Wearable Garment vs Gel Electrodes for Electrical Muscle Stimulation
NCT ID: NCT07050784
Last Updated: 2025-07-08
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
NOT_YET_RECRUITING
NA
20 participants
INTERVENTIONAL
2025-07-01
2025-09-30
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
The main questions it aims to answer are:
1. Is the perceived sensation of stimulation using textile electrodes non-inferior to that of hydrogel electrodes?
2. Is the current required to evoke muscle contractions similar between textile and hydrogel electrodes?
Each participant will complete three stimulation conditions in random order across separate visits:
1. hydrogel electrodes (standard),
2. dry polymer-textile electrodes with lotion, and
3. dry textile electrodes with hydrogel pads
Electrical stimulation will be delivered to the lower leg muscles using a wearable sleeve with integrated electrodes. The investigators will assess sensorimotor thresholds (e.g., detection, motor, and full motor threshold), skin-electrode impedance, and torque. Participants will also rate stimulation comfort, intensity, and sensation location via questionnaire.
After the three primary arms, participants may optionally complete two additional arms using different moisturizers applied to the textile electrodes to evaluate their impact on stimulation performance.
The results of this study will help determine whether textile electrodes can be used as an effective and comfortable alternative to hydrogel electrodes in wearable neurostimulation applications.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Effect of Electrical Muscle Stimulation in Critically Ill Patients
NCT01637467
Neuromuscular Electrical Stimulation Via the Peroneal Nerve Reduces Muscle Soreness Following Intermittent Exercise
NCT02018211
Influence of Electrode Positioning and Current Type on Fatigue, Force and Discomfort
NCT04200677
Direct Current Neuromuscular Electrical Stimulation for Treatment of Peripheral Neuropathy
NCT05442021
Evaluation in 15 Participants of Blood Flow, Comfort and Efficiency, Using 1 vs 36 Hz Stimulation Via Textile Electrodes
NCT06082297
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
Textile-based electrodes are an emerging alternative. These electrodes are integrated into wearable garments, making them washable, reusable, and more comfortable for extended wear times. However, research directly comparing their effectiveness and user experience compared to hydrogel electrodes is limited.
The goal of this study is to compare textile electrodes to gold-standard hydrogel electrodes for muscle activation and perceived stimulation sensation. The investigators hypothesize that: 1) there will be no clinically meaningful difference in participants' perception of the stimulation between textile and hydrogel electrodes, and 2) there will be no significant difference in the stimulation current required to elicit functional contractions.
This is a crossover randomized controlled trial involving three primary arms: 1) hydrogel electrodes, 2) dry polymer-textile electrodes with lotion, and 3) dry textile electrodes with gel pads applied. Each participant will perform all three arms in a randomized order with at least 24 hours between visits. Stimulation will be delivered to the calf and tibialis anterior muscles using the same electrical stimulator and settings in all conditions. Following completion of the three primary arms, participants will be given the option to complete an additional two arms using different types of commercially available moisturizers on the dry textile electrodes to assess comparative on-body performance of different water-based moisturizers. All moisturizers are commercially available and are labelled Skin Lotion A, B, and C in the 'Arms and Interventions' section.
A sample size of 18 participants is required to detect a Cohen's f of 0.40 with 95% power and a significance level of ⍺ = 0.05 for a within-subjects one-way repeated measures analysis of variance (ANOVA) with three conditions. To preserve statistical power, the investigators will recruit 20 participants. Pilot data comparing textile to hydrogel electrodes provided an estimated effect size of f = 0.65. Given the pilot data was not randomized, which likely inflated the observed effect size, the investigators conservatively based their sample size calculation on a Cohen's f of 0.40 (i.e., a large effect size) to ensure adequate power to detect a potentially smaller true effect.
A non-inferiority analysis will compare perceived stimulation intensity on a 10-point numerical rating scale. A 2-point difference is set as the non-inferiority margin based on prior research on the minimal clinically important difference. Textile electrodes will be considered non-inferior if the upper bound of the 95% confidence interval for the difference in intensity remains below this threshold. Repeated measures ANOVAs and Tukey's post hoc tests will be used to analyze the outcome variables where appropriate.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
RANDOMIZED
CROSSOVER
BASIC_SCIENCE
NONE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
Hydrogel electrodes
Gold-standard comparator
Hydrogel electrodes
Neurostimulation using standard self-adhesive hydrogel electrodes
Dry polymer-textile electrodes with Skin Lotion A
Dry polymer-textile electrodes with Skin Lotion A
Neurostimulation with dry polymer-textile electrodes using Skin Lotion A
Dry textile electrodes with gel pads attached to the electrode
Dry textile electrodes with gel pads attached to the electrode
Neurostimulation with dry textile electrodes with gel pads attached to the electrode
Dry polymer-textile electrodes with Skin Lotion B
Dry polymer-textile electrodes with Skin Lotion B
Neurostimulation with dry polymer-textile electrodes with Skin Lotion B
Dry polymer-textile electrodes with Skin Lotion C
Dry polymer-textile electrodes with Skin Lotion C
Neurostimulation with dry polymer-textile electrodes using Skin Lotion C
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
Hydrogel electrodes
Neurostimulation using standard self-adhesive hydrogel electrodes
Dry polymer-textile electrodes with Skin Lotion A
Neurostimulation with dry polymer-textile electrodes using Skin Lotion A
Dry textile electrodes with gel pads attached to the electrode
Neurostimulation with dry textile electrodes with gel pads attached to the electrode
Dry polymer-textile electrodes with Skin Lotion B
Neurostimulation with dry polymer-textile electrodes with Skin Lotion B
Dry polymer-textile electrodes with Skin Lotion C
Neurostimulation with dry polymer-textile electrodes using Skin Lotion C
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
Exclusion Criteria
* Implanted defibrillator or pacemaker
* Pain in the body part being tested
* Open wound or dressing (e.g. band-aid) on a body part that needs to be in contact with the electrodes
* Severe frailty such that donning or doffing the garment may cause a danger of falling
18 Years
ALL
Yes
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Myant Medical Corp.
INDUSTRY
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
Milad Alizadeh Meghrazi
Role: PRINCIPAL_INVESTIGATOR
Myant Medical Corp.
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Myant Medical Corp
Mississauga, Ontario, Canada
Countries
Review the countries where the study has at least one active or historical site.
Central Contacts
Reach out to these primary contacts for questions about participation or study logistics.
Facility Contacts
Find local site contact details for specific facilities participating in the trial.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
157491
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.