Micra AV Tracking During Exercise Testing

NCT ID: NCT05966168

Last Updated: 2024-04-17

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

WITHDRAWN

Clinical Phase

PHASE4

Study Classification

INTERVENTIONAL

Study Start Date

2024-05-01

Study Completion Date

2025-11-30

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

The purpose of this study is to determine the effectiveness of the Micra AV 2.0 device during exercise or elevated heart rates. Participation in research studies is voluntary. In this study, participants will already be planned to have a Micra AV 2.0 device implanted. Participants will then undergo treadmill exercise testing and wear a Holter monitor. For each participant, the tracking performance of the Micra AV 2.0 will be evaluated at rest and during exercise. Follow up visits will occur as part of standard of care and each participant will be enrolled in the study for up to 6 months.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

Participants will be screened and eligible participants who express informed consent will complete exercise testing and holter monitoring. For each participant, the tracking performance of the atrial mechanically sensed, ventricular pacing device will be assessed at rest and during exercise using exercise testing. For each test, the sinus rate trend will be recorded alongside the presence or absence of a mechanically sensed ventricular paced event (AM-VP) for each sinus beat. The average tracking index in each phase of exercise testing - rest, exercise, and recovery - and across the spectrum of achieved heart rates across the cohort will be calculated and reported. Holter monitoring will also be used to assess tracking index across the spectrum of heart rates achieved during routine daily activities across a 24 hour period.

After enrollment, the following baseline information will be assimilated from the medical record and will be collected if not already done based on routine clinical care: date of pacemaker implant, pacemaker implant location (high septum, mid septum, apex), cardiac disease history, and programmed pacemaker parameters.

Exercise testing will be performed between one week and six months after Micra AV implant. Participants will complete preparation for exercise testing according to institutional standards. Participants will be given instructions to take all prescribed medications, including antiarrhythmic drugs and AV nodal blocking agents, according to their usual schedule, including on the day of the test.

Participants will be provided with a holter monitor. Participants will begin wearing the monitor during the rest period at the start of the exercise testing protocol. Exercise testing will be completed using standardized Micra AV device programming settings: VDD mode with nominal maximal tracking rate. Auto programming will be used to initialize device parameter selection. Following completion of auto programming, a MAM test will be performed to assess atrial signal discrimination. A fixed A3 discrimination threshold will then be selected which is approximately 1.0 m/s2 greater than the isolated accelerometer A3 signal.10 Other sensing parameters will be adjusted as clinically indicated to optimize atrial signal discrimination. Each participant will undergo device monitoring accompanied by external telemetry for 20 minutes at rest, followed by a fitness level-appropriate standardized stress protocol (e.g., Bruce protocol, Naughton protocol, Eckland protocol) on the treadmill or recumbent bicycle. They will perform graded exercise until achieving a heart rate of 130 bpm, or until physical fatigue, limiting chest pain (or discomfort), marked ischemia, or a drop in blood pressure occur (if such symptoms develop prior to reaching the target heart rate), supervised by a clinician experienced in performing cardiac stress testing. Once reaching 130 bpm, participants will remain at the current stage on their exercise protocol until physical fatigue, limiting chest pain (or discomfort), marked ischemia, or a drop in blood pressure occurs, or up to a maximum of twenty total minutes of exercise. Participants will be asked to report level of perceived exertion and fatigue level at pre-determined intervals. Cardiac rhythm will be recorded using 12-lead telemetry throughout the rest, exercise, and recovery periods. If the tracking index during exercise is lower than 70%, atrial sensing will be optimized using a MAM test.

The following data will be collected during exercise testing: exercise protocol utilized, protocol stage achieved, baseline cardiac rhythm, characterization of atrial and/or ventricular tachyarrhythmias, resting heart rate, peak heart rate, peak blood pressure, perceived level of exertion and fatigue, total exercise time, total metabolic equivalents (METs) achieved, and reason for termination.

The following data will be abstracted from device interrogation and 12-lead telemetry following the test: total number of sinus atrial beats, total number of premature atrial complexes (PAC), total number of premature ventricular complexes (PVC), number of tracked events, number of non-tracked ventricular paced events, and number of ventricular beats resulting from native AV conduction. Participants will continue to wear the provided holter monitor for the remainder of the 24 hour period. The following data will be collected during holter monitoring: average heart rate, peak heart rate, minimum heart rate, characterization of atrial and/or ventricular tachyarrhythmias, total number of sinus atrial beats, total number of premature atrial complexes (PAC), total number of premature ventricular complexes (PVC), number of tracked events, number of non-tracked ventricular paced events, and number of ventricular beats resulting from native AV conduction. Patient charts will be reviewed at the time of study completion to report clinical outcomes including death, device extraction, and/or transition to a transvenous pacing system.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Heart Block AV

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Allocation Method

NA

Intervention Model

SINGLE_GROUP

Primary Study Purpose

OTHER

Blinding Strategy

NONE

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

Micra AV Exercise Testing

All participants will have Micra AV 2.0 implanted then undergo exercise testing while wearing Holter Monitor

Group Type EXPERIMENTAL

Medtronic Micra AV Device

Intervention Type DEVICE

Participants will already be planned to have a Micra AV 2.0 device implanted. Participants will then undergo treadmill exercise testing and wear a Holter monitor to determine the effectiveness of the Micra AV 2.0 device during exercise or elevated heart rates.

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

Medtronic Micra AV Device

Participants will already be planned to have a Micra AV 2.0 device implanted. Participants will then undergo treadmill exercise testing and wear a Holter monitor to determine the effectiveness of the Micra AV 2.0 device during exercise or elevated heart rates.

Intervention Type DEVICE

Other Intervention Names

Discover alternative or legacy names that may be used to describe the listed interventions across different sources.

Micra AV Tracking During Exercise

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

* Age ≥18
* Written informed consent
* Presence of a Micra AV leadless pacemaker with the Micra AV 2.0 algorithm and at least 50% RV pacing
* High grade atrioventricular heart block as the primary indication for permanent pacing
* Sinus rhythm
* Physical ability to walk on a treadmill or ride a recumbent bicycle for exercise testing

Exclusion Criteria

* Earlier version of the Micra leadless pacemaker
* Intact atrioventricular conduction
* Persistent atrial fibrillation
* Those with absolute contraindications to exercise testing:
* Acute myocardial infarction (MI) within 2 days
* Ongoing unstable angina
* Uncontrolled cardiac arrhythmia with hemodynamic compromise
* Active endocarditis
* Symptomatic severe aortic stenosis
* Decompensated heart failure
* Acute pulmonary embolism, pulmonary infarction, or deep vein thrombosis
* Acute myocarditis or pericarditis
* Acute aortic dissection
* Physical disability that precludes safe and adequate testing
* Inability to consent
* Patient refusal to participate
* Pregnant patients
Minimum Eligible Age

18 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

Yes

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

Duke University

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Responsibility Role SPONSOR

Principal Investigators

Learn about the lead researchers overseeing the trial and their institutional affiliations.

Camille Frazier-Mills

Role: PRINCIPAL_INVESTIGATOR

Duke Medicine - Cardiology

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

Duke University Health System

Durham, North Carolina, United States

Site Status

Countries

Review the countries where the study has at least one active or historical site.

United States

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

Pro00112840

Identifier Type: -

Identifier Source: org_study_id