Concordance Between the Systolic Foot-to-Apex Interval and the Auscultatory Method for Measuring Brachial Systolic Pressure in Pregnant Women With or Without Blood Pressure Disorders and Search for Markers of Arterial Stiffness in Pre-eclampsia.
NCT ID: NCT04943133
Last Updated: 2021-09-28
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
COMPLETED
NA
132 participants
INTERVENTIONAL
2021-01-22
2021-07-15
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Vascular Biomarkers Predictive of the Progression From Hypertensive Disorders in Pregnancy to Preeclampsia in Pregnant Women
NCT04520048
Comparison of Longitudinal Blood Pressure and Arterial Stiffness in Preeclamptic Women After Delivery
NCT04142268
Ambulatory Blood Pressure Monitoring in Post-Partum Pre-Eclamptic Patients
NCT02943122
Conical Forearm and Cylindrical Upper Arm Non-Invasive Blood Pressure (NIBP) Measurements in Pregnant Patients
NCT06466161
Central Blood Pressure
NCT03026010
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
However, the main difficulty lies in the unreliability of many measuring devices. One of the hypotheses that may explain this unreliability is that they are based on the analysis of the oscillometric curve. The latter is influenced by the behaviour of the arterial wall and its biomechanical properties. However, during normal pregnancy, arterial compliance is altered, particularly as a result of hypervolaemia. With hypertension and pre-eclampsia, these changes are even more pronounced.
The gold standard for measuring blood pressure remains the auscultatory method based on the detection of Korotkoff's sounds. Now, this method is being used less and less in favour of the oscillometric method and increasing use of automated devices.However, these automatons use algorithms that are neither revealed nor interchangeable and, despite them being CE marked, the majority of the devices on the market have not been validated by clinical trials in accordance with the recommendations. Validating them in pregnant women is even more problematic and it is generally accepted that most voltage measurement systems can be faulty. To improve the accuracy and reproducibility of the oscillometric method, we have developed a new algorithm for determining systolic blood pressure based on the oscillometric curve, involving a temporal analysis of the oscillometric curve, not its envelope. This original approach has made it possible to highlight an increase in the delay between the foot and the peak of the systolic peak of the oscillogram (SFATI - Systolic Foot-to-Apex Time Interval), the maximum value of which coincides with the first Korotkoff sound, thus allowing real measurement of systolic blood pressure for the first time, not just a calculation.
In addition, this parameter presents a second elevation, observed in the region of mean blood pressure in patients with cardiovascular risk factors and therefore at a risk of increased arterial stiffness. This parameter should make it possible to easily identify subjects with an arterial compliance disorder via a simple standard blood pressure measurement. This opens up many possibilities in terms of screening including on a large scale and repeated basis.
Thus, with a simple blood pressure measurement, the SFATI algorithm should make it possible to correct the inconsistencies observed with the conventional oscillometric method during pregnancy, with two advantages :
* precise, reliable blood pressure measurement ensuring not only the diagnosis of pre-eclampsia but also the quality of monitoring, which is a prerequisite for appropriate therapeutic management;
* evaluation of the vessel walls, by detecting possible stiffness, indicating arterial damage. The aim here is to characterise the curve profile obtained in women with pre-eclampsia, at various levels of severity and also to evaluate this profile in women with a history of pre-eclampsia or at risk of pre-eclampsia. The possible specificities would then make it possible to integrate this approach into the current screening strategy in order to evaluate its interest on a larger scale.
We therefore make the following assumptions :
1. the SFATI method is more reliable than the standard auscultatory method for accurately measuring brachial systolic blood pressure in pregnant women, whatever their blood pressure status;
2. in women with blood pressure disorders, the oscillometric curve is modified with the presence of arterial stiffness markers, making it possible to characterise a particular oscillometric profile.
3. this particular profile appears at an early stage and should make it possible to identify women at higher risk of developing pre-eclampsia.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
NON_RANDOMIZED
PARALLEL
PREVENTION
NONE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
3rd-term group: Pregnant women included in the last 3 months of pregnancy
Comparison of the profile of the curve according to whether there is presence or absence of blood pressure disorders.
Blood pressure measurement and collection of the oscillometric curve for later SFATI analysis
Brachial systolic arterial blood pressure will be systematically taken with acquisition of the oscillometric curve for analysis and measurement with the SFATI system and simultaneous electronic recording of the Korotkoff sound (auscultatory method) and a search for SFATI arterial stiffness markers for all patients. Brachial systolic arterial blood pressure will be measured with the help of a cuff equipped with a Biopac SS30L electronic stethoscope and a MA-300 phonocardiographic microphone, placed side-by-side immediately downstream from the brachial occlusion cuff. The various signals (pneumatic cuff, oscillometric signal and Korotkoff sounds) will be digitalized by an MP35 system.
Blood pressure measurement with the usual equipment used in the department
Brachial systolic blood pressure will be taken via the conventional oscillometric method, only for hospitalized women. Blood pressure will be measured on the same arm with the help of a conventional Dinamap-type automat (GE), with at least 2 minutes between the end of the first measurement and the start of the second inflation.
systematic measurement of pulse wave velocity (aortic and brachial)
Carotid to femoral and carotid to radial pulse wave velocity (Complior) will be systematically determined for hospitalized women and offered to all women seen for consultation.
Pulse wave velocity will be measured with the help of a Complior tonometric system (Alam Medical, Vincennes, France), with which the aorta and the arterial axes of the upper limb used to measure blood pressure can also be measured.
Before 20 weeks group. Pregnant women (normal blood pressure) included before 20 weeks of pregnancy.
Comparison of the profile of the curve according to the presence or absence of risk factors for pre-eclampsia
Blood pressure measurement and collection of the oscillometric curve for later SFATI analysis
Brachial systolic arterial blood pressure will be systematically taken with acquisition of the oscillometric curve for analysis and measurement with the SFATI system and simultaneous electronic recording of the Korotkoff sound (auscultatory method) and a search for SFATI arterial stiffness markers for all patients. Brachial systolic arterial blood pressure will be measured with the help of a cuff equipped with a Biopac SS30L electronic stethoscope and a MA-300 phonocardiographic microphone, placed side-by-side immediately downstream from the brachial occlusion cuff. The various signals (pneumatic cuff, oscillometric signal and Korotkoff sounds) will be digitalized by an MP35 system.
Blood pressure measurement with the usual equipment used in the department
Brachial systolic blood pressure will be taken via the conventional oscillometric method, only for hospitalized women. Blood pressure will be measured on the same arm with the help of a conventional Dinamap-type automat (GE), with at least 2 minutes between the end of the first measurement and the start of the second inflation.
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
Blood pressure measurement and collection of the oscillometric curve for later SFATI analysis
Brachial systolic arterial blood pressure will be systematically taken with acquisition of the oscillometric curve for analysis and measurement with the SFATI system and simultaneous electronic recording of the Korotkoff sound (auscultatory method) and a search for SFATI arterial stiffness markers for all patients. Brachial systolic arterial blood pressure will be measured with the help of a cuff equipped with a Biopac SS30L electronic stethoscope and a MA-300 phonocardiographic microphone, placed side-by-side immediately downstream from the brachial occlusion cuff. The various signals (pneumatic cuff, oscillometric signal and Korotkoff sounds) will be digitalized by an MP35 system.
Blood pressure measurement with the usual equipment used in the department
Brachial systolic blood pressure will be taken via the conventional oscillometric method, only for hospitalized women. Blood pressure will be measured on the same arm with the help of a conventional Dinamap-type automat (GE), with at least 2 minutes between the end of the first measurement and the start of the second inflation.
systematic measurement of pulse wave velocity (aortic and brachial)
Carotid to femoral and carotid to radial pulse wave velocity (Complior) will be systematically determined for hospitalized women and offered to all women seen for consultation.
Pulse wave velocity will be measured with the help of a Complior tonometric system (Alam Medical, Vincennes, France), with which the aorta and the arterial axes of the upper limb used to measure blood pressure can also be measured.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
* Patient has given written informed consent.
* Patient has signed the consent form.
* Patient is covered by a health insurance scheme.
* Patient is aged over 18.
Exclusion Criteria
* Patient is taking part in a category 1 research study.
* Patient is in a period of exclusion determined by another study.
* Patient is under legal protection or curatorship.
* Patient is in no condition to express her consent.
* Patient for whom it is impossible to give clear information.
18 Years
FEMALE
Yes
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Centre Hospitalier Universitaire de Nīmes
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Nîmes University Hospital
Nîmes, Gard, France
Countries
Review the countries where the study has at least one active or historical site.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
IDIL/2020/APM-001
Identifier Type: -
Identifier Source: org_study_id
More Related Trials