Trauma Study: Early Warning of Progression Toward Hemodynamic Deterioration After Trauma
NCT ID: NCT04912232
Last Updated: 2024-05-24
Study Results
Outcome measurements, participant flow, baseline characteristics, and adverse events have been published for this study.
View full resultsBasic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
TERMINATED
NA
1 participants
INTERVENTIONAL
2022-12-08
2022-12-08
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Early detection of ongoing hemorrhage (OH) before onset of shock is a universally acknowledged great unmet need, and particularly important after trauma. Delays in the detection of OH are associated with a "failure to rescue" and a dramatic deterioration in prognosis once the onset of clinically frank shock has occurred. An early alert to the presence of OH with an acceptable rate of false-positives and false-negatives would save countless lives. Additionally, such technology would save significant time, money and effort by allowing medical resources to be applied more accurately - the essence of precision medicine. An automated system would monitor currently stable patients continuously, leaving clinicians free to care for patients in need of attention.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
A 48 Subject Study Using Non-invasive Multi-Technology Measurements for Early Detection of Ongoing Hemorrhage
NCT04814810
Trauma Induced Coagulopathy and Inflammation
NCT03128658
Pre-Hospital Use of Plasma for Traumatic Hemorrhage
NCT02303964
An Observational Study of Early Coagulopathy, or Clotting Disorder, in Injured Patients
NCT00744003
Non-invasive Hemodynamic Monitoring During Blood Donation for Developing Models of Early Blood Loss
NCT01448694
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
This is not a therapeutic study. The main outcome variables are non-invasive measurements that will be used for machine learning, not real-time patient management. The data generated will be used later for discovery and validation in traditional and innovative machine learning.
As a minimal risk study, there will be no change from standard of care for patients undergoing surgery. The surgical procedures and pharmacotherapies will proceed as per standard clinical management.
Enrolled patients will undergo standard preoperative, anesthetic, and postoperative physiological monitoring that includes:
Electrocardiogram: Heart rate and electrical activity of the heart will be recorded via a 3-lead ECG.
Arterial Oxygen Saturation (SpO2): Pulse oximetry will be recorded using a commercially available finger pulse oximeter.
Finger Photoplethysmography: waveforms will be obtained non-invasively from either the SpO2 photoplethysmography or alternatively a Flashback Technologies Compensatory Reserve Index (CRI™) device.
In addition to these standard physiologic measurements, as a part of the research, the investigators will also acquire the following non-invasive optical and impedance measurements. All of these devices have been previously validated as non-invasive and safe in humans. The impedance electrodes and optical emitter/detectors will be incorporated into easily applied latex-free based "belts" that will be applied to anatomic locations along the thorax, abdomen and thigh. Application of these belts will be as soon as practical after patient arrival.
The clinicians providing care to the patient will be blind with respect to the measurements from these devices.
Continuous-wave Near-Infrared Spectroscopy (CW-NIRS) Device, custom built:
The device is built on an Ocean Optics FLAME USB Spectrometers, with two OSRAM 4736 NIR LEDs in plastic holders meant to be taped or strapped to the patient on the chest/torso and thigh locations. An Oceans Optics tungsten-halogen light source is used for an additional probe location on the forehead. Probe holders are designed to collect light from surface of skin by means of a mirror and collimator. The device will collect data on light attenuation of muscle in models of shock/trauma. The light output for all locations is below the ANSI limits for maximum permissible skin exposure.
SwissTom Electrical Impedance Tomography (EIT) System:
Name of device: Pioneer Set (Electrical Impedance Tomography System) Device Manufacturer: SwissTom AG (Parent company SenTec AG)
This device monitors dynamically changing perfusion physiology. To record multiplexed impedance signature a belt of 16-32 electrodes is placed around the thorax above the nipple line and thigh and impedances are recorded between multiple sets of electrodes.
SwissTom develops a clinical EIT system that is approved for pulmonary imaging. This Pioneer system is their research platform that has similar functionality and safety performance to their clinical system but provides research teams with access to raw data and additional functionality for specifying imaging parameters (e.g. control of frame rates, signal frequency acquisition, electrode drive patterns).
ScioSpec MultiChannel Electrical Impedance Spectroscopy (EIS) System:
Name of device: ISX-Mini (MultiChannel Electrical Impedance Spectroscopy System) Device Manufacturer: ScioSpec
To record multiplexed impedance signatures- an array of 4 electrodes is placed around the cranium and thorax of the patient and impedance spectroscopy signatures are recorded at each anatomic location. This device monitors dynamically changing intracranial, intrathoracic and intra-abdominal physiology.
General Approach to Minimize Risk:
This protocol will be minimal risk to patients as there is little risk associated with the placement of these devices and they can be removed at any time. They don't interfere with standard equipment used in clinical management of trauma patients.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
NA
SINGLE_GROUP
DIAGNOSTIC
NONE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
Trauma Patients
Patients suffering blunt and/or penetrating trauma but without physiologic criteria suggestive of ongoing hemorrhage:
1. Awake and alert GCS \>14
2. Admission systolic blood pressure greater than 90 and heart rate less than 120
3. Without signs of clinically significant ongoing external hemorrhage with no active bleeding documented on radiology/ultrasound and stable vital signs (no signs of hemodynamic deterioration) during initial evaluation (approximately 15 minutes post admission)
Detection of Occult Hemorrhage in Trauma Patients
Non-invasive monitoring of trauma patients
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
Detection of Occult Hemorrhage in Trauma Patients
Non-invasive monitoring of trauma patients
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
2. Admission systolic blood pressure greater than 90 and heart rate less than 120
3. Without signs of clinically significant ongoing external hemorrhage with no active bleeding documented on radiology/ultrasound and stable vital signs (no signs of hemodynamic deterioration) during initial evaluation (approximately 15 minutes post admission)
Exclusion Criteria
2. Systolic blood pressure less than 90 or heart rate greater than 120
3. Need for ongoing fluid or pressor support (standard local fluid resuscitation only)
4. Clinically significant ongoing external hemorrhage
5. Respiratory distress with O2 saturation \<96%
6. Pre-existing systemic illness, likely to alter systemic cardiovascular response to hemorrhage (overt clinical heart failure). Including congestive heart failure, and a paced cardiac rhythm.
7. Pregnant
8. Prisoner status
18 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
United States Department of Defense
FED
Dartmouth College
OTHER
Baystate Medical Center
OTHER
Dartmouth-Hitchcock Medical Center
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
Noman Paradis, MD
Role: PRINCIPAL_INVESTIGATOR
Dartmouth-Hitchcock Medical Center
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Baystate Medical Center
Springfield, Massachusetts, United States
Countries
Review the countries where the study has at least one active or historical site.
References
Explore related publications, articles, or registry entries linked to this study.
Shackelford SA, Colton K, Stansbury LG, Galvagno SM Jr, Anazodo AN, DuBose JJ, Hess JR, Mackenzie CF. Early identification of uncontrolled hemorrhage after trauma: current status and future direction. J Trauma Acute Care Surg. 2014 Sep;77(3 Suppl 2):S222-7. doi: 10.1097/TA.0000000000000198. No abstract available.
Parks JK, Elliott AC, Gentilello LM, Shafi S. Systemic hypotension is a late marker of shock after trauma: a validation study of Advanced Trauma Life Support principles in a large national sample. Am J Surg. 2006 Dec;192(6):727-31. doi: 10.1016/j.amjsurg.2006.08.034.
Wo CC, Shoemaker WC, Appel PL, Bishop MH, Kram HB, Hardin E. Unreliability of blood pressure and heart rate to evaluate cardiac output in emergency resuscitation and critical illness. Crit Care Med. 1993 Feb;21(2):218-23. doi: 10.1097/00003246-199302000-00012.
Convertino VA, Moulton SL, Grudic GZ, Rickards CA, Hinojosa-Laborde C, Gerhardt RT, Blackbourne LH, Ryan KL. Use of advanced machine-learning techniques for noninvasive monitoring of hemorrhage. J Trauma. 2011 Jul;71(1 Suppl):S25-32. doi: 10.1097/TA.0b013e3182211601.
Convertino VA. Blood pressure measurement for accurate assessment of patient status in emergency medical settings. Aviat Space Environ Med. 2012 Jun;83(6):614-9. doi: 10.3357/asem.3204.2012.
Kim SH, Lilot M, Sidhu KS, Rinehart J, Yu Z, Canales C, Cannesson M. Accuracy and precision of continuous noninvasive arterial pressure monitoring compared with invasive arterial pressure: a systematic review and meta-analysis. Anesthesiology. 2014 May;120(5):1080-97. doi: 10.1097/ALN.0000000000000226.
Soller BR, Yang Y, Soyemi OO, Ryan KL, Rickards CA, Walz JM, Heard SO, Convertino VA. Noninvasively determined muscle oxygen saturation is an early indicator of central hypovolemia in humans. J Appl Physiol (1985). 2008 Feb;104(2):475-81. doi: 10.1152/japplphysiol.00600.2007. Epub 2007 Nov 15.
Belle A, Ansari S, Spadafore M, Convertino VA, Ward KR, Derksen H, Najarian K. A Signal Processing Approach for Detection of Hemodynamic Instability before Decompensation. PLoS One. 2016 Feb 12;11(2):e0148544. doi: 10.1371/journal.pone.0148544. eCollection 2016.
Provided Documents
Download supplemental materials such as informed consent forms, study protocols, or participant manuals.
Document Type: Study Protocol and Statistical Analysis Plan
Document Type: Informed Consent Form
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
STUDY02001495
Identifier Type: -
Identifier Source: org_study_id
More Related Trials