherical myopia (not spherical equivalent), with up to -4.0 D of refractive astigmatism (NOT corneal astigmatism) by manifest subjective refraction. The spherical equivalent and must be no more than -9.0 D.
* Hyperopic subjects must have up to +4 diopters (D) of absolute spherical hyperopia (not spherical equivalent), with up to +2.5 D of refractive astigmatism (NOT corneal astigmatism) by manifest subjective refraction in both eyes. The spherical equivalent must be no more than +5.25 D.
* Mesopic pupil size measured with the Zywave II WaveFront Aberrometer must be \< 7.0 mm and photopic pupil size measured with the Orbscan II/ IIz must be \> 2.9 mm.
* For treatments with the Zyoptix algorithm, the high-order-aberration must be at least 0.35µm.

Exclusion Criteria

* Subjects for whom the combination of their baseline corneal thickness and the planned operative parameters for the LASIK procedure would result in less than 250 microns of remaining posterior corneal thickness below the flap postoperatively.
* Hyperopic eyes for which the baseline manifest subjective refraction exhibits a difference of greater than ± 0.75 D in sphere power, or a difference of greater than ± 0.50 D in cylinder power, or a difference in cylinder axis of more than 15 degrees compared to the baseline cycloplegic subjective refraction. For manifest cylinder of less than ±0.75 D, the difference in cylinder axis would not be taken into consideration.
* Any subject who is going to be co-managed by an ophthalmologist or optometrist who were not approved as a Technolas Perfect Vision Investigator.
* Subjects with anterior segment pathology, including dry eye syndrome and cataracts, which in the Investigator's opinion would interfere with best spectacle-corrected visual acuity or a successful treatment.
* Subjects with evidence of retinal vascular disease.
* Subjects with any residual, recurrent, or active ocular disease, or corneal abnormality that in the Investigator's opinion would interfere with BSCVA or a successful treatment.
* Subjects with signs of keratoconus.
* Subjects with unstable central keratometry readings with irregular mires.
* Subjects who had previous intraocular or corneal surgery of any kind, including any type of Excimer laser surgery for either refractive or therapeutic purposes.
* Subjects who have a history of Herpes simplex or Herpes zoster keratitis.
* Subject who have a history of glaucoma or glaucoma suspect.
* Subjects with corneal edema, or increased IOP \> 22mmHg.
* Subjects at risk for angle closure.
* Subjects immunocompromised or carrying diagnosis of connective tissue disease, clinically significant atopic disease, diabetes, autoimmune diseases and other acute or chronic illnesses that will increase the risk to the subject or confound the outcomes of this study.
* Subject taking systemic medications likely to affect wound healing such as corticosteroids or antimetabolites.
* Subjects who are known to be pregnant, lactating, or who plans to become pregnant over the course of the study.
* Subjects with known sensitivity to medications used for standard LASIK.
* Subjects participating in any other ophthalmic clinical trials during this clinical study.
* Subjects with an ocular muscle disorder including a strabismus or nystagmus, or other disorders affecting fixation.
* Subjects with cognitive impairments or other vulnerable persons.
* Subjects with anterior or posterior synechiae.
Minimum Eligible Age

18 Years

Maximum Eligible Age

85 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

No

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

Technolas Perfect Vision GmbH

INDUSTRY

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Responsibility Role SPONSOR

Principal Investigators

Learn about the lead researchers overseeing the trial and their institutional affiliations.

Pavel Stodulka, M.D.

Role: PRINCIPAL_INVESTIGATOR

Gemini ocni centrum

Central Contacts

Reach out to these primary contacts for questions about participation or study logistics.

Melanie Doerner

Role: CONTACT

+49 89 94004130

Patrick Schmidt

Role: CONTACT

+49 89 94004391

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

1302

Identifier Type: -

Identifier Source: org_study_id