Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
RECRUITING
30 participants
OBSERVATIONAL
2024-01-24
2026-12-31
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
The investigators hypothesize that the contact OCT system is superior in imaging larger areas of the retina (larger field-of-view), while it has similar resolution to image the retina substructures (non-inferior image quality).
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Widefield Confocal Scanning Laser Ophthalmoscope Optimized for Pediatric and Neonatal Imaging
NCT06177639
Utilizing Hyperpolarized 129Xe Magnetic Resonance Imaging in Children With Primary Ciliary Dyskinesia
NCT04858191
PCI Imaging System in Pediatric Ophthalmology
NCT02617862
Spectroscopic Evaluation of Middle Ear Infection (Withdrawn)
NCT01485471
TopQ Cut-off Determination Study For 3D-OCT 1 Maestro and 3D OCT-2000
NCT02203981
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
The investigators plan to enroll 10 healthy adult volunteers and 20 pediatric patients in clinic or undergoing examination under anesthesia. This is an observational study. There are no known risks associated with handheld OCT imaging and no adverse events identified imaging with our prior investigational imaging with the same system. There is a risk of corneal abrasion with the contact imaging system (Theia imaging), however, this system is used in the setting of other contact imaging systems (such as RetCam fundus photography).
Imaging data will be downloaded to a secure server for protocol image processing, segmentation, and analysis per protocol in the Duke Advanced Research in SD/SSOCT Imaging (DARSI) Laboratory.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
COHORT
PROSPECTIVE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
Group 1: Healthy adult volunteers
Healthy adult volunteers recruited from the patient population, students or employees of Duke University or Duke Eye Center (n=10)
Investigational contact OCT system
Theia imaging is developing handheld OCT systems bring state of the art OCT to the infant bedside. The Theia 1 widefield imaging system is a light weight, high speed (300 kHz), wide field of view (110°) OCT system that address the limitations of current commercial OCT systems. The system is cart mounted, enabling portable, bedside imaging. The system uses a 300 kHz swept source laser operating in 1060nm regime. The Theia system follows the same safety standards as all applicable laser safety standards (ANSI z80.36 or ISO 15004) as the currently approved prior OCT devices. This nearly 10-fold increase in acquisition speed dramatically reduces imaging time and enables acquisition of full retinal volumes in infants. The 110° field of view is provided via a re-usable contact lens that can be sterilized between imaging sessions.
Investigational noncontact OCT system:
The investigational noncontact handheld OCT systems in this study is developed at Duke University as the result of collaboration between the Departments of Ophthalmology (Cynthia Toth, MD) and Biomedical Engineering (Joseph Izatt, PhD). This investigational device was previously reviewed and approved for use in adults, children, and neonates in nursery by:
* Intraoperative OCT Guidance of Intraocular Surgery study's (Pro00016827) Data Safety and Monitoring Board Plus (DSMB+) (PI: Toth and Izatt)
* The Analyzing Retinal Microanatomy in Retinopathy of Prematurity to Improve Care study (Pro00069721) Data Safety and Monitoring Committee (DSMC) (PI: Toth) The systems were declared non-significant risk by the Duke University Health System (DUHS) Institutional Review Board under Pro00016827. Staff from the DUHS Clinical Engineering Department evaluated the systems and found that they meet the accepted hospital standards for electrical safety.
Pediatric participants
Pediatric patients with eye disease recruited from the patient population of Duke Eye Center (n=20)
Investigational contact OCT system
Theia imaging is developing handheld OCT systems bring state of the art OCT to the infant bedside. The Theia 1 widefield imaging system is a light weight, high speed (300 kHz), wide field of view (110°) OCT system that address the limitations of current commercial OCT systems. The system is cart mounted, enabling portable, bedside imaging. The system uses a 300 kHz swept source laser operating in 1060nm regime. The Theia system follows the same safety standards as all applicable laser safety standards (ANSI z80.36 or ISO 15004) as the currently approved prior OCT devices. This nearly 10-fold increase in acquisition speed dramatically reduces imaging time and enables acquisition of full retinal volumes in infants. The 110° field of view is provided via a re-usable contact lens that can be sterilized between imaging sessions.
Investigational noncontact OCT system:
The investigational noncontact handheld OCT systems in this study is developed at Duke University as the result of collaboration between the Departments of Ophthalmology (Cynthia Toth, MD) and Biomedical Engineering (Joseph Izatt, PhD). This investigational device was previously reviewed and approved for use in adults, children, and neonates in nursery by:
* Intraoperative OCT Guidance of Intraocular Surgery study's (Pro00016827) Data Safety and Monitoring Board Plus (DSMB+) (PI: Toth and Izatt)
* The Analyzing Retinal Microanatomy in Retinopathy of Prematurity to Improve Care study (Pro00069721) Data Safety and Monitoring Committee (DSMC) (PI: Toth) The systems were declared non-significant risk by the Duke University Health System (DUHS) Institutional Review Board under Pro00016827. Staff from the DUHS Clinical Engineering Department evaluated the systems and found that they meet the accepted hospital standards for electrical safety.
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
Investigational contact OCT system
Theia imaging is developing handheld OCT systems bring state of the art OCT to the infant bedside. The Theia 1 widefield imaging system is a light weight, high speed (300 kHz), wide field of view (110°) OCT system that address the limitations of current commercial OCT systems. The system is cart mounted, enabling portable, bedside imaging. The system uses a 300 kHz swept source laser operating in 1060nm regime. The Theia system follows the same safety standards as all applicable laser safety standards (ANSI z80.36 or ISO 15004) as the currently approved prior OCT devices. This nearly 10-fold increase in acquisition speed dramatically reduces imaging time and enables acquisition of full retinal volumes in infants. The 110° field of view is provided via a re-usable contact lens that can be sterilized between imaging sessions.
Investigational noncontact OCT system:
The investigational noncontact handheld OCT systems in this study is developed at Duke University as the result of collaboration between the Departments of Ophthalmology (Cynthia Toth, MD) and Biomedical Engineering (Joseph Izatt, PhD). This investigational device was previously reviewed and approved for use in adults, children, and neonates in nursery by:
* Intraoperative OCT Guidance of Intraocular Surgery study's (Pro00016827) Data Safety and Monitoring Board Plus (DSMB+) (PI: Toth and Izatt)
* The Analyzing Retinal Microanatomy in Retinopathy of Prematurity to Improve Care study (Pro00069721) Data Safety and Monitoring Committee (DSMC) (PI: Toth) The systems were declared non-significant risk by the Duke University Health System (DUHS) Institutional Review Board under Pro00016827. Staff from the DUHS Clinical Engineering Department evaluated the systems and found that they meet the accepted hospital standards for electrical safety.
Other Intervention Names
Discover alternative or legacy names that may be used to describe the listed interventions across different sources.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
* Subject is able and willing to consent to study participation
* Subject is more than 18 years of age
* Healthy adult volunteers without known ocular issues other than refractive error
* Pregnancy Reasonably Excluded Guide (PREG) evaluation on women of childbearing potential
* Group 2 - Pediatric participants
* Health care provider, knowledgeable of protocol, agrees that study personnel could contact the parent/legal guardian
* Parent/legal guardian is able and willing to consent to study participation
* Pediatric patient less than 18 years of age in Duke Eye Center ophthalmology clinics or undergoing clinically-indicated examination under anesthesia at Duke Eye Center
Exclusion Criteria
* Students or employees under direct supervision of the investigators
* Subjects with prior problems with pupil dilation
* Pregnant woman if receiving dilating drops
* Group 2 - Pediatric participants
* Parent/legal guardian unwilling or unable to provide consent
* Participant has a health or eye condition that preclude eye examination or retinal imaging (such as corneal opacity or cataract)
ALL
Yes
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Duke University
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Duke University Eye Center
Durham, North Carolina, United States
Countries
Review the countries where the study has at least one active or historical site.
Central Contacts
Reach out to these primary contacts for questions about participation or study logistics.
Facility Contacts
Find local site contact details for specific facilities participating in the trial.
References
Explore related publications, articles, or registry entries linked to this study.
Scott AW, Farsiu S, Enyedi LB, Wallace DK, Toth CA. Imaging the infant retina with a hand-held spectral-domain optical coherence tomography device. Am J Ophthalmol. 2009 Feb;147(2):364-373.e2. doi: 10.1016/j.ajo.2008.08.010. Epub 2008 Oct 9.
Chavala SH, Farsiu S, Maldonado R, Wallace DK, Freedman SF, Toth CA. Insights into advanced retinopathy of prematurity using handheld spectral domain optical coherence tomography imaging. Ophthalmology. 2009 Dec;116(12):2448-56. doi: 10.1016/j.ophtha.2009.06.003. Epub 2009 Sep 18.
Maldonado RS, Izatt JA, Sarin N, Wallace DK, Freedman S, Cotten CM, Toth CA. Optimizing hand-held spectral domain optical coherence tomography imaging for neonates, infants, and children. Invest Ophthalmol Vis Sci. 2010 May;51(5):2678-85. doi: 10.1167/iovs.09-4403. Epub 2010 Jan 13.
Maldonado RS, Freedman SF, Cotten CM, Ferranti JM, Toth CA. Reversible retinal edema in an infant with neonatal hemochromatosis and liver failure. J AAPOS. 2011 Feb;15(1):91-3. doi: 10.1016/j.jaapos.2010.11.016.
Maldonado RS, O'Connell R, Ascher SB, Sarin N, Freedman SF, Wallace DK, Chiu SJ, Farsiu S, Cotten M, Toth CA. Spectral-domain optical coherence tomographic assessment of severity of cystoid macular edema in retinopathy of prematurity. Arch Ophthalmol. 2012 May;130(5):569-78. doi: 10.1001/archopthalmol.2011.1846.
Chen X, Mangalesh S, Dandridge A, Tran-Viet D, Wallace DK, Freedman SF, Toth CA. Spectral-Domain OCT Findings of Retinal Vascular-Avascular Junction in Infants with Retinopathy of Prematurity. Ophthalmol Retina. 2018 Sep;2(9):963-971. doi: 10.1016/j.oret.2018.02.001. Epub 2018 Mar 21.
Chen X, Prakalapakorn SG, Freedman SF, Vajzovic L, Toth CA. Differentiating Retinal Detachment and Retinoschisis Using Handheld Optical Coherence Tomography in Stage 4 Retinopathy of Prematurity. JAMA Ophthalmol. 2020 Jan 1;138(1):81-85. doi: 10.1001/jamaophthalmol.2019.4796.
Mangalesh S, Bleicher ID, Chen X, Viehland C, LaRocca F, Izatt JA, Freedman SF, Hartnett ME, Toth CA. Three-dimensional pattern of extraretinal neovascular development in retinopathy of prematurity. Graefes Arch Clin Exp Ophthalmol. 2019 Apr;257(4):677-688. doi: 10.1007/s00417-019-04274-6. Epub 2019 Feb 21.
Mangalesh S, Sarin N, McGeehan B, Prakalapakorn SG, Tran-Viet D, Cotten CM, Freedman SF, Maguire MG, Toth CA; BabySTEPS Group. Preterm Infant Stress During Handheld Optical Coherence Tomography vs Binocular Indirect Ophthalmoscopy Examination for Retinopathy of Prematurity. JAMA Ophthalmol. 2021 May 1;139(5):567-574. doi: 10.1001/jamaophthalmol.2021.0377.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
Pro00113627
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.