Heart Failure Study of Multi-site Pacing Effects on Ventriculoarterial Coupling

NCT ID: NCT03189368

Last Updated: 2020-09-11

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

COMPLETED

Total Enrollment

80 participants

Study Classification

OBSERVATIONAL

Study Start Date

2017-09-18

Study Completion Date

2020-09-01

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

To perform a comparative study of multi-site left ventricular pacing and cardiac resynchronization therapy effects on ventriculoarterial coupling and energy efficiency of the failing heart

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

Given that the main function of the cardiovascular system is to provide sufficient blood supply to tissues in order to ensure their normal and effective function, combined with the most efficient possible use of energy produced by ATP degradation, there has been a keen interest in elucidating the interplay between heart and vessels, critically affecting both.

In order to achieve these goals, it is thought that in healthy humans the cardiovascular system as a unity operates at a unique combination of parameters (arterial elastance, heart rate and left ventricular end systolic elastance) so as to:

1. Maximize stroke work (SW) for a given left ventricular contractility. This is related to the fact that adequate tissue perfusion is dependent both on stroke volume and on pressure and in fluid dynamics W=∆P×∆V (thus maximizing SW leads to optimal perfusion), OR
2. Optimize energy efficiency of the heart, in terms of energy transferred to the arterial bed to total mechanical energy.

Ventriculoarterial coupling (VAC) is a composite parameter, defined as the ratio of arterial elastance (Ea) to end systolic left ventricular elastance (Ees). Thus: VAC=Ea/Ees . It is a fundamental property of the cardiovascular system, integrating and assessing the interaction of all individual parameters of the ventricle (pump) and the arterial tree (afterload). Furthermore, VAC may assess both whether SW produced is maximal for a given contractility of the left ventricle (condition for maximization: VAC=1) and whether mechanical efficiency of the ventricle is optimal (optimization condition: VAC=0.5-0.7). Consequently, simultaneous optimization is not possible, and the cardiovascular system operates either at maximal output (as in healthy individuals at rest) or at optimal efficiency (healthy individuals at exercise). Multi-site pacing (MSP) of the left ventricle is a recently introduced technique with excellent studies' findings concerning echocardiographic parameters of ventricular function. Recently, the MultiPoint Pacing (MPP) IDE study showed that a specific choice of electrical dipole for the first left ventricular pulse and a close to simultaneous application of the two left ventricular pulses achieves a very high percent of clinical response (87%), with excellent patient safety. Subsequent studies confirmed these findings, reporting even higher NYHA response rates (95% vs 78% for conventional cardiac resynchronization therapy - CRT).

The underlying rationale lies in the better approximation of the normal sequence of left ventricular activation, through use of two, instead of a single, pulses. According to trial results, one can achieve, compared to conventional CRT, improved coordination between left ventricular segments, improved cardiac output and, possibly, tissue perfusion, and potentially reduction of arrhythmia propensity (mechanism similar to that of CRT). Thus, it would be interesting to study whether these can be independently confirmed by changes in VAC values. In heart failure, VAC values increase considerably due to increases in Ea as a result of the feedback loop regarding pressure (but not volume) maintenance. As a consequence, any reduction would move them closed to both 1 and the 0.5-0.7 area, yielding improvement in both SW maximization and efficiency optimization.

However, there are objective difficulties in achieving lege artis MSP (according to MPP-IDE study standards) given that two prerequisites must be met: 1. Interpolar distance for the first left ventricular pulse \>30mm (i.e. non-sequential poles used), 2. Nearly simultaneous (Δt=5msec) left ventricular pulses and 3. Threshold of ≤[email protected].

Moreover, the first pulse should, ideally, be directed to the most delayed, compared to the normal activation sequence, viable myocardial segment, a feat not always possible due to electrode placing constraints. Obviously, presence of scar could alter the course and shape of the activation front and thus diminish its effects (similar to issues already discussed in the case of CRT).

Objective:

To perform a comparative study of multi-site left ventricular pacing and cardiac resynchronization therapy effects on ventriculoarterial coupling and energy efficiency of the failing heart

Hypothesis:

VAC values are improved (shift closer to unity/0.5-0.7 area) and work/efficiency increase with patients on MSP as compared to CRT pacing.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Heart Failure

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Observational Model Type

CASE_CROSSOVER

Study Time Perspective

PROSPECTIVE

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

Heart failure patients eligible for CRT

Adult, consenting patients with any cardiomyopathy type and an existing I/IIa indication for a CRT-D device will receive a device with multi-site pacing capability. Initially, for 6 months, optimal, conventional, resynchronization therapy will be delivered. Following this, all patients will crossover to optimized multi-site pacing, and receive this therapy for 6 more months. Optimization of therapy will be determined based on maximization of cardiac output, i.e. maximization of left ventricular outflow tract velocity-time integral.

Baseline measurements of serum creatinine and ventriculoarterial coupling will also be acquired.

Activation of multi-site pacing capability on CRT devices

Intervention Type DEVICE

Instead of administering a single LV pulse at the most (electrically) delayed segment of the ventricle, multi-site pacing allows for a more detailed "sculpting" of the LV activation sequence. Based on the MPP-IDE study results, activation of the antero-lateral wall, or at least its most delayed segments, closely followed by a pulse to the apex and then by a right ventricular one will yield favorable results in terms of hemodynamics and clinical parameters.

Programming features:

* Interpolar distance for the first left ventricular pulse \>30mm (i.e. non-sequential poles used)
* Nearly simultaneous (Δt=5msec) second left ventricular pulse and
* Threshold of ≤[email protected]

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

Activation of multi-site pacing capability on CRT devices

Instead of administering a single LV pulse at the most (electrically) delayed segment of the ventricle, multi-site pacing allows for a more detailed "sculpting" of the LV activation sequence. Based on the MPP-IDE study results, activation of the antero-lateral wall, or at least its most delayed segments, closely followed by a pulse to the apex and then by a right ventricular one will yield favorable results in terms of hemodynamics and clinical parameters.

Programming features:

* Interpolar distance for the first left ventricular pulse \>30mm (i.e. non-sequential poles used)
* Nearly simultaneous (Δt=5msec) second left ventricular pulse and
* Threshold of ≤[email protected]

Intervention Type DEVICE

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

* Adult (\>18 years of age), consenting patients
* Any cardiomyopathy type and
* An existing I/IIa indication for a CRT-D device

Exclusion Criteria

* Those with a class IIb CRT indication
* Those where thresholds of \<[email protected] cannot be achieved in at least two dipoles of the left pacing electrode
* Those where no dipole with a distance between poles of 30mm can be detected
* Those with \>2/4 (moderate to severe - severe) mitral/aortic insufficiency, rendering noninvasive VAC calculation unreliable.
* Finally, contraindication to receiving intravenous paramagnetic contrast (gadolinium) will also constitute grounds for exclusion.
Minimum Eligible Age

18 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

No

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

National and Kapodistrian University of Athens

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Polychronis Dilaveris

Director of Cardiology, First Department of Cardiology, Hippokrateion General Hospital

Responsibility Role PRINCIPAL_INVESTIGATOR

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

First Department of Cardiology, Hippokration General Hospital

Athens, Attica, Greece

Site Status

Countries

Review the countries where the study has at least one active or historical site.

Greece

References

Explore related publications, articles, or registry entries linked to this study.

Chrysohoou C, Dilaveris P, Antoniou CK, Skiadas I, Konstantinou K, Gatzoulis K, Kallikazaros I, Tousoulis D. Heart failure study of multipoint pacing effects on ventriculoarterial coupling: Rationale and design of the HUMVEE trial. Ann Noninvasive Electrocardiol. 2018 May;23(3):e12510. doi: 10.1111/anec.12510. Epub 2017 Oct 15.

Reference Type DERIVED
PMID: 29034563 (View on PubMed)

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

HippoCT1

Identifier Type: -

Identifier Source: org_study_id

More Related Trials

Additional clinical trials that may be relevant based on similarity analysis.

Pacing in Heart Failure With Preserved LVEF
NCT03215849 ENROLLING_BY_INVITATION NA