Comparing 3D and 2D Views in Biportal Spine Surgery: A Pilot Simulation Study

NCT ID: NCT07171801

Last Updated: 2025-09-16

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

NOT_YET_RECRUITING

Clinical Phase

NA

Total Enrollment

6 participants

Study Classification

INTERVENTIONAL

Study Start Date

2025-10-01

Study Completion Date

2025-12-01

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

This study aims to compare three-dimensional (3D) and two-dimensional (2D) visualization in biportal endoscopic spine surgery using a simulated environment. Surgeons will perform standardized tasks on a spine model while using either 3D or 2D endoscopic systems. The goal is to determine whether 3D technology can improve precision, efficiency, and movement control during surgery. The study uses a randomized, blinded, crossover design to ensure objective results and may help guide future training and technology use in spinal endoscopy.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

Spinal endoscopy, particularly the unilateral biportal endoscopic (UBE) technique, is an increasingly adopted minimally invasive approach for treating lumbar spine pathologies. While it offers clinical advantages over traditional open surgery-including less tissue disruption, reduced blood loss, and faster recovery-its uptake has been limited, in part due to the technical challenges associated with two-dimensional (2D) endoscopic visualization. The lack of depth perception inherent to 2D imaging can impair spatial orientation, hand-eye coordination, and surgical precision, especially in anatomically complex regions such as the lumbar spine.

Three-dimensional (3D) endoscopic systems are designed to address this limitation by restoring binocular depth cues and providing stereoscopic visualization. Preliminary evidence from other surgical fields-such as laparoscopy and cranial neurosurgery-suggests that 3D visualization improves operative performance, task efficiency, and user confidence. However, the benefits of 3D visualization in spinal endoscopy remain poorly understood, with no rigorous controlled studies to date assessing its impact on performance metrics under standardized conditions.

This randomized, blinded, crossover pilot study is designed to objectively evaluate the effect of 3D versus 2D endoscopic visualization on technical performance during simulated UBE procedures. Participants-including surgeons at various experience levels-will complete standardized surgical tasks on high-fidelity lumbar spine models using both 2D and 3D endoscopic systems. Motion tracking technology will be employed to quantitatively analyze instrument movement, capturing key metrics such as path length, velocity, motion economy, and high-velocity excursions.

The crossover design ensures that each participant serves as their own control, and blinding minimizes observational bias during performance assessment. The simulation setting allows for reproducible conditions free from patient-related variability, ensuring that observed differences can be attributed to visualization modality rather than anatomical or clinical complexity.

Findings from this study will provide foundational data on the potential utility of 3D visualization in spinal endoscopy, with implications for surgical training, operative safety, and the future integration of stereoscopic technologies in spine surgery.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Spinal Diseases Endoscopy Simulation Lumbar Vertebrae Randomized Controlled Trial Three-Dimensional Simulation Training

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Allocation Method

RANDOMIZED

Intervention Model

CROSSOVER

This study employs a randomized, single-center, blinded, crossover design in a high-fidelity simulated surgical environment. Each participant performs standardized unilateral biportal endoscopic spine surgery tasks using both 2D and 3D visualization systems in a randomized sequence. A washout period is incorporated between conditions to minimize carryover effects. This within-subjects crossover model allows each participant to serve as their own control, increasing statistical power and reducing inter-individual variability. Blinding is maintained for performance assessors, and objective motion tracking metrics are used to evaluate technical performance under each visualization condition.
Primary Study Purpose

DEVICE_FEASIBILITY

Blinding Strategy

SINGLE

Outcome Assessors
In this single-center crossover simulation study, outcomes assessors responsible for performance evaluation and motion data analysis are blinded to the visualization modality used during each session (3D or 2D). Participants are not blinded due to the inherent perceptual differences between the two visualization systems. Investigators supervising the simulation are aware of the intervention assignments for operational purposes but are not involved in outcome assessment. All video and motion tracking data are anonymized and coded prior to analysis to maintain assessor blinding.

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

Three-Dimensional Endoscopy First, Then Two-Dimensional

Participants first perform standardized spinal endoscopic simulation tasks using a stereoscopic three-dimensional (3D) endoscopic system providing binocular depth perception via dual optical channels and polarized glasses. After completing all tasks under 3D visualization, the same participants subsequently repeat the identical tasks using conventional two-dimensional (2D) visualization on the same high-definition endoscopic platform

Group Type OTHER

Three-Dimensional Endoscopic Visualization

Intervention Type DEVICE

Use of a stereoscopic 3D high-definition endoscopic system with dual optical channels, projecting to a stereoscopic monitor viewed with polarized glasses, to perform standardized spinal simulation tasks.

Two-Dimensional Endoscopic Visualization

Intervention Type DEVICE

Use of the same high-definition endoscopic system with stereoscopic function deactivated, providing conventional monoscopic two-dimensional visualization, to perform standardized spinal simulation tasks.

Two-Dimensional Endoscopy First, Then Three-Dimensional

Participants first perform standardized spinal endoscopic simulation tasks using conventional two-dimensional (2D) visualization, with stereoscopic capability deactivated, displaying a monoscopic high-definition image. After completing all tasks under 2D visualization, the same participants subsequently repeat the identical tasks using stereoscopic three-dimensional (3D) visualization on the same endoscopic platform, viewed with polarized glasses.

Group Type OTHER

Three-Dimensional Endoscopic Visualization

Intervention Type DEVICE

Use of a stereoscopic 3D high-definition endoscopic system with dual optical channels, projecting to a stereoscopic monitor viewed with polarized glasses, to perform standardized spinal simulation tasks.

Two-Dimensional Endoscopic Visualization

Intervention Type DEVICE

Use of the same high-definition endoscopic system with stereoscopic function deactivated, providing conventional monoscopic two-dimensional visualization, to perform standardized spinal simulation tasks.

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

Three-Dimensional Endoscopic Visualization

Use of a stereoscopic 3D high-definition endoscopic system with dual optical channels, projecting to a stereoscopic monitor viewed with polarized glasses, to perform standardized spinal simulation tasks.

Intervention Type DEVICE

Two-Dimensional Endoscopic Visualization

Use of the same high-definition endoscopic system with stereoscopic function deactivated, providing conventional monoscopic two-dimensional visualization, to perform standardized spinal simulation tasks.

Intervention Type DEVICE

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

* Enrolled in the neurosurgical residency or fellowship program at the Department of Neurosurgery, Cantonal Hospital of St. Gallen, Switzerland
* Completion of basic neurosurgical training modules, including introductory endoscopic handling
* Age ≥ 18 years
* Willingness and ability to provide informed consent

Exclusion Criteria

* Prior substantial experience with three-dimensional (3D) endoscopy (defined as \> 5 independent procedures performed with 3D visualization systems)
* Ocular or neurological conditions impairing stereopsis, fine motor control, or safe endoscope handling
* Inability or unwillingness to complete the simulation protocol
* Declined participation
Minimum Eligible Age

18 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

Yes

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

Felix Corr

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Felix Corr

Stefan Motov

Responsibility Role SPONSOR_INVESTIGATOR

Principal Investigators

Learn about the lead researchers overseeing the trial and their institutional affiliations.

Stefan Motov, MD

Role: PRINCIPAL_INVESTIGATOR

Kantonsspital St. Gallen, Health Ostschweiz

Central Contacts

Reach out to these primary contacts for questions about participation or study logistics.

Felix Corr, MD, MSc.

Role: CONTACT

+41 71 494 1636

References

Explore related publications, articles, or registry entries linked to this study.

Ban Y, Mcneely B, Chadha NK, Felton M. Safety and efficacy of three-dimensional versus two-dimensional endoscopy in otolaryngology surgery and training: A systematic review. Clin Otolaryngol. 2024 Sep;49(5):538-551. doi: 10.1111/coa.14171. Epub 2024 May 12.

Reference Type BACKGROUND
PMID: 38735751 (View on PubMed)

Heo DH, Kim JY, Park JY, Kim JS, Kim HS, Roh J, Park CK, Chung H. Clinical Experiences of 3-Dimensional Biportal Endoscopic Spine Surgery for Lumbar Degenerative Disease. Oper Neurosurg. 2022 Apr 1;22(4):231-238. doi: 10.1227/ONS.0000000000000090.

Reference Type BACKGROUND
PMID: 35147593 (View on PubMed)

Ma A, Xie N, Reidy J, Mobbs RJ. Three-dimensional endoscopy in lumbar spine surgery as a novel approach for degenerative pathologies: a case report. J Surg Case Rep. 2024 Aug 28;2024(8):rjae540. doi: 10.1093/jscr/rjae540. eCollection 2024 Aug.

Reference Type BACKGROUND
PMID: 39211372 (View on PubMed)

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

V1

Identifier Type: -

Identifier Source: org_study_id

More Related Trials

Additional clinical trials that may be relevant based on similarity analysis.

Prevena Spine for Use in Spine Surgery
NCT05555355 COMPLETED PHASE4
Pedicle Screw Placement With XVS
NCT04682418 COMPLETED NA