Multicentered Prospective Randomized Controlled Trial For Solid Pancreatic Lesions

NCT ID: NCT04841616

Last Updated: 2023-02-13

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

UNKNOWN

Clinical Phase

NA

Total Enrollment

128 participants

Study Classification

INTERVENTIONAL

Study Start Date

2021-07-01

Study Completion Date

2025-06-30

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

Endoscopic ultrasound (EUS) is an indispensable tool for tissue acquisition for pancreatic lesions. Fine needle aspiration (FNA) is once considered as the first line diagnostic method especially when rapid on-site evaluation (ROSE) by cytopathologist is available.

However, FNA alone has several limitations including inadequate acquisition of cells, and unable to provide core tissue for further histological analysis. Furthermore, ROSE is not available in many endoscopic centres due to limited resources. Endosonographers around the world, are discovering methods to overcome the limitations, including the use of new on-site evaluation technique by endoscopists, new fine-needle biopsy (FNB) needles, contrast-enhanced harmonic EUS-guided FNB.

In this study, the investigators propose to compare the diagnostic performance between contrast-enhanced EUS-guided FNB versus conventional EUS-guided FNB technique with an aim to define the best EUS-guided tissue acquisition technique in the absence of ROSE. Results obtained from this research is expected to have significant impact in providing new insights on the best EUS-guided tissue acquisition method. It may replace FNA with ROSE as the gold standard for EUS-guided tissue acquisition in an affordable manner. It will also save the patients from unnecessary procedures and fasten the treatment pathways.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

Seicean et al, in a prospective study, evaluated the diagnostic accuracy of EUS-FNA with CH-EUS using SonoVueTM versus EUS-FNA without CH-EUS. They found that the diagnostic accuracy of EUS-FNA with CH-EUS was higher than that of EUSFNA without CH-EUS (86.5% vs 78.4%). However, the difference did not reach the threshold required for statistical significance. Also, only FNA, but not FNB, was performed in this study.

The FNB needle was introduced to further improve upon EUS guided tissue sampling. It is designed to collect a larger amount of core sample tissue with preserved histological architecture for further analysis, including molecular analysis. Also the FNB needle has been shown to obtain samples with higher cellularity compared to the standard FNA needles. Compared with EUS-FNA, EUS-FNB had a better specimen adequacy, higher diagnostic accuracy, and fewer number of needle passes but no increase in complications rate.

The technique of macroscopic on-site evaluation (MOSE) has recently been advocated for estimating the adequacy of a core specimen obtained by EUS for histological diagnosis. MOSE involves immediate examination of the FNB specimen for the presence of a "macroscopic visible core" (MVC), which is defined as whitish or yellowish pieces of tissue with an apparent bulk. The total length of the MVC is then measured and the optimal cut-off MVC length was 4 mm. This study demonstrated that EUS-FNB with MOSE provided comparable diagnostic yield as EUS-FNB without MOSE (92.6% vs 89.3%) with fewer numbers of passes.

Puncturing avascular or necrotic area of a tumour could be the major reason of false negative rate during EUS-guided FNB. Contrast-enhanced harmonic EUS (CH-EUS) can define avascular or necrotic area inside a tumour which may improve the false negative rate during EUS-FNB. In this study, the investigators aim to evaluate the diagnostic performance of CH-EUS-guided FNB with MOSE for solid pancreatic masses. The investigators expect the study will define the best EUS-guided tissue acquisition technique in the absence of ROSE and replace FNA with ROSE as gold standard for tissue sampling for solid pancreatic masses.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Pancreas Neoplasm

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Allocation Method

RANDOMIZED

Intervention Model

PARALLEL

Primary Study Purpose

TREATMENT

Blinding Strategy

NONE

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

Contrast-enhanced EUS (CH-EUS) Arm

After initial evaluation, 2.5ml of second-generation contrast media, SonoVue (Bracco, Ceriano Laghetto, Italy), will be injected. After infusion, the point of puncture will be determined when the parenchyma of the pancreas was enhanced. The contrast-enhanced area was identified and then the biopsy was directed toward that area, while avoiding unenhanced (i.e. necrotic) areas and not changing the target lesion. Rest of the procedure is identical with that in conventional EUS arm.

Group Type EXPERIMENTAL

Contrast-Enhanced Harmonic Endoscopic Ultrasound

Intervention Type PROCEDURE

After initial evaluation, 2.5ml of second-generation contrast media, SonoVueTM (Bracco, Ceriano Laghetto, Italy), will be injected. After infusion, the point of puncture will be determined when the parenchyma of the pancreas was enhanced. The contrast-enhanced area was identified and then the biopsy was directed toward that area, while avoiding unenhanced (i.e. necrotic) areas and not changing the target lesion. Rest of the procedure is identical with that in conventional EUS arm.

Conventional EUS Arm

Patients will undergo EUS FNB with the 22-gauge FNB needle (Acquire®, Boston Scientific Natick, MA). After each pass, the needle is removed and the stylet will be introduced into the needle to extrude any aspirated material on a glass slide for inspection of the presence of a macroscopic visible core (MVC). The total length of the MVC will be measured before placement into a formalin bottle. EUS-FNB is completed if the obtained MVC is longer than 4mm and deemed adequate by endoscopist. If the obtained MVC is \< 4mm, the procedure is repeated until a MVC of ≥ 4mm is obtained and deemed adequate by endoscopist. A maximum of 7 passes is allowed

Group Type ACTIVE_COMPARATOR

Endoscopic Ultrasound -Guided Fine Needle Biopsy

Intervention Type PROCEDURE

Patients will undergo EUS FNB with the 22-gauge FNB needle (Acquire®, Boston Scientific Natick, MA). After each pass, the needle is removed and the stylet will be introduced into the needle to extrude any aspirated material on a glass slide for inspection of the presence of a macroscopic visible core (MVC). The total length of the MVC will be measured before placement into a formalin bottle. EUS-FNB is completed if the obtained MVC is longer than 4mm and deemed adequate by endoscopist. If the obtained MVC is \< 4mm, the procedure is repeated until a MVC of ≥ 4mm is obtained and deemed adequate by endoscopist. A maximum of 7 passes is allowed.

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

Endoscopic Ultrasound -Guided Fine Needle Biopsy

Patients will undergo EUS FNB with the 22-gauge FNB needle (Acquire®, Boston Scientific Natick, MA). After each pass, the needle is removed and the stylet will be introduced into the needle to extrude any aspirated material on a glass slide for inspection of the presence of a macroscopic visible core (MVC). The total length of the MVC will be measured before placement into a formalin bottle. EUS-FNB is completed if the obtained MVC is longer than 4mm and deemed adequate by endoscopist. If the obtained MVC is \< 4mm, the procedure is repeated until a MVC of ≥ 4mm is obtained and deemed adequate by endoscopist. A maximum of 7 passes is allowed.

Intervention Type PROCEDURE

Contrast-Enhanced Harmonic Endoscopic Ultrasound

After initial evaluation, 2.5ml of second-generation contrast media, SonoVueTM (Bracco, Ceriano Laghetto, Italy), will be injected. After infusion, the point of puncture will be determined when the parenchyma of the pancreas was enhanced. The contrast-enhanced area was identified and then the biopsy was directed toward that area, while avoiding unenhanced (i.e. necrotic) areas and not changing the target lesion. Rest of the procedure is identical with that in conventional EUS arm.

Intervention Type PROCEDURE

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

* referred for EUS-guided tissue acquisition for solid pancreatic lesions greater than 1cm in the largest diameter.

Exclusion Criteria

* with coagulopathy, altered anatomy, contraindications for conscious sedation, pregnancy
* who cannot provide informed consent.
Minimum Eligible Age

18 Years

Maximum Eligible Age

80 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

No

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

Chinese University of Hong Kong

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Charing Chong, MD

Dr

Responsibility Role PRINCIPAL_INVESTIGATOR

Principal Investigators

Learn about the lead researchers overseeing the trial and their institutional affiliations.

Ching Ning Chong

Role: PRINCIPAL_INVESTIGATOR

CUHK

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

Department of Surgery; The Chinese University of Hong Kong

Hong Kong, , Hong Kong

Site Status RECRUITING

Countries

Review the countries where the study has at least one active or historical site.

Hong Kong

Central Contacts

Reach out to these primary contacts for questions about participation or study logistics.

Ching Ning Chong

Role: CONTACT

Facility Contacts

Find local site contact details for specific facilities participating in the trial.

Charing C Chong, MBChB

Role: primary

852-26321496

References

Explore related publications, articles, or registry entries linked to this study.

Strand DS, Jeffus SK, Sauer BG, Wang AY, Stelow EB, Shami VM. EUS-guided 22-gauge fine-needle aspiration versus core biopsy needle in the evaluation of solid pancreatic neoplasms. Diagn Cytopathol. 2014 Sep;42(9):751-8. doi: 10.1002/dc.23116. Epub 2014 Feb 18.

Reference Type BACKGROUND
PMID: 24550162 (View on PubMed)

Aadam AA, Wani S, Amick A, Shah JN, Bhat YM, Hamerski CM, Klapman JB, Muthusamy VR, Watson RR, Rademaker AW, Keswani RN, Keefer L, Das A, Komanduri S. A randomized controlled cross-over trial and cost analysis comparing endoscopic ultrasound fine needle aspiration and fine needle biopsy. Endosc Int Open. 2016 May;4(5):E497-505. doi: 10.1055/s-0042-106958.

Reference Type BACKGROUND
PMID: 27227104 (View on PubMed)

Lee YN, Moon JH, Kim HK, Choi HJ, Choi MH, Kim DC, Lee TH, Cha SW, Cho YD, Park SH. Core biopsy needle versus standard aspiration needle for endoscopic ultrasound-guided sampling of solid pancreatic masses: a randomized parallel-group study. Endoscopy. 2014 Dec;46(12):1056-62. doi: 10.1055/s-0034-1377558. Epub 2014 Aug 6.

Reference Type BACKGROUND
PMID: 25098611 (View on PubMed)

Iwashita T, Yasuda I, Mukai T, Doi S, Nakashima M, Uemura S, Mabuchi M, Shimizu M, Hatano Y, Hara A, Moriwaki H. Macroscopic on-site quality evaluation of biopsy specimens to improve the diagnostic accuracy during EUS-guided FNA using a 19-gauge needle for solid lesions: a single-center prospective pilot study (MOSE study). Gastrointest Endosc. 2015 Jan;81(1):177-85. doi: 10.1016/j.gie.2014.08.040. Epub 2014 Oct 29.

Reference Type BACKGROUND
PMID: 25440688 (View on PubMed)

Seicean A, Badea R, Moldovan-Pop A, Vultur S, Botan EC, Zaharie T, Saftoiu A, Mocan T, Iancu C, Graur F, Sparchez Z, Seicean R. Harmonic Contrast-Enhanced Endoscopic Ultrasonography for the Guidance of Fine-Needle Aspiration in Solid Pancreatic Masses. Ultraschall Med. 2017 Apr;38(2):174-182. doi: 10.1055/s-0035-1553496. Epub 2015 Aug 14.

Reference Type BACKGROUND
PMID: 26274382 (View on PubMed)

Fuccio L, Larghi A. Endoscopic ultrasound-guided fine needle aspiration: How to obtain a core biopsy? Endosc Ultrasound. 2014 Apr;3(2):71-81. doi: 10.4103/2303-9027.123011.

Reference Type BACKGROUND
PMID: 24955336 (View on PubMed)

Iglesias-Garcia J, Poley JW, Larghi A, Giovannini M, Petrone MC, Abdulkader I, Monges G, Costamagna G, Arcidiacono P, Biermann K, Rindi G, Bories E, Dogloni C, Bruno M, Dominguez-Munoz JE. Feasibility and yield of a new EUS histology needle: results from a multicenter, pooled, cohort study. Gastrointest Endosc. 2011 Jun;73(6):1189-96. doi: 10.1016/j.gie.2011.01.053. Epub 2011 Mar 21.

Reference Type BACKGROUND
PMID: 21420083 (View on PubMed)

Yang MJ, Yim H, Hwang JC, Lee D, Kim YB, Lim SG, Kim SS, Kang JK, Yoo BM, Kim JH. Endoscopic ultrasound-guided sampling of solid pancreatic masses: 22-gauge aspiration versus 25-gauge biopsy needles. BMC Gastroenterol. 2015 Sep 29;15:122. doi: 10.1186/s12876-015-0352-9.

Reference Type BACKGROUND
PMID: 26419845 (View on PubMed)

Kin T, Katanuma A, Yane K, Takahashi K, Osanai M, Takaki R, Matsumoto K, Gon K, Matsumori T, Tomonari A, Maguchi H, Shinohara T, Nojima M. Diagnostic ability of EUS-FNA for pancreatic solid lesions with conventional 22-gauge needle using the slow pull technique: a prospective study. Scand J Gastroenterol. 2015 Jul;50(7):900-7. doi: 10.3109/00365521.2014.983155. Epub 2015 Mar 2.

Reference Type BACKGROUND
PMID: 25732902 (View on PubMed)

Teoh AYB, Serna C, Penas I, Chong CCN, Perez-Miranda M, Ng EKW, Lau JYW. Endoscopic ultrasound-guided gallbladder drainage reduces adverse events compared with percutaneous cholecystostomy in patients who are unfit for cholecystectomy. Endoscopy. 2017 Feb;49(2):130-138. doi: 10.1055/s-0042-119036. Epub 2016 Nov 22.

Reference Type BACKGROUND
PMID: 27875855 (View on PubMed)

Teoh AY, Ng EK, Chan SM, Lai M, Moran S, Binmoeller KF, Moon JH, Ho KY. Ex vivo comparison of the lumen-apposing properties of EUS-specific stents (with video). Gastrointest Endosc. 2016 Jul;84(1):62-8. doi: 10.1016/j.gie.2015.11.041. Epub 2015 Dec 10.

Reference Type BACKGROUND
PMID: 26684601 (View on PubMed)

Teoh AYB, Chong CCN, Leung WW, Chan SKC, Tse YK, Ng EKW, Lai PBS, Wu JCY, Lau JYW. Electroacupuncture-reduced sedative and analgesic requirements for diagnostic EUS: a prospective, randomized, double-blinded, sham-controlled study. Gastrointest Endosc. 2018 Feb;87(2):476-485. doi: 10.1016/j.gie.2017.07.029. Epub 2017 Jul 24.

Reference Type BACKGROUND
PMID: 28750840 (View on PubMed)

Chong CCN, Tang RSY, Wong JCT, Chan AWH, Teoh AYB. Endoscopic ultrasound of pancreatic lesions. J Vis Surg. 2016 Jul 22;2:119. doi: 10.21037/jovs.2016.07.10. eCollection 2016.

Reference Type BACKGROUND
PMID: 29399505 (View on PubMed)

Teoh AY, Chong CC, Chan AW, Lau JY. EUS-guided alcohol injection of pancreatic neuroendocrine tumor. Gastrointest Endosc. 2015 Jul;82(1):167. doi: 10.1016/j.gie.2015.01.047. Epub 2015 Apr 22. No abstract available.

Reference Type BACKGROUND
PMID: 25910658 (View on PubMed)

Chong CCN, Teoh AYB, Tang RSY, Chan AWH, Ng EKW, Lai PBS. EUS-FNA using 22G nitinol or ProCore needles without on-site cytopathology. Endosc Ultrasound. 2018 Jan-Feb;7(1):56-60. doi: 10.4103/eus.eus_113_17.

Reference Type BACKGROUND
PMID: 29451170 (View on PubMed)

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

CREC2020.496

Identifier Type: -

Identifier Source: org_study_id

More Related Trials

Additional clinical trials that may be relevant based on similarity analysis.

Diagnostic Efficacy Of 3 EUS-FNB Techniques
NCT05825729 RECRUITING PHASE4