Widefield Confocal Scanning Laser Ophthalmoscope Optimized for Pediatric and Neonatal Imaging

NCT ID: NCT06177639

Last Updated: 2025-10-08

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

RECRUITING

Total Enrollment

42 participants

Study Classification

OBSERVATIONAL

Study Start Date

2025-10-01

Study Completion Date

2026-08-31

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

The goal of this observational study is to test the use of a novel Widefield Confocal Scanning Laser Ophthalmoscope (WiSLO) Optimized for Pediatric and Neonatal Imaging in pediatric and adult subjects who are undergoing clinical evaluation for eye disease or are healthy adult volunteers.

The main questions to answer are:

* Whether WiSLO will be more comfortable and satisfactory in experience for the patient and operator than commercial alternatives.
* If the quality of WiSLO near infrared images will be comparable to color fundus camera imaging across population of different ages and fundus pigmentation.

Participants will have the following research procedures:

* Imaging of both eyes with a research noncontact WiSLO
* Imaging of both eyes with a commercially available non-contact hand held fundus camera (Volk Pictor Plus)
* Likert scales for adults
* Pediatric Likert scales for children
* CRIES scales for infants.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

The Widefield Confocal Scanning Laser Ophthalmoscope (WiSLO) Optimized for Pediatric and Neonatal Imaging study brings together a cross-disciplinary team of biomedical engineers and ophthalmologists to obtain feedback about and evaluate image quality of a handheld scanning laser ophthalmoscope (SLO) device designed and developed at Duke Biomedical Engineering under this grant specifically for portable pediatric and neonatal imaging applications which are not accessible by these populations. The expected outcome of the grant work is a validated design for a cost-scalable, dual-mode, widefield SLO (WiSLO) that produces NIR images comparable to existing color fundus cameras. The goal of this human subjects research is to gather initial supporting clinical data. Positive results from this initial study will motivate future technological refinement and clinical validation, ultimately leading to the commercialization of a technology that will greatly improve the standard of care in pediatric retinal imaging.

The investigators will recruit up to 42 participants into this study. This study will include enrollment of both pediatric and adult subjects who are undergoing clinical evaluation for eye disease or are healthy adult volunteers. Adult patients from Duke Eye Center Clinic with retinal findings will include for example, diabetic retinopathy, macular lesions, peripheral retinal lesions; Pediatric patients will have retinal findings including, for example: ROP, Coats disease, retinoschisis, familial exudative vitreoretinopathy, retinal detachment, retinal hemorrhages, retinoblastoma, and other lesions, or may have a normal retinal exam.

Participants will have the following research procedures: imaging of both eyes with (1) a research noncontact WiSLO and with a commercially available non-contact hand held fundus camera (Volk Pictor Plus), pen light evaluation of pupil size, sterile single use lubricating tear drops may be used, and Likert scales for adults, pediatric Likert scales for children and CRIES scales for infants. The adult cohort will complete imaging and analysis prior to start of pediatric imaging. Milestones of acceptable comfort with WiSLO imaging must be met from the adult analysis prior to imaging in pediatric participants.

Descriptive statistics will be computed for all retinal imaging variables (medians, means, standard deviations and ranges for continuous variables, and frequencies and percentages for categorical and binary variables). The significance of difference between imaging devices by eye for continuous variables (e.g. field of view, extent of each respective feature \[from overlay with conventional image as reference standard\], time to image), categorical variables (e.g. quality ratings) and binary variables (e.g. visualized yes or no) will be assessed using paired statistical tests (t-test or Wilcoxon signed rank test or McNemar's test, respectively). Comfort milestone prior to pediatric use: At least 8 of 10 adult participants must rate WiSLO imaging of equal or better comfort, and at least 5 of the participants must rate WiSLO better than the commercial handheld fundus camera. Further, the variabilities of results in use of the WiSLO versus commercial imaging systems will be contrasted. The relationships between WiSLO image findings vs color photograph findings and fundus pigmentation, age and other biological variables will be assessed graphically with scatterplots. Corresponding correlations will be computed to probe any associations between these biological measures and imaging outcomes.

Risks: There are no additional risks to participants beyond what is normal for standard ocular visualization and photographic procedures. Pharmacological pupil dilation will not be performed for research purposes.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Eye Diseases

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Observational Model Type

COHORT

Study Time Perspective

PROSPECTIVE

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

Adult (≥18 years) cohort

Adults that may or may not have eye pathology

WiSLO

Intervention Type DEVICE

Imaging with the research WiSLO device in non-contact mode (4 images from each eye)

Volk Pictor Plus™

Intervention Type DEVICE

Imaging with the commercial handheld fundus camera, Volk Pictor Plus™ (4 images from each eye)

Minor cohort

Infant/child undergoing clinically-indicated examination that may or may not have eye pathology. We will not enroll inpatient pre-term infants or neonates. The youngest age at enrollment will be 30 days adjusted age using the NICH NRN Web-based Adjusted Age Calculator.

WiSLO

Intervention Type DEVICE

Imaging with the research WiSLO device in non-contact mode (4 images from each eye)

Volk Pictor Plus™

Intervention Type DEVICE

Imaging with the commercial handheld fundus camera, Volk Pictor Plus™ (4 images from each eye)

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

WiSLO

Imaging with the research WiSLO device in non-contact mode (4 images from each eye)

Intervention Type DEVICE

Volk Pictor Plus™

Imaging with the commercial handheld fundus camera, Volk Pictor Plus™ (4 images from each eye)

Intervention Type DEVICE

Other Intervention Names

Discover alternative or legacy names that may be used to describe the listed interventions across different sources.

Widefield scanning laser ophthalmoscope

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

* Adults (≥18 years) that may or may not have eye pathology
* Infant/child undergoing clinically-indicated examination that may or may not have eye pathology. NOTE: We will not enroll inpatient pre-term infants or neonates. The youngest age at enrollment will be 30 days adjusted age using the NICH NRN Web-based Adjusted Age Calculator.
* Adults and infant/child with or without prior pupil dilation for clinical eye care visit
* Adult participant is able and willing to consent to study participation
* Parent/Legal Guardian is able and willing to consent to study participation for the minor
* Pediatric participant \>12 years is able and willing to assent to study participation

Exclusion Criteria

* Participant or Parent/Legal Guardian unwilling or unable to provide consent
* Participant has a health or eye condition that would preclude eye examination or retinal imaging (e.g. evidence of inflammation or infection of ocular surface or eyelids, or corneal opacity or cataract)
Minimum Eligible Age

30 Days

Eligible Sex

ALL

Accepts Healthy Volunteers

Yes

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

National Eye Institute (NEI)

NIH

Sponsor Role collaborator

Duke University

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Responsibility Role SPONSOR

Principal Investigators

Learn about the lead researchers overseeing the trial and their institutional affiliations.

Cynthia A Toth, MD

Role: PRINCIPAL_INVESTIGATOR

Duke University Eye Center

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

Duke University Eye Center

Durham, North Carolina, United States

Site Status RECRUITING

Countries

Review the countries where the study has at least one active or historical site.

United States

Central Contacts

Reach out to these primary contacts for questions about participation or study logistics.

Cynthia A Toth, MD

Role: CONTACT

(919) 684-9170

Michelle N McCall, MCAPM, BA

Role: CONTACT

(919) 684-0544

Facility Contacts

Find local site contact details for specific facilities participating in the trial.

Michelle McCall

Role: primary

919-684-0544

Neeru Sarin

Role: backup

9196685641

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

R21EY033515

Identifier Type: NIH

Identifier Source: secondary_id

View Link

Pro00111358

Identifier Type: -

Identifier Source: org_study_id

More Related Trials

Additional clinical trials that may be relevant based on similarity analysis.

Photoscreening for Retinoblastoma
NCT04344652 WITHDRAWN NA