Cardiac Output in Heart Failure Patients With Mechanical Pumps
NCT ID: NCT05195931
Last Updated: 2023-05-19
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
TERMINATED
7 participants
OBSERVATIONAL
2021-06-08
2022-08-25
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Acute Feedback on Left ventrIcular Lead Implantation Location for Cardiac Resynchronization Therapy
NCT01996397
Observational Hemodynamic Monitoring During LVAD Implantation Among Individuals With Advanced Heart Failure
NCT03464981
Cardiac Resynchronization Therapy (CRT) Based Heart Failure Monitoring Study
NCT00632372
A Pilot Study Comparing the Programmed Delay Between the Atrial and Ventricle Interval
NCT00794183
Pacing in Heart Failure With Preserved LVEF
NCT03215849
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
Heart failure patients suffer from persistent heart failure symptoms, and impairments in functional capacity, following LVAD implantation. It has previously been demonstrated that LVAD patients have severely reduced functional capacity, as measured by serial assessments of maximal oxygen uptake (VO2Max), greater than one year following device implantation.27 Specifically, VO2Max, when assessed before LVAD implantation, 3-6 months, 1 year, and greater than 1 year following device implantation, remains below 14ml/kg/min. Submaximal exercise, measured by six-minute hall walk (6MHW) scores, improves modestly following device implantation, but on average, remains severely reduced at approximately 300-350m, and similar to VO2Max values observed in these patients, falls within a range that is observed among patients with advanced HFrEF. About half of patients report persistence of HFrEF-related symptoms 6-12 months following device implantation. These persistent reductions in VO2Max, 6MHW, and HRqOL assessments all indicate that LVAD patients suffer from persistent heart failure, which manifests with attempts to exercise. For example, HFrEF patients are considered to be eligible for a heart transplantation when their VO2Max falls below 12-14ml/kg/min.
Impairments in HRqOL and functional capacity result from an inability of the LVAD to improve cardiovascular hemodynamics during exercise. To understand how LVADs influence cardiac filling pressures at rest and during exercise, we previously evaluated patients prior to, and following LVAD implantation by invasive cardiopulmonary exercise testing (CPET) with Swan-Ganz catheterization during upright cycle ergometry prior to and following LVAD implantation (COMIRB #16-1635). In this study (figure 2), three visits were completed: 1) Visit 1: baseline exercise assessment four weeks before LVAD implantation. 2) Visit 2: post-LVAD exercise assessment with patient exercising at constant LVAD pump speed. 3) Visit 3: post-LVAD exercise assessment but with stepwise increases in LVAD rotor speed during exercise, to determine whether additional flow through device improves exercise capacity. Several novel insights resulted from this work (figure 2):
1. Cardiopulmonary performance remains severely limited following device implantation. Compared to pre-LVAD CPET (visit 1), there is no improvement in VO2Max following LVAD implantation when patients exercise to volitional exhaustion at either a constant pump speed (visit 2), or with stepwise increases in pump speed (visit 3).
2. LVAD flow increases minimally during exercise. Regardless of whether LVAD patients exercise at a constant pump speed or with stepwise increases in speed, LVADs can only increase flow by approximately 1L/min above resting levels. As such, cardiac output during exercise - and hence, VO2Max - is determined by contractile reserve of the native ventricle, as opposed to the LVAD itself.
3. Exertional pulmonary arterial and cardiac filling pressures do not improve following LVAD implantation. Pre-implantation exertional filling pressures (visit 1) are severely elevated in the setting of advanced HFrEF, and interestingly, there is no substantive improvement following device implantation when exercising at a fixed LVAD speed or with stepwise increases in pump speed.
There is a paucity of data regarding the impact of changes in hemodynamics on LVAD function in the human body. The effects of alterations in afterload, preload and contractility in the normal heart are well described. For example, left ventricular (LV) pressure-volume analysis (the gold-standard metric of describing ventricular function) indicates that there is an inverse relationship between afterload and Qc, such that increases in afterload lead to reductions in Qc, and vice versa. However, preload is directly related to Qc, such that increases in cardiac preload lead to a rise in Qc through the Frank-Starling mechanism. In vitro studies of LVADs suggest that - at least in the controlled environment of a "mock-loop" (figure 3), LVADs have a reduced preload sensitivity than the normal heart. For example, LVAD preload sensitivity is approximately half the levels observed in the normal heart (LVAD v. heart, 0.105±0.092 v. 0.213±0.003 L/min/mmHg). However, similar mock-loop studies suggest that LVADs have a much higher afterload sensitivity - approximately three times - that of the normal heart (LVAD v. heart 0.09±0.034 v. 0.03±0.01 L/min/mmHg). The main limitation with these mock-loop studies, however, is that for variables such as preload and afterload, which all contribute to changes in flow - these variables are changed in isolation (e.g. increasing preload while holding afterload constant), whereas in the human body, all variables change simultaneously during activity. As such, these mock-loop studies do not adequately describe - or explain, LVAD flow behavior during exercise, where preload increases, afterload decreases, and contractility increases, but LVAD flow increases minimally or not at all (point #2 above). It has previously been emphasized that a detailed understanding of exercise physiology in this patient population is necessary to improve HRqOL and exercise tolerance in this patient population. Therefore, the primary objective of this study is to evaluate LVAD performance in response to alterations in loading conditions (preload, afterload, contractility) in HFrEF patients supported by these devices, and characterize the determinants of LVAD flow and Qc during activity/exercise.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
COHORT
PROSPECTIVE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
Preload and Afterload
10 participants with heart failure who are supported by LVADs will undergo hemodynamic monitoring and observation while undergoing changes in preload (head-up tilt and saline infusion), and afterload (nitroprusside and phenylephrine infusion).
preload challenge
reduction in preload by head-up tilt and increase in preload with saline infusion
afterload challenge
reduction in afterload with nitroprusside and increase in afterload with phenylephrine
Contractility
10 participants with heart failure who are supported by LVADs will undergo hemodynamic monitoring and observation while undergoing changes in contractility with adjustments in heart rate (by adjusting pacemaker), dobutamine infusion, and during exercise.
contractility assessment
heart rate changes will be made by increasing heart rate with external pacemaker/defibrillator. Contractility will be adjusted by dobutamine infusion. Patients will exercise at a constant pump speed and also with pump speed increases.
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
preload challenge
reduction in preload by head-up tilt and increase in preload with saline infusion
afterload challenge
reduction in afterload with nitroprusside and increase in afterload with phenylephrine
contractility assessment
heart rate changes will be made by increasing heart rate with external pacemaker/defibrillator. Contractility will be adjusted by dobutamine infusion. Patients will exercise at a constant pump speed and also with pump speed increases.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
2. Clinically stable, ambulatory outpatients with HVAD who are fully recovered from surgical implantation.
Exclusion Criteria
2. Clinical instability, defined as hypotension (mean arterial pressure \< 60mmHg and symptomatic, as measured in the advanced heart failure LVAD clinic), or hypertension (mean arterial pressure \> 90mmHg); patients with refractory heart failure symptoms with New York Heart Association functional classification IIIB or IV symptoms;
3. any chronic illness which would render the patient unable to complete the protocol as described, including but not limited to: moderate-severe osteoarthritis, severe pulmonary disease requiring supplemental oxygen, uncontrolled hypertension, a high baseline HVAD pump speed above 2860RPM (exercise protocol requires increasing pump speed by up to 240 RPM);
4. chronic kidney disease with a glomerular filtration rate \< 30ml/min/1.73m2;
5. absence of a pacemaker-defibrillator (necessary for pacing assessment as described below);
6. individuals with clinical evidence of right ventricular (RV) dysfunction/failure, defined as moderate-severe hypervolemia on physical examination with elevated jugular venous pressure greater than 10cmH20, imaging evidence of severe RV dysfunction by imaging assessment or tricuspid annular plane systolic excursion \< 17mmHg, or use of outpatient inotropes for known history of RV dysfunction.
18 Years
80 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
University of Colorado, Denver
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
University of Colorado Snschutz Medical Campus
Aurora, Colorado, United States
Countries
Review the countries where the study has at least one active or historical site.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
20-2143
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.