Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
WITHDRAWN
PHASE4
INTERVENTIONAL
2024-05-01
2025-11-30
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Micra Transcatheter Pacing Study
NCT02004873
Accelerometer Sensing for Micra AV Study
NCT04245345
Micra Transcatheter Pacing System Continued Access Study Protocol
NCT02488681
Optimal Pacing Rate for Cardiac Resynchronization Therapy
NCT06445439
Home-Based Exercise Program Using Mobile Technology After Left Ventricular Assist Device Implantation
NCT06291922
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
After enrollment, the following baseline information will be assimilated from the medical record and will be collected if not already done based on routine clinical care: date of pacemaker implant, pacemaker implant location (high septum, mid septum, apex), cardiac disease history, and programmed pacemaker parameters.
Exercise testing will be performed between one week and six months after Micra AV implant. Participants will complete preparation for exercise testing according to institutional standards. Participants will be given instructions to take all prescribed medications, including antiarrhythmic drugs and AV nodal blocking agents, according to their usual schedule, including on the day of the test.
Participants will be provided with a holter monitor. Participants will begin wearing the monitor during the rest period at the start of the exercise testing protocol. Exercise testing will be completed using standardized Micra AV device programming settings: VDD mode with nominal maximal tracking rate. Auto programming will be used to initialize device parameter selection. Following completion of auto programming, a MAM test will be performed to assess atrial signal discrimination. A fixed A3 discrimination threshold will then be selected which is approximately 1.0 m/s2 greater than the isolated accelerometer A3 signal.10 Other sensing parameters will be adjusted as clinically indicated to optimize atrial signal discrimination. Each participant will undergo device monitoring accompanied by external telemetry for 20 minutes at rest, followed by a fitness level-appropriate standardized stress protocol (e.g., Bruce protocol, Naughton protocol, Eckland protocol) on the treadmill or recumbent bicycle. They will perform graded exercise until achieving a heart rate of 130 bpm, or until physical fatigue, limiting chest pain (or discomfort), marked ischemia, or a drop in blood pressure occur (if such symptoms develop prior to reaching the target heart rate), supervised by a clinician experienced in performing cardiac stress testing. Once reaching 130 bpm, participants will remain at the current stage on their exercise protocol until physical fatigue, limiting chest pain (or discomfort), marked ischemia, or a drop in blood pressure occurs, or up to a maximum of twenty total minutes of exercise. Participants will be asked to report level of perceived exertion and fatigue level at pre-determined intervals. Cardiac rhythm will be recorded using 12-lead telemetry throughout the rest, exercise, and recovery periods. If the tracking index during exercise is lower than 70%, atrial sensing will be optimized using a MAM test.
The following data will be collected during exercise testing: exercise protocol utilized, protocol stage achieved, baseline cardiac rhythm, characterization of atrial and/or ventricular tachyarrhythmias, resting heart rate, peak heart rate, peak blood pressure, perceived level of exertion and fatigue, total exercise time, total metabolic equivalents (METs) achieved, and reason for termination.
The following data will be abstracted from device interrogation and 12-lead telemetry following the test: total number of sinus atrial beats, total number of premature atrial complexes (PAC), total number of premature ventricular complexes (PVC), number of tracked events, number of non-tracked ventricular paced events, and number of ventricular beats resulting from native AV conduction. Participants will continue to wear the provided holter monitor for the remainder of the 24 hour period. The following data will be collected during holter monitoring: average heart rate, peak heart rate, minimum heart rate, characterization of atrial and/or ventricular tachyarrhythmias, total number of sinus atrial beats, total number of premature atrial complexes (PAC), total number of premature ventricular complexes (PVC), number of tracked events, number of non-tracked ventricular paced events, and number of ventricular beats resulting from native AV conduction. Patient charts will be reviewed at the time of study completion to report clinical outcomes including death, device extraction, and/or transition to a transvenous pacing system.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
NA
SINGLE_GROUP
OTHER
NONE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
Micra AV Exercise Testing
All participants will have Micra AV 2.0 implanted then undergo exercise testing while wearing Holter Monitor
Medtronic Micra AV Device
Participants will already be planned to have a Micra AV 2.0 device implanted. Participants will then undergo treadmill exercise testing and wear a Holter monitor to determine the effectiveness of the Micra AV 2.0 device during exercise or elevated heart rates.
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
Medtronic Micra AV Device
Participants will already be planned to have a Micra AV 2.0 device implanted. Participants will then undergo treadmill exercise testing and wear a Holter monitor to determine the effectiveness of the Micra AV 2.0 device during exercise or elevated heart rates.
Other Intervention Names
Discover alternative or legacy names that may be used to describe the listed interventions across different sources.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
* Written informed consent
* Presence of a Micra AV leadless pacemaker with the Micra AV 2.0 algorithm and at least 50% RV pacing
* High grade atrioventricular heart block as the primary indication for permanent pacing
* Sinus rhythm
* Physical ability to walk on a treadmill or ride a recumbent bicycle for exercise testing
Exclusion Criteria
* Intact atrioventricular conduction
* Persistent atrial fibrillation
* Those with absolute contraindications to exercise testing:
* Acute myocardial infarction (MI) within 2 days
* Ongoing unstable angina
* Uncontrolled cardiac arrhythmia with hemodynamic compromise
* Active endocarditis
* Symptomatic severe aortic stenosis
* Decompensated heart failure
* Acute pulmonary embolism, pulmonary infarction, or deep vein thrombosis
* Acute myocarditis or pericarditis
* Acute aortic dissection
* Physical disability that precludes safe and adequate testing
* Inability to consent
* Patient refusal to participate
* Pregnant patients
18 Years
ALL
Yes
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Duke University
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
Camille Frazier-Mills
Role: PRINCIPAL_INVESTIGATOR
Duke Medicine - Cardiology
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Duke University Health System
Durham, North Carolina, United States
Countries
Review the countries where the study has at least one active or historical site.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
Pro00112840
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.