HEMOTOL: Efficacy and Safety of Hemodialysis On-line Monitoring Devices on Hemodynamic Stability in Intensive Care Unit

NCT ID: NCT00811109

Last Updated: 2010-03-03

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

COMPLETED

Clinical Phase

PHASE2/PHASE3

Total Enrollment

600 participants

Study Classification

INTERVENTIONAL

Study Start Date

2008-12-31

Study Completion Date

2010-01-31

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

The purpose of this randomized controlled study is to compare the effects of different new dialysis on-line monitoring devices on hemodynamic stability during intermittent hemodialysis in critically ill patients with acute kidney injury.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

Acute kidney injury (AKI) is associated with high mortality and morbidity rates in critically ill patients despite advances in renal replacement therapy (RRT). Over the last few years, new devices in dialysis equipment, such as blood temperature and blood volume on-line monitors, have been developed to improve hemodynamic tolerance, and these new modalities have demonstrated their positive impact on decrease in intra-dialytic hypotension rate in chronic hemodialysis patients. In order to evaluate these new devices in critically ill patients with acute kidney injury we decided to conduct a prospective randomized controlled trial.

We based calculation of the sample size on a power analysis that assumed an expected decrease in intra-dialytic hypotension rate of 40% (from a crude intra-dialytic hypotension rate of 30% to 18%) in groups B and C, compared with group A. Analysis is done by intention to treat, according to prescribed new dialysis on-line monitoring devices.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Hemodialysis

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Allocation Method

RANDOMIZED

Intervention Model

PARALLEL

Primary Study Purpose

TREATMENT

Blinding Strategy

NONE

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

Standard

Gold standard bicarbonate hemodialysis therapy with constant ultrafiltration rate and dialysis conductivity

Group Type NO_INTERVENTION

Standard Hemodialysis

Intervention Type DEVICE

Gold standard bicarbonate hemodialysis therapy with constant ultrafiltration rate and dialysis conductivity performed with Fresenius 4008S monitor (Fresenius Medical Care, France)

2

With Blood Volume on-line monitoring only

Group Type ACTIVE_COMPARATOR

with Blood Volume Management (BVM®) only

Intervention Type DEVICE

Hemodialysis using Blood Volume on-line monitoring only. Hemodialysis will be performed with Fresenius 4008S monitor (Fresenius Medical Care, France) equipped with BVM® device (for blood volume monitor; Fresenius Medical Care, France)

3

With Blood volume and Blood temperature on-line monitoring

Group Type ACTIVE_COMPARATOR

with Blood Volume (BVM®) and Temperature (BTM®) on-line monitoring

Intervention Type DEVICE

Hemodialysis using Blood volume and Blood temperature on-line monitoring. Hemodialysis will be performed with Fresenius 4008S monitor (Fresenius Medical Care, France) equipped with BVM® and BTM® devices (for blood volume monitor and blood temperature management, respectively; Fresenius Medical Care, France)

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

Standard Hemodialysis

Gold standard bicarbonate hemodialysis therapy with constant ultrafiltration rate and dialysis conductivity performed with Fresenius 4008S monitor (Fresenius Medical Care, France)

Intervention Type DEVICE

with Blood Volume Management (BVM®) only

Hemodialysis using Blood Volume on-line monitoring only. Hemodialysis will be performed with Fresenius 4008S monitor (Fresenius Medical Care, France) equipped with BVM® device (for blood volume monitor; Fresenius Medical Care, France)

Intervention Type DEVICE

with Blood Volume (BVM®) and Temperature (BTM®) on-line monitoring

Hemodialysis using Blood volume and Blood temperature on-line monitoring. Hemodialysis will be performed with Fresenius 4008S monitor (Fresenius Medical Care, France) equipped with BVM® and BTM® devices (for blood volume monitor and blood temperature management, respectively; Fresenius Medical Care, France)

Intervention Type DEVICE

Other Intervention Names

Discover alternative or legacy names that may be used to describe the listed interventions across different sources.

Treatment A Treatment B Treatment C

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

* Age \> 18 years
* Acute Kidney injury requiring intermittent hemodialysis

Exclusion Criteria

* Age \< 18 years
* End-stage renal failure
* Inclusion in other protocol
* Absence of consent
Minimum Eligible Age

18 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

No

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

University Hospital, Caen

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

University Hospital, Caen

Principal Investigators

Learn about the lead researchers overseeing the trial and their institutional affiliations.

Damien du CHEYRON, MD, PhD

Role: PRINCIPAL_INVESTIGATOR

University Hospital, Caen

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

Service de Réanimation Médicale - CHU de Caen

Caen, , France

Site Status

Countries

Review the countries where the study has at least one active or historical site.

France

References

Explore related publications, articles, or registry entries linked to this study.

Marshall MR, Wang MY, Vandal AC, Dunlop JL. Low dialysate sodium levels for chronic haemodialysis. Cochrane Database Syst Rev. 2024 Nov 5;11(11):CD011204. doi: 10.1002/14651858.CD011204.pub3.

Reference Type DERIVED
PMID: 39498822 (View on PubMed)

du Cheyron D, Terzi N, Seguin A, Valette X, Prevost F, Ramakers M, Daubin C, Charbonneau P, Parienti JJ. Use of online blood volume and blood temperature monitoring during haemodialysis in critically ill patients with acute kidney injury: a single-centre randomized controlled trial. Nephrol Dial Transplant. 2013 Feb;28(2):430-7. doi: 10.1093/ndt/gfs124. Epub 2012 Apr 25.

Reference Type DERIVED
PMID: 22535635 (View on PubMed)

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

A08-D12-VOL.6

Identifier Type: -

Identifier Source: org_study_id

More Related Trials

Additional clinical trials that may be relevant based on similarity analysis.

Lymphatic Occlusion Pressure in Lower Limb
NCT02405559 UNKNOWN EARLY_PHASE1