Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
In this study, the investigators will evaluate the efficacy of a novel adapter that avoids air leakage during bronchoscopy. Patients with respiratory failure on mechanical ventilation who require bronchoscopy will be randomized into two groups (groups A and B). These patients will be identified by the intensive care unit physician. Informed consent will be obtained from the patient's health care proxy. Patients in group A will undergo bronchoscopy using the standard commercially available adapter. Patients in group B will undergo bronchoscopy using the newly developed bronchoscope adapter. The efficacy of the bronchoscopy adapter will be evaluated by analyzing ventilator-associated parameters as well as the level of air contamination after the procedure. A bronchoscope adapter that limits air leak would have significant value in improving patient outcomes who receive bronchoscopy. Additionally, this would allow bronchoscopy to be more readily performed in patients with potential bacterial/viral pathogen spread.
Primary objective: Determination of equivalency or superiority of the new "leak-free adapter" compared to the standard commercial adapter to enable safe bronchoscopy in ventilated patients requiring bronchoscopy.
Secondary objective: To determine if the adapter provides improved ventilation during bronchoscopy by limiting tidal volume loss and pathogen aerosolization.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Evaluation of Leak-Free Bronchoscope Adapter to Limit Ventilated Air Volume Loss During Bronchoscopy
NCT06310577
Mask Leak With Nasal Cannula in Noninvasive Positive Pressure Ventilation
NCT02743936
Home Mechanical Ventilation Effectiveness and Air Leaks
NCT01090986
May Noninvasive Mechanical Ventilation (NIV) and/or Continuous Positive Airway Pressure (CPAP) Increase the Bronchoalveolar Lavage (BAL) Salvage in Patients With Pulmonary Diseases?
NCT05631132
Ventilation and Perfusion in the Respiratory System
NCT05081895
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
Mechanical ventilation requires endotracheal intubation (cannulation of the patient's trachea) to deliver ventilated air to the lungs. Air is delivered by the ventilator to the patient using positive pressure in a closed circuit, ensuring adequate tidal volume to the patient without air escape to the outside environment. Nevertheless, patients placed on mechanical ventilation often develop superimposed infections known as "Ventilator-Associated Pneumonia" (VAP) as well as significant mucus secretions which limit effective mechanical ventilation. A camera tipped device is used to enable more effective bronchoscopy to visualize and explore the tracheobronchial tree for both diagnostic (bacterial/viral sampling) and therapeutic (suctioning obstructive mucus secretions, delivery of therapeutic agents) purposes.
Despite clear diagnostic and therapeutic benefits, bronchoscopy is also associated with substantial morbidity and complications. To perform bronchoscopy, a standard (commercially available) adapter allows the bronchoscope to enter the closed ventilation circuit, providing direct access to the patient's airways. However, the standard adapter leads to a significant leak of tidal volume outside of the ventilation circuit to the ambient environment. This air leak from the adapter leads to two major complications: First, the loss of positive pressure ventilation to patients means that oxygen is not being delivered to the patient and therefore leads to hypoxemia, which limits the duration and efficacy of bronchoscopy. Second, escaped air from the ventilator circuit can lead to the generation of aerosols, which can lead to the significant spread of viral and bacterial infectious agents to the ambient environment and surrounding healthcare providers. Intensive care units (ICUs) in the US must employ negative pressure ventilation to limit pathogen spread outside of the room and to the rest of the ICU. ICU rooms equipped with standard room negative pressure ventilation require 46 minutes after bronchoscopy to clear 99% of aerosolized pathogens. Thus, despite the known diagnostic and therapeutic benefits of bronchoscopy, concerns surrounding viral exposure related to an air leak from bronchoscopy adapters led to the development of national guidelines that limited bronchoscopy in patients affected by Covid-19.
To overcome these limitations, the investigators developed a novel bronchoscope adapter capable of effectively limiting all tidal volume loss (i.e., air leak via adapter) associated with the currently available standard adapters. In ex-vivo and animal studies, the investigators noted that a significant portion of tidal volume delivered by the ventilator is lost to the ambient air when using the standard bronchoscope adapter using the standard adapter (\~40%). There was no tidal volume loss associated with the Leak-free bronchoscope adapter. The innovation in this adapter's development lies in the capacity to form an improved seal around the bronchoscope that limits tidal volume loss around the bronchoscope and captures air that escapes the circuit with the insertion and removal of the bronchoscope. Of note, the adapter is positioned outside the circuit and is only a conduit for the bronchoscope to enter the circuit.
Here the investigators propose a comparative effectiveness study that evaluates the leak-free bronchoscope adapter's use to enable bronchoscopy similar to the standard adapter. Additionally, the investigators will evaluate the adapter's capacity to deliver either equivalent tidal volume to the currently available adapter in patients undergoing bronchoscopy.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
RANDOMIZED
PARALLEL
SUPPORTIVE_CARE
DOUBLE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
Leak-free bronchoscope adapter
The mechanical ventilation circuit used in patients with respiratory failure is considered a closed-loop circuit between the patient and the ventilator. This allows air to flow from the ventilator to the patient and back to the circuit without escaping to the ambient environment. To perform bronchoscopy, a standard adapter is spliced into the ventilator circuit, which allows the bronchoscope to enter the ventilation circuit granting access to the patient's airways. This study will compare the efficacy of the standard commercially available adapter to the newly developed leak-free adapter. The intervention is considered the "leak-free bronchoscope adapter."
Leak-free Bronchoscope Adapter
A novel leak-free bronchoscope adapter will connect to the ventilation circuit in place of a standard adapter.
Standard bronchoscope adapter
The mechanical ventilation circuit used in patients with respiratory failure is considered a closed-loop circuit between the patient and the ventilator. This allows air to flow from the ventilator to the patient and back to the circuit without escaping to the ambient environment. To perform bronchoscopy, a standard adapter is spliced into the ventilator circuit, which allows the bronchoscope to enter the ventilation circuit granting access to the patient's airways. This study will compare the efficacy of the standard commercially available adapter to the newly developed leak-free adapter. This arm utilizes the standard adapter.
Standard Bronchoscope Adapter
Commercially available bronchoscope adapter (Smiths Medical)
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
Leak-free Bronchoscope Adapter
A novel leak-free bronchoscope adapter will connect to the ventilation circuit in place of a standard adapter.
Standard Bronchoscope Adapter
Commercially available bronchoscope adapter (Smiths Medical)
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Exclusion Criteria
3. Aged 18 years or above
The participant may not enter the study if ANY of the following apply:
1. Female participants who are pregnant during the study.
2. SpO2 (oxygen saturation) \< 90% at baseline.
3. The patient requires high ventilation requirements as indicated by a positive end-expiratory pressure (PEEP) greater than 20 mmHg or inspired oxygen requirements greater than 90%.
4. Hemodynamic instability requiring significant use of vasoactive pressors to maintain blood pressure.
5. Any other significant disease or disorder that, in the Investigator's opinion, may either put the participants at risk because of participation in the study or may influence the result of the study.
18 Years
ALL
Yes
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
State University of New York - Downstate Medical Center
OTHER
Columbia University
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Beth Hochman
Assistant Professor of Surgery (in Anesthesiology), Dept of Surgery Acute Care
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
Beth Hochman, MD
Role: PRINCIPAL_INVESTIGATOR
Columbia University
References
Explore related publications, articles, or registry entries linked to this study.
Wunsch H, Wagner J, Herlim M, Chong DH, Kramer AA, Halpern SD. ICU occupancy and mechanical ventilator use in the United States. Crit Care Med. 2013 Dec;41(12):2712-9. doi: 10.1097/CCM.0b013e318298a139.
Cummings MJ, Baldwin MR, Abrams D, Jacobson SD, Meyer BJ, Balough EM, Aaron JG, Claassen J, Rabbani LE, Hastie J, Hochman BR, Salazar-Schicchi J, Yip NH, Brodie D, O'Donnell MR. Epidemiology, clinical course, and outcomes of critically ill adults with COVID-19 in New York City: a prospective cohort study. Lancet. 2020 Jun 6;395(10239):1763-1770. doi: 10.1016/S0140-6736(20)31189-2. Epub 2020 May 19.
Kalanuria AA, Ziai W, Mirski M. Ventilator-associated pneumonia in the ICU. Crit Care. 2014 Mar 18;18(2):208. doi: 10.1186/cc13775. No abstract available.
Chhajed PN, Glanville AR. Management of hypoxemia during flexible bronchoscopy. Clin Chest Med. 2003 Sep;24(3):511-6. doi: 10.1016/s0272-5231(03)00050-9.
Tran K, Cimon K, Severn M, Pessoa-Silva CL, Conly J. Aerosol generating procedures and risk of transmission of acute respiratory infections to healthcare workers: a systematic review. PLoS One. 2012;7(4):e35797. doi: 10.1371/journal.pone.0035797. Epub 2012 Apr 26.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
AAAT3916
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.