Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
The light transmittance ratio of the crystalline lens is high and as a monofocal ocular medium that has the ability to modify its shape and geometric properties according to the focal point. Therefore, it is capable of delivering the exact same light energy to the retina, regardless of the distance of the object. Trifocal IOL designs split the light in three focal points. By varying the height of the diffractive step, the amount of light distributed to near, intermediate and distant foci is adjusted according to pupil aperture. The distribution of light to three different foci includes several potential disadvantages, such as loss of visual acuity in mesopic conditions and a loss of contrast sensitivity. Thus, the visual performance of multifocal IOLs depends on several factors, the addition (add) power is a major determinant of the actual range of clear vision, another factor is the light transmittance characteristics of the lens (e.g., the incorporation of a blue light filter).
As different trifocal IOLs become available, it is important to have information on their characteristics regarding visual acuity in order to be able to recommend an IOL that meets the individualized needs of each patient. In order to provide the patient with a high visual acuity in all promised distances, these IOLs need to be aimed at and achieve emmetropia.
Furthermore, multifocal IOLs need good capsular bag centration, they need to remain as unaffected as possible by capsular bag constriction and remain stable in their axial lens position in order to provide a stable refraction after surgery.
The investigators compare the anterior chamber depth stability as marker for positional stability and haptic buckling between two different diffractive IOL designs, one with C-loop haptics and one with plate haptics. Furthermore, the refractive outcome of these IOLs with different designs is examined in photopic and mesopic conditions, as well as visual acuity results for both IOLs.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Visual Performance Following Implantation of Presbyopia Correcting IOLs
NCT04907955
Evaluating Presbyopia-Correcting IOLs in Complex Cataract Cases With Anterior Segment Abnormalities
NCT07321756
Visual Performance of New Apodized Diffractive Multifocal IOL With Addition of Plus Three
NCT01027533
A Comparison of the Visual Performance of Trifocal Versus Extended Depth of Focus Intraocular Lenses
NCT03726606
Wavefront Analisys and Contrast Sensitivity of Spherical and Aspherical Intraocular Lenses
NCT00347243
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
COHORT
PROSPECTIVE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
Multifocal IOL 1
bilateral pseudophakia with multifocal IOL 1 (Johnson and Johnson Synergy)
No intervention is subject of the study. Only standard pre- and postoperative data will be evaluated.
No intervention is subject of the study. Only standard pre- and postoperative data will be evaluated. Including data from testing refraction, visual acuity, biometry, tomography, and OCT.
Multifocal IOL 2
bilateral pseudophakia with multifocal IOL 2 (Carl Zeiss Meditec AT Lisa Tri)
No intervention is subject of the study. Only standard pre- and postoperative data will be evaluated.
No intervention is subject of the study. Only standard pre- and postoperative data will be evaluated. Including data from testing refraction, visual acuity, biometry, tomography, and OCT.
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
No intervention is subject of the study. Only standard pre- and postoperative data will be evaluated.
No intervention is subject of the study. Only standard pre- and postoperative data will be evaluated. Including data from testing refraction, visual acuity, biometry, tomography, and OCT.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
2. Able to provide written informed consent and follow study instructions in English or German.
3. Desire for spectacle independence
4. Agreement on clinical decision for planned crystalline lens exchange with multifocal IOL implantation (Standardized femtosecond-laser capsulotomy (diameter 5.3mm))
5. Willing and able to return for scheduled follow-up examinations;
Exclusion Criteria
2. Zonular-defects, unstable bag
3. Macular pathologies
4. Excessive irregular astigmatism
6\. Pregnancy/lactation 7. Predicted Visual acuity of less than 0.8 decimal 8. Participating in any other ophthalmic drug or device clinical trial during the time of this clinical investigation;
45 Years
ALL
Yes
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
AMO Ireland
UNKNOWN
IROC AG
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Theo Seiler
Prof. Dr. med. Dr. rer. nat.
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
Theo Seiler, MD
Role: PRINCIPAL_INVESTIGATOR
IROC AG
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
IROC
Zurich, Canton of Zurich, Switzerland
Countries
Review the countries where the study has at least one active or historical site.
References
Explore related publications, articles, or registry entries linked to this study.
Benyoussef AA, Reboux N, Cochener B. Comparison of Bilateral Reading Performance Among Two Presbyopia-Correcting Intraocular Lenses. J Refract Surg. 2022 Jul;38(7):428-434. doi: 10.3928/1081597X-20220516-02. Epub 2022 Jul 1.
Seiler TG, Wegner A, Senfft T, Seiler T. Dissatisfaction After Trifocal IOL Implantation and Its Improvement by Selective Wavefront-Guided LASIK. J Refract Surg. 2019 Jun 1;35(6):346-352. doi: 10.3928/1081597X-20190510-02.
Cillino G, Casuccio A, Pasti M, Bono V, Mencucci R, Cillino S. Working-age cataract patients: visual results, reading performance, and quality of life with three diffractive multifocal intraocular lenses. Ophthalmology. 2014 Jan;121(1):34-44. doi: 10.1016/j.ophtha.2013.06.034. Epub 2013 Aug 14.
Marques EF, Ferreira TB. Comparison of visual outcomes of 2 diffractive trifocal intraocular lenses. J Cataract Refract Surg. 2015 Feb;41(2):354-63. doi: 10.1016/j.jcrs.2014.05.048.
Martinez-de-la-Casa JM, Carballo-Alvarez J, Garcia-Bella J, Vazquez-Molini JM, Morales L, Sanz-Fernandez JC, Polo V, Garcia-Feijoo J. Photopic and Mesopic Performance of 2 Different Trifocal Diffractive Intraocular Lenses. Eur J Ophthalmol. 2017 Jan/Feb;27(1):26-30. doi: 10.5301/ejo.5000814.
Alio JL, Kaymak H, Breyer D, Cochener B, Plaza-Puche AB. Quality of life related variables measured for three multifocal diffractive intraocular lenses: a prospective randomised clinical trial. Clin Exp Ophthalmol. 2018 May;46(4):380-388. doi: 10.1111/ceo.13084. Epub 2017 Nov 29.
Portney V. Light distribution in diffractive multifocal optics and its optimization. J Cataract Refract Surg. 2011 Nov;37(11):2053-9. doi: 10.1016/j.jcrs.2011.04.038.
Hienert J, Hirnschall N, Ruiss M, Ullrich M, Zwickl H, Findl O. Prospective study to compare axial position stability after fellow-eye implantation of 2 distinct intraocular lens designs. J Cataract Refract Surg. 2021 Aug 1;47(8):999-1005. doi: 10.1097/j.jcrs.0000000000000557.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
IE9970584V
Identifier Type: OTHER_GRANT
Identifier Source: secondary_id
EMEA202102
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.