The Use of a Fully Digital Workflow in Immediate Implants With Immediate Restoration
NCT ID: NCT07294820
Last Updated: 2026-01-09
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
RECRUITING
24 participants
OBSERVATIONAL
2026-01-27
2028-06-30
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Type of study Clinical
Study design Prospective, single-arm using BLC implants with full digital workflow. Patients treated within "Clinical and radiological evaluation of a novel implant design (Straumann BLX) in the esthetic zone: a prospective case series study" (IIS 43/17), published as "Cardaropoli D, Tamagnone L, Roffredo A, Demaria A. Clinical and radiological evaluation of a fully tapered implant with immediate placement in the aesthetic zone: a prospective case series study. Int J Periodontics Restorative Dent. 2022 Sep-Oct;42(5):631-637" will be used for comparison.
Study power N total: 24 Anticipated drop-out rate %: 15 Adequate power analysis and justification A power calculation before the study revealed that a sample size of 20 was necessary to detect a difference of 0.5 mm in the vertical position of the implant between planning and execution of 0.5 mm assuming a maximal standard deviation of 0.7 mm using a paired t test with 80% power and .05 level of significance.
Study intervention - test arm Study Device BLC Implant
Test treatment name Fully digital immediate placement/immediate restoration
Test Treatment description An immediate BLC implant inserted in post-extraction sites in the upper maxilla, from 15 to 25, with immediate restoration.
Primary outcome parameter Pink Esthetic Score (PES from 0 to 14), at 1 year Marginal Bone Level expressed in mm, at 1 year
Secondary outcome parameter PROMS - Patients' satisfaction using VAS scale, at day of surgery and at 1 year Duration of the procedure, at day of surgery Probing Depth (PD) and Bleeding on Probing (BoP) at 1 year
Materials and Methods Population and indication 24 adult systemically healthy patients requiring tooth extraction and single implant tooth replacement, from 1.5 to 2.5
Treatments In the case study phase, a 3D cone-beam radiograph and an intraoral scan are acquired. A computer guided surgical stent is produced from the virtual planning. By sharing the virtual planning, the laboratory designs and produces a temporary crown. On the day of surgery the tooth is extracted, the implant is inserted and the temporary is delivered. The final ceramic crown is delivered 3 months later. Follow-up will end 1 year after implant placement.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Implant Rehabilitations in a Hospital Setting
NCT07332195
20-year Implant Survival in Periodontally Healthy and Compromised Patients
NCT04983758
Full-Digital Workflow in Single-Tooth Implant Rehabilitation
NCT05011604
Immediate Loading and Fully Guided Surgery: Single Implants
NCT04061694
Comparison Between Conventional and Digital Workflow in Dental Prosthesis
NCT06215781
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
Background and rationale Immediate implant insertion is a treatment protocol that allows the insertion of an osseointegrated implant at the same time as tooth extraction. This procedure has high success rates, above 98%, but at the same time a high risk of biological and aesthetic complications. If possible, the delivery of an immediate temporary crown can improve the aesthetic result in terms of maintaining the original soft tissue profile. Planning the intervention becomes a fundamental point in the diagnostic-therapeutic path. It is essential to have three-dimensional radiographic information in order to evaluate the buccal bone plate, and the post-extractions socket. But it is also very important to have detailed information about the position and quality of the soft tissues. This information can be made available by cone-beam radiographic examination and intraoral digital scanning. The digital planning of the implant surgery can be shared with the laboratory which will design the temporary crown and produce it. On the day of surgery, thanks to the computer guided surgical stent, the implant can be inserted in the three-dimensional position as chosen and at the end of the session the temporary crown with its temporary abutment will be delivered. The fully digital workflow can create a minimally invasive, fast and precise treatment protocol, capable of pre-visualizing unfavorable anatomical conditions.
The outcome of this study will be compared with the results obtained from the recently completed clinical trial with similar design (Cardaropoli D, Tamagnone L, Roffredo A, Demaria A. Clinical and radiological evaluation of a fully tapered implant with immediate placement in the aesthetic zone: a prospective case series study. Int J Periodontics Restorative Dent. 2022 Sep-Oct;42(5):631-637.). In this study fully tapered implants with comparable design (BLX) have been placed in post-extraction sockets, from premolar to premolar in the maxilla, and immediately loaded. Marginal bone level (MBL) and probing depth (PD) have been evaluated up to a 12-month follow-up period. All implants osseointegrated achieving a success rate of 100%. Difference in MBL between time of placement and one year was 0.20 ± 0.04 mm, while PD at one year was 2.82±0.51. Data here reported support the use of a fully tapered implant for immediate placement and immediate loading, for single-tooth replacements in the aesthetic area.
Study hypothesis The hypothesis is that a full-digital workflow for immediate implant placement with immediate restoration is able to provide at least the same outcomes as standard analog implant placement in the same clinical scenario (immediate placement with immediate loading), in terms of implant success and survival and marginal bone level stability. A VAS scale evaluation will be created to measure patients' aesthetic and overall satisfaction, as well the duration of the procedure will be measured.
Type of study Clinical
Study design Prospective, single-arm using BLC implants with full digital workflow. Patients treated within "Clinical and radiological evaluation of a novel implant design (Straumann BLX) in the esthetic zone: a prospective case series study" (IIS 43/17), published as "Cardaropoli D, Tamagnone L, Roffredo A, Demaria A. Clinical and radiological evaluation of a fully tapered implant with immediate placement in the aesthetic zone: a prospective case series study. Int J Periodontics Restorative Dent. 2022 Sep-Oct;42(5):631-637" will be used for comparison.
Study power N total: 24 Anticipated drop-out rate %: 15 Adequate power analysis and justification A power calculation before the study revealed that a sample size of 20 was necessary to detect a difference of 0.5 mm in the vertical position of the implant between planning and execution of 0.5 mm assuming a maximal standard deviation of 0.7 mm using a paired t test with 80% power and .05 level of significance.
Study intervention - test arm Study Device BLC Implant
Test treatment name Fully digital immediate placement/immediate restoration
Test Treatment description An immediate BLC implant inserted in post-extraction sites in the upper maxilla, from 15 to 25, with immediate restoration.
Primary outcome parameter Pink Esthetic Score (PES from 0 to 14), at 1 year Marginal Bone Level expressed in mm, at 1 year
Secondary outcome parameter PROMS - Patients' satisfaction using VAS scale, at day of surgery and at 1 year Duration of the procedure, at day of surgery Probing Depth (PD) and Bleeding on Probing (BoP) at 1 year
Materials and Methods Population and indication 24 adult systemically healthy patients requiring tooth extraction and single implant tooth replacement, from 1.5 to 2.5
Treatments In the case study phase, a 3D cone-beam radiograph and an intraoral scan are acquired. A computer guided surgical stent is produced from the virtual planning. By sharing the virtual planning, the laboratory designs and produces a temporary crown. On the day of surgery the tooth is extracted, the implant is inserted and the temporary is delivered. The final ceramic crown is delivered 3 months later. Follow-up will end 1 year after implant placement.
Statistical methods paired t-test
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
CASE_ONLY
PROSPECTIVE
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
oral implant
fully guided implant placement with a computer guided surgical stant
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
18 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Proed, Torino, Italy
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Daniele Cardaropoli
Prof Dr
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Studio Dottor Cardaropoli
Turin, Piedmont, Italy
Countries
Review the countries where the study has at least one active or historical site.
Central Contacts
Reach out to these primary contacts for questions about participation or study logistics.
Facility Contacts
Find local site contact details for specific facilities participating in the trial.
References
Explore related publications, articles, or registry entries linked to this study.
Cardaropoli D, Tamagnone L, Roffredo A, De Maria A. Clinical and Radiologic Evaluation of a Fully Tapered Implant with Immediate Placement in the Esthetic Zone: A Prospective Case Series Study. Int J Periodontics Restorative Dent. 2022 Sep-Oct;42(5):631-637. doi: 10.11607/prd.5682.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
12.2025.IIPP.STR.IIS07/24
Identifier Type: -
Identifier Source: org_study_id