Feasibility of Ventilation Detection Via Standard Defibrillator Pads in Mechanically Ventilated Pediatric Patients
NCT ID: NCT00628875
Last Updated: 2010-04-14
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
COMPLETED
28 participants
OBSERVATIONAL
2007-01-31
2009-12-31
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
We propose to observe, measure and report the accuracy, precision and bias of defibrillator electrode pads to detect breathing in stable but critically ill and mechanically ventilated children. This study will provide preliminary data to inform the resuscitation research community and assist development of evidence-based pediatric resuscitation guidelines in the future.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Electrophysiological Optimization of Left Ventricular Lead Placement in CRT
NCT02346097
Automated Cardioverter Defibrillator in Children
NCT00268021
Managed Ventricular Pacing ("MVP") Trial
NCT00281099
Comparison of VF Induction Techniques During Medtronic ICD Implant (VF) (ICD)
NCT02027883
The Ability Of The PD2i Cardiac Analyzer To Predict Risk Of Ventricular Tachyarrhythmic Events
NCT00510731
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
Objectives: The primary objective is to evaluate the accuracy, precision, bias and ability of the pads and defibrillator to detect the rate and depth of breathing in critically ill children on breathing machines. Important secondary objectives include reporting the accuracy, precision and bias of the measurement of the speed of the breath, measurement variability, and impact of alternative defibrillator electrode pad location on the chest.
Study Design/Setting/Participants:
Prospective, pilot, observational study in the Pediatric Intensive Care Unit and Progressive Care Unit at the Children's Hospital of Philadelphia. The participants are all patients in the PICU and Progressive Care Unit (PCU), 6 months to 17 years, who are supported by their clinical management team with a tracheal tube, standard breathing machine, and standard ICU monitoring systems.
Intervention:
Standard defibrillator electrode pads will be placed on the patient's chest in two typical pediatric configurations, and data will be recorded for 5 minutes in each configuration. These defibrillator electrode pads will be used exclusively for monitoring, as additions to the standard ICU monitoring.
Study Measures:
The primary outcome variable will be the successful detection of breathing rate. We will compare the accuracy, precision and bias of detection of each breath of \> 2 ml/kg by the defibrillator electrode pads compared with the "gold standard" mechanical ventilator pneumotachometer detected breaths. Secondary outcome variables will include defibrillator electrode pad detection of breathing depth and speed compared to standard ICU monitors (considered the gold standard). We will also study the effect of defibrillator electrode pad location on the accuracy, precision, bias and ability to detect breathing rate, depth, and speed.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
CASE_ONLY
PROSPECTIVE
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
2. Artificial airway
3. Mechanical ventilation (PCV or VCV)
4. Hemodynamic stability to participate in the study, as determined by the clinical treatment team.
5. Parental/guardian permission (informed consent) and if appropriate, child assent.
Exclusion Criteria
2. High frequency ventilation (Jet or Oscillation)
3. Airway Pressure Release ventilation
4. Extracorporeal membrane oxygenation (ECMO)
5. Significant chest wall abnormality (e.g. Vertebral Expandable Prosthetic Titanium Rib (VEPTR) or device precluding typical placement of defibrillator electrode pads)
6. Altered skin integrity in areas where defibrillator electrode pads would be placed
6 Months
17 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Laerdal Medical
INDUSTRY
Children's Hospital of Philadelphia
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Children's Hospital of Philadelphia
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
Kathryn Roberts, MSN, RN, CRNP, CCRN, CCNS
Role: PRINCIPAL_INVESTIGATOR
Children's Hospital of Philadelphia
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Children's Hospital of Philadelphia
Philadelphia, Pennsylvania, United States
Countries
Review the countries where the study has at least one active or historical site.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
2006-10-5022
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.