Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
COMPLETED
NA
59 participants
INTERVENTIONAL
2021-04-21
2022-06-01
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
AED-delivery Using Drones in Out-of-hospital Cardiac Arrest
NCT04415398
Referral of Callers to Retrieve Drone-delivered AEDs in Out-of-hospital Cardiac Arrest
NCT05391256
Developing and Testing Drone-Delivered AEDs for Cardiac Arrests In Rural America
NCT06229418
The Scandinavian AED and Mobile Bystander Activation Trial
NCT02992873
Early Double Sequential Defibrillation in Out of Hospital Cardiac Arrest
NCT07174986
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
Totally, five AED-equipped drones will be placed in hangars at five different sites covering a geographic area of about 200 km2 and approximately 125,000 inhabitants for dispatch to suspected cases of OHCA as a complement to standard care i.e., ambulance. By coordinating the operations with local Air Traffic Control (ATC), the risk of airspace conflicts, or in worst case collisions, is mitigated to an acceptable level.
The investigators estimate to enroll some 80 alerts and 60 participants during a study period of up to 14 months. The investigators will closely follow and study the potential of delivering AEDs prior ambulance arrival and timesaving effects as compared to ambulance during a period of up to 14 months in which the investigators will follow and study the potential of delivering AEDs prior ambulance arrival and timesaving effects as compared to ambulance.
The drone operator, Everdrone, has integrated all software and hardware for the concept on the DJI Matrice 600 Pro drone. Examples of added features: an integrated Parachute Rescue System (validated by independent third party using the ASTM F3322 - 18 standard), a high precision sense and avoid system and a winching device to safely lower the AED to ground at delivery. Furthermore, Everdrone AB has fully integrated their system and operational routines with the dispatch central, emergency medical services and aviation organizations. As a result from the previous study (version 1.0) a number of hardware and software improvements have been made to the system (version 2.0):
Five hangars will be setup at optimal locations in each of the five administrative areas. Hangars are large isolated tents 4x4 meters in where the drone is placed, remotely operated and surveiled by camera. Hangars are within fenced areas so that the public has no access. They are equipped with weather stations and an automated gate which automatically will open on alert.
When an emergency 112-call is answered it is indexed by the dispatcher depending on the patients condition. If an OHCA is suspected, the dispatcher indexes the event as a)"ongoing cardio-pulmonary resuscitation (CPR)" or b) "Unconscious with abnormal or absent breathing". If an emergency call is identified within administrative areas AND indexed as "a" or "b" an automated (not manual as with ambulance alerts) alert is sent via radio-alert to the drone operator. This triggers:
* boot-up of the drone
* drone hangar gate opening
* route-planning of the mission
* weather condition confirmation
* remote pilot acceptance of the mission
* remote pilot calling ATC for takeoff approval
The drone system receives an alert from the dispatch center and the drone takes off from the hangar after approval from the drone pilot. For safety reasons all beyond visual line of sight (BVLOS) flights are done within the controlled airspace of Säve airport approval from ATC granted for every single flight. Each flight will be carried out at 60-80 meters of altitude, have a preliminary maximum flight speed of 70 km/h, and a maximum range of 6 km one-way. The drone system is remotely deployed and surveiled from the drone operating center at Everdrone Säve Airport, the drone is dispatched alongside ambulance as a complement to standard care. The drone systems are designed to operate in dry conditions with median winds not exceeding 8 m/s and primarily during daylight conditions.
The AED used is an ultra-light AED (FRED Easyport from Schiller), weighting totally 800 grams with basket and siren. Upon arrival onsite the basket with the AED will be winched down from about 30 m altitude and delivered within 10 meters from the object i.e., the front door or onsite in public areas. Local AED drone support after completed mission includes electrode change battery test, potentially pic-up up the drone after dispatch by the Everdrone personnel.
Dispatch of the drone in suspected OHCA cases will be executed as a complement to standard care i.e., ambulance between 21 April to 1 June 2022, totally up to 14 months of full-scale real-life flights to suspected OHCA victims. Based on historical data of OHCA from the Swedish register for cardiopulmonary resuscitation (SRCR) and first ever dispatch of AED-equipped drones during 2020 the drone systems will be alerted in an estimated 80 cases (about 3.5 flights/ week) of suspected OHCA over the study period. In about 25% of cases, predefined exclusion criteria (rain, median wind \> 8 m/s, high rise buildings \>20m, pre-flight checklists not OK) will presumably prohibit flights, thus making an estimated 60 cases eligible for inclusion (i.e., drone takes off to deliver AEDs in suspected OHCA.)
For more details about the methods please see the research protocol.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
NA
SINGLE_GROUP
TREATMENT
NONE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
Automated flying Drone carrying an Automated external defibrillator (AED)
Five drone systems are setup to be deployed in suspected OHCA cases as a complement to EMS. This is a single-arm intervention evaluating time benefit of drone delivery of AEDs in suspected OHCA.
Automated flying Drone carrying an Automated external defibrillator (AED)
Totally n=5 drones are equipped with automated external defibrillators (AEDs). These drones are deployed by the dispatch centre to cases of suspected out-of-hospital cardiac (OHCA) as a complement to standard care (ambulance/EMS) over up to 14 months during daytime Monday to Sunday 08:00-22:00. The bystander onsite receives instructions from the dispatcher to retrieve the AED outside the house when it has been delivered by the drone. The bystander attaches the AED to the patients chest to facilitate early defibrillation.
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
Automated flying Drone carrying an Automated external defibrillator (AED)
Totally n=5 drones are equipped with automated external defibrillators (AEDs). These drones are deployed by the dispatch centre to cases of suspected out-of-hospital cardiac (OHCA) as a complement to standard care (ambulance/EMS) over up to 14 months during daytime Monday to Sunday 08:00-22:00. The bystander onsite receives instructions from the dispatcher to retrieve the AED outside the house when it has been delivered by the drone. The bystander attaches the AED to the patients chest to facilitate early defibrillation.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
* Within prespecified administrative areas (excluding no delivery- and no-fly zones)
* Hours of operation: 08:00-22:00 (daylight conditions)
* Drone system online
Exclusion Criteria
* Children \<8 years
* Trauma
* EMS-witnessed cases
Post alert:
* ATC non-approval of flight
* Rain, winds exceeding 8m/s (median)
8 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
SOS Alarm Sverige AB
UNKNOWN
Everdrone AB
UNKNOWN
Vastra Gotaland Region
OTHER_GOV
Aviation capacity resources AB (ACR)
UNKNOWN
Castellum AB
UNKNOWN
Karolinska Institutet
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Andreas Claesson
RN, Associate professor
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Center for Resuscitation science
Stockholm, , Sweden
Countries
Review the countries where the study has at least one active or historical site.
References
Explore related publications, articles, or registry entries linked to this study.
Schierbeck S, Nord A, Svensson L, Ringh M, Nordberg P, Hollenberg J, Lundgren P, Folke F, Jonsson M, Forsberg S, Claesson A. Drone delivery of automated external defibrillators compared with ambulance arrival in real-life suspected out-of-hospital cardiac arrests: a prospective observational study in Sweden. Lancet Digit Health. 2023 Dec;5(12):e862-e871. doi: 10.1016/S2589-7500(23)00161-9.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
SS1
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.