Patient's Satisfaction of Mandibular Implant Supported Overdentures With Reduced Denture Base Extensions.
NCT ID: NCT06850558
Last Updated: 2025-08-17
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
COMPLETED
NA
20 participants
INTERVENTIONAL
2024-01-04
2025-02-14
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
A within-subject study design was carried out; involving 20 completely edentulous participants aged 50-75 years, who received newly constructed conventional complete denture. Four parallel implants were installed in the interforaminal region, implant overdenture (IOD) retained by bar attachment was constructed for each patient and were provided with two different overdenture designs: (1)firstly a fully extended denture base (FIOD) (2) then a reduced (partially extended) denture base (RIOD). Each patient allowed to wear each types of overdentures for a period of 3 months prior to evaluation. The following outcome measures were assessed: Patient satisfaction, the Oral Health Impact Profile (OHIP-14), and Chewing efficiency were assessed.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Implant Retained Overdenture VERSUS Implant Canine Retained Overdenture.
NCT07046104
Patient Satisfaction and Oral Health-Related Quality of Life of Quadrilateral Versus Bilateral Linear Bar Designs for Four Implant Implant-Assisted Complete Mandibular Overdenture Regarding Peri-Implant Crestal Bone Loss
NCT06673173
Edentulous Maxilla Opposed by 2-implant Mandibular Overdenture?
NCT06050213
Evaluation of Masticatory Performance and Patient Satisfaction for Conventional and 3D Printed Implant Overdentures
NCT06148727
Four Implant Retained Mandibular Overdenture VERSUS Fixed-detachable Prosthesis.
NCT07144787
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
Study Protocol
1. Randomization: No randomization was done, the order of denture type presentation (was firstly fully extended then reduced design for each participant.
2. Adaptation Period: Participants were allowed a 3-months adaptation period for each Overdenture type to ensure familiarity and comfort.
3. Data Collection Schedule: Data for patient satisfaction, OHRQoL, and masticatory efficiency were collected at the end of each adaptation period. Data were collected at 3 months after use for each design, starting with FE design then RE.
Sample size and participants selection A total of 20 participants, aged 50-75 years, were recruited from the outpatient prosthodontic clinic, Faculty of Dentistry, Mansoura University. The sample size was determined based on a power analysis, aiming for an 80% power to detect significant differences at an alpha level of 0.05 and according to previous research in similar domains often utilized the same sample sizes.
Ethical Considerations The study was conducted in accordance with the Declaration of Helsinki, and ethical approval was obtained from the ethical committee, faculty of dentistry (A08011024RP). Informed consent was obtained from all participants prior to their involvement in the study. Participants were informed of their right to withdraw at any time without affecting their treatment.
Prosthetic and surgical procedures Newly constructed dentures with optimal flanges extension and balanced occlusal scheme using semi-anatomic acrylic teeth were delivered to all participants.
The participants were instructed to use the dentures for three months before implant placement to promote satisfactory neuromuscular control.
Following osseointegration duration, an open tray fixture level impression technique was performed using long transfer copings after splinting the copings with wire and auto polymerized resin (Duralay, Reliance Dental, Alsip, USA) to avoid movement during impression removal. The implant analogs were connected to the copings and the impression was poured. For Bar overdenture (BOD) prosthesis, plastic caps were screwed to bar abutments. Dolder bar joint plastic pattern (Dolder bar joint, Dentaurum) was lute to the caps with about 12mm distal cantilevers to reach the area of mandibular first molars. A 1-1.5 mm clearance space was kept between the ridge and the bar for cleaning reasons. The plastic bar was cast into cobalt-chromium and tried intraorally using Sheffield single screw test to check passivity. Titanium Dolder bar clips were fastened over the bar before processing of acrylic resin. The bar was then fitted with retentive clips or housings, which interfaced with the overdenture with fully extended base (FIOD), ensuring positive retention.
Following the 3 months period from FIOD mandibular implant overdenture use, data were collected then the overdenture was sent to the lab for reducing the denture base extension. The participant wore the mandibular implant overdenture with reduced denture base (Reduced Base Design) (RIOD) for another 3 months and the data were collected again .
Reduced (Partially Extended) Denture Base (RE): (R) A shorter base extending to the anterior portion of the mandible, designed to leave more space for tongue movement and enhance sensory feedback.
The design specifics are as follows:
\- Geometric Configuration: The reduced base extends anteriorly to cover the anterior residual ridge while curving gently around the retromolar pad area. The posterior border is strategically positioned above the retromolar area to prevent impingement on the tissues and to allow for greater tongue space.
Dimensions: The dimensions of the reduced base were tailored individually based on each patient's anatomical features. The following measurements were taken into account:
* Anterior extension cut-off: 2 mm above the anterior alveolar ridge.
* Posterior limit: 5 mm anterior to the retromolar pad, which allows for optimal retention and avoids undue pressure on the underlying tissues.
* Buccal and lingual flanges were designed with a tapered profile to enhance aesthetic and functional features while maintaining adequate reinforcement.
Retention Mechanism: The overdenture was retained by four osseointegrated implants using bar-type attachments. These mechanisms were chosen for their ease of use and effective retention while allowing for minimal stress on the remaining alveolar ridge.
Statistical analysis:
Descriptive statistics were represented in the form of Mean ±Standard deviation (SD) .data was normally distributed as detected by Shapiro-wilk test. To compare patient satisfaction and OHRQoL scores between the 2 overdenture designs, Un-paired samples t-test was utilized as it was parametric data. While Wilcoxon signed-rank tests was applied to evaluate differences in masticatory efficiency measures as it was non-parametric data. The software package used for data analysis was SPSS® version 25 (SPSS Inc., Chicago, IL, USA). The level of significance was adjusted at 5%.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
NON_RANDOMIZED
CROSSOVER
TREATMENT
NONE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
fully extended denture base
Patient allowed to wear fully extended overdenture base for a period of 3 months prior to evaluation after implants installation (four parallel implants) in the interforaminal region.
Four parallel implants were installed in the interforaminal region
All participants administrated prophylactic antibiotics one day before implant placement and continued 7 days after surgery. Participants were asked to rinse their mouth with chlorhexidine mouthwash just before surgery and 7 days after surgery. Under local anesthesia, four implants were placed bilaterally in the interforaminal region. Four parallel implants (TioLogic, Dentaurum) were inserted in the inter-foraminal area using the submerged surgical approach and delayed loading protocol. By using the stereolithographic surgical guide the Implants were installed by the same surgeon with a minimum torque of 35 Ncm to give high initial stability. Relief was done in the mandibular denture over the implants and tissue conditioner (Visco-gel; DENTSPLY, Weybridge, UK) was used as a relining material. osseointegration was allowed to occur for a period of 3-6 months prior to final restoration.
partially extended denture base
Patient allowed to wear partially (reduced) extended overdenture base for a period of 3 months prior to evaluation after implants installation (four parallel implants) in the interforaminal region.
Four parallel implants were installed in the interforaminal region
All participants administrated prophylactic antibiotics one day before implant placement and continued 7 days after surgery. Participants were asked to rinse their mouth with chlorhexidine mouthwash just before surgery and 7 days after surgery. Under local anesthesia, four implants were placed bilaterally in the interforaminal region. Four parallel implants (TioLogic, Dentaurum) were inserted in the inter-foraminal area using the submerged surgical approach and delayed loading protocol. By using the stereolithographic surgical guide the Implants were installed by the same surgeon with a minimum torque of 35 Ncm to give high initial stability. Relief was done in the mandibular denture over the implants and tissue conditioner (Visco-gel; DENTSPLY, Weybridge, UK) was used as a relining material. osseointegration was allowed to occur for a period of 3-6 months prior to final restoration.
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
Four parallel implants were installed in the interforaminal region
All participants administrated prophylactic antibiotics one day before implant placement and continued 7 days after surgery. Participants were asked to rinse their mouth with chlorhexidine mouthwash just before surgery and 7 days after surgery. Under local anesthesia, four implants were placed bilaterally in the interforaminal region. Four parallel implants (TioLogic, Dentaurum) were inserted in the inter-foraminal area using the submerged surgical approach and delayed loading protocol. By using the stereolithographic surgical guide the Implants were installed by the same surgeon with a minimum torque of 35 Ncm to give high initial stability. Relief was done in the mandibular denture over the implants and tissue conditioner (Visco-gel; DENTSPLY, Weybridge, UK) was used as a relining material. osseointegration was allowed to occur for a period of 3-6 months prior to final restoration.
Other Intervention Names
Discover alternative or legacy names that may be used to describe the listed interventions across different sources.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
* Completely edentulous mandibular arch with adequate bone volume (≥10 mm in height and ≥ 6 mm in width at the implant site) and density to allow placement of 4 osseointegrated implants in the interforaminal region.
* Good general health, with no history of systemic diseases that would contraindicate implant placement or the use of overdentures.
* Presence of sufficient inter-arch space for overdenture construction and implant placement.
* No history of severe bruxism or parafunctional habits that could affect implant stability or prosthetic outcomes.
* Ability to understand and complete questionnaires regarding patient satisfaction and quality of life.
* Willingness to comply with the study protocol and attending follow-up visits.
Exclusion Criteria
* Neurological disorders affecting masticatory function.
* Presence of uncontrolled systemic diseases.
* Cognitive impairments affecting the ability to provide informed consent.
* Severe bone resorption or contraindications for implant placement (e.g., insufficient ridge height or width).
* Presence of systemic diseases affecting oral health (e.g., uncontrolled diabetes, systemic inflammatory disorders).
* Inability to wear dentures for extended periods or intolerance to the study protocol
7\. Inability to wear dentures for extended periods or intolerance to the study protocol
50 Years
75 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Mansoura University
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Mohamed Elgamal
Associate professor of prosthodontics
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
Mohamed E Elgamal, PhD
Role: PRINCIPAL_INVESTIGATOR
Mansoura University
Abdallah M Ibrahim, PhD
Role: STUDY_DIRECTOR
Mansoura University
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Removable prosthodontics department,Faculty of dentistry,Mansoura university, #68 ElGomhoria Street, ElMansoura, Egypt.
Al Mansurah, Eldakahlia, Egypt
Countries
Review the countries where the study has at least one active or historical site.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
A08011024RP
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.