Air Leak Detection and Treatment

NCT ID: NCT05854654

Last Updated: 2024-07-16

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

RECRUITING

Clinical Phase

NA

Total Enrollment

200 participants

Study Classification

INTERVENTIONAL

Study Start Date

2023-05-02

Study Completion Date

2027-04-01

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

Developing a methodology to detect, quantify and treat air leaks intraoperatively using a bio-adhesive, to thereby reduce postoperative surgical complications, morbidity, and length of stay for patients undergoing pulmonary resection.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

This study aims at establishing a standardized, stable and effective ex-vivo human lung model, applying some changes to settings used in our previous studies both in animal and human models performed in this institution. Multiple procedures will be performed to each model in order to accomplish the objectives of the study. Tissue samples will be taken from the models and images will be performed. This will allow us to determine which configuration is the optimal for obtaining the more effective and stable models that could offer the best quality specimens as well. Lungs from patients undergoing lung transplantation after their removal from the recipient patient with previous informed consent signed before transplantation will be obtained. The organs will be placed in an acrylic box and will be kept at a temperature of 37 Celsius degrees. The lungs will be mechanically ventilated connected by an endotracheal tube size 8 inserted in the bronchus with the balloon inflated and a silk suture providing an hermetic closure proximal to the balloon. Alternatively, and as performed in one of our previous studies, according to the bronchial stump length and diameter, a Penrose drain (1 inch) will be sewn to the mainstem bronchus to simulate the trachea and allow for an endotracheal tube (ET), size 9.0 Fr, to be inserted into and secured with the Penrose drain. Following, a Sheridan® Sher-I-SWIV/FO ™ Double Swivel Connector will be inserted to the tube to allow performing endoscopic and RAB procedures while maintaining ventilation. The mechanical ventilator will be set using positive pressure and high tidal volume to prevent the lungs from collapsing.

A cannula will be placed in the pulmonary artery and secured with a purse-string suture. The lung will be perfused with 37°C solution using a roller pump (Terumo Sarns, Tokyo, Japan) with a flow rate (usually \~0.2 L/min) was adjusted to maintain a pulmonary arterial pressure of 10-12 mmHg to prevent hydrostatic pulmonary edema. The pulmonary veins will not be cannulated, allowing the perfusate to drain passively from the pulmonary veins into the reservoir at the base of the acrylic chamber from where it will be recycled through the pump. Temperatures of the lung tissue, ambient, container, and intravascular will be monitored by thermocouples. The pulmonary arterial pressure will be measured via a pulmonary arterial catheter (Cook, Bloomington, IN) placed in the circuit at the level of the left atrium. Once the model reaches a stable temperature 36°C, the procedures will begin.

This setting will allow us to perform several different endoscopic and RAB procedures in emulated physiologic conditions to complete the study.

In order to reproduce intraoperative air leaks, various manipulations, including stapling and creating lacerations of different depts and lengths on the parenchyma, will be performed on deflated lungs. Following the introduction of a leak, condensed gas will be pushed through the airway to precisely localize the defect. The sealant prepared at room temperature will then be applied in a thin layer to cover the defect and will be left to dry for 5 minutes. The seal will be tested using the condensed gas with the lung still deflated as well as with the water immersion technique after inflating the lung.

The leaks will be quantified using the Thopaz automated drainage system by Medela.

In order to test the long term stability of the matrix, the lung will be ventilated for X minutes. Air leak testing will be repeated at specific intervals during this time.

After all the procedures are finished and specimens obtained, all the lungs will be sent to the CHUM and will be processed following the standard hospital protocol for transplants recipients.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Air Leak From Lung

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Allocation Method

NA

Intervention Model

SINGLE_GROUP

Primary Study Purpose

DIAGNOSTIC

Blinding Strategy

NONE

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

Air Leaks

Lungs from patients undergoing lung transplantation after their removal from the recipient patient with previous informed consent signed before transplantation will be obtained. The organs will be placed in an acrylic box and will be kept at a temperature of 37 Celsius degrees. In order to reproduce intraoperative air leaks, various manipulations, including stapling and creating lacerations of different depts and lengths on the parenchyma, will be performed on deflated lungs. Following the introduction of a leak, condensed gas will be pushed through the airway to precisely localize the defect. The sealant prepared at room temperature will then be applied in a thin layer to cover the defect and will be left to dry for 5 minutes. The seal will be tested using the condensed gas with the lung still deflated as well as with the water immersion technique after inflating the lung.

Group Type EXPERIMENTAL

Air Leaks

Intervention Type DIAGNOSTIC_TEST

The organs will be placed in an acrylic box and will be kept at a temperature of 37 Celsius degrees. The lungs will be mechanically ventilated connected by an endotracheal tube size 8 inserted in the bronchus with the balloon inflated and a silk suture providing an hermetic closure proximal to the balloon.

This setting will allow us to perform several different endoscopic and RAB procedures in emulated physiologic conditions to complete the study.

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

Air Leaks

The organs will be placed in an acrylic box and will be kept at a temperature of 37 Celsius degrees. The lungs will be mechanically ventilated connected by an endotracheal tube size 8 inserted in the bronchus with the balloon inflated and a silk suture providing an hermetic closure proximal to the balloon.

This setting will allow us to perform several different endoscopic and RAB procedures in emulated physiologic conditions to complete the study.

Intervention Type DIAGNOSTIC_TEST

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

* Patients undergoing lung transplant surgery
* Organ donor ineligible to donate lungs

Exclusion Criteria

* Healthy individuals
Minimum Eligible Age

18 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

No

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

Centre hospitalier de l'Université de Montréal (CHUM)

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Responsibility Role SPONSOR

Principal Investigators

Learn about the lead researchers overseeing the trial and their institutional affiliations.

Moishe Liberman, MD

Role: PRINCIPAL_INVESTIGATOR

CHUM

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

CHUM

Montreal, Quebec, Canada

Site Status RECRUITING

Countries

Review the countries where the study has at least one active or historical site.

Canada

Central Contacts

Reach out to these primary contacts for questions about participation or study logistics.

Moishe Liberman, MD

Role: CONTACT

514-890-8000 ext. 26832

Facility Contacts

Find local site contact details for specific facilities participating in the trial.

Moishe Liberman, MD

Role: primary

514-890-8000 ext. 26832

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

2023-11357

Identifier Type: -

Identifier Source: org_study_id

More Related Trials

Additional clinical trials that may be relevant based on similarity analysis.

Intraoperative Air-Test
NCT03469648 COMPLETED